SE-ACNSE-ACN Nozzle AC Antistatic Bar
AC ionization plus high-velocity air jets — removes dust and separates static-stuck parts in one step
The FÖGE SE-DCN is a pulsed DC nozzle antistatic bar that combines pulsed DC ionization with a row of high-velocity air nozzles along the bar body. Like the SE-ACN it is a dual-function device: it neutralises the electrostatic charge on the target surface and delivers a focused air blast — either to blow away the dust and particles the static was holding, or to provide the force needed to separate parts that stick together.
The difference from the SE-ACN is the ionization technology. The SE-DCN generates its 11 kV pulsed DC ionization internally from a 24 V DC supply — no HV transformer, no HV cabling and no SE-PAC power unit. It connects to the SE-PSU-24-C-M12 power supply (sold separately) via an M12 connector, which makes it easy to integrate into machine controls, robotic installations and 24 V DC production lines. Compressed air is required at the installation point.

The SE-DCN connects to a 24 V DC supply via its M12 connector. The pulsed DC circuit inside the bar converts the 24 V input to high voltage and applies it to the tungsten emitter pins, alternating continuously between positive and negative pulses to produce a balanced stream of ions. Compressed air connected to the bar's air inlets flows through the manifold and out of focused nozzles along the bar body. At the target, the ions neutralise the charge and the air blast removes contamination or provides the separation force.
Neutralise the charge holding dust, fibres and particles and blow them away — a clean, static-free surface before printing, coating, laminating or inspection.
Neutralise the static that makes parts stick to moulds or sheets cling together, while the air blast separates them.
No SE-PAC, no HV cabling — the same supply standard as the SE-DCB and SE-DCA bars.
| Parameter | SE-DCN (this product) | SE-ACN |
|---|---|---|
| Ionization | Pulsed DC, 11 kV | AC, 5.5 kV or 8 kV |
| Power supply | 24 V DC (SE-PSU-24-C-M12) | SE-PAC-55 or SE-PAC-80 HV unit |
| HV power unit | Not required | Required |
| Connector | M12 (4-pin cable) | HV plug-and-play connector |
| Air required | Yes | Yes |
| Applications | Description |
|---|---|
| Printing press & sheet feeder — sheet separation | Neutralise static between sheets while the air blast separates the top sheet from the stack. |
| Injection moulding — mould release | Neutralise freshly moulded parts while the air blast assists ejection and cleans the mould face. |
| Pre-print & pre-coat surface cleaning | Remove dust, fibres and particles from paper, film, board and plastic before printing, coating or varnishing. |
| Pre-laminating & pre-bonding cleaning | Remove static and contamination before adhesive application, laminating or bonding. |
| Thermoformed part separation | Separate trays, blisters and packaging components that cling together. |
| Electronic component & PCB cleaning | Remove particles from PCBs and assemblies before assembly or inspection. |
Don't know the exact voltage, distance and speed on your line? Talk to our application engineers — we will calculate the antistatic configuration for your project within 1 working day.
| Parameter | Specification |
|---|---|
| Product code | SE-DCN-110-xxxx-C |
| Length for ordering | 300 – 2000 mm |
| Operating voltage | 24 V DC (21 – 28 V) |
| Power supply (sold separately) | SE-PSU-24-C-M12 (220 V AC to 24 V DC) |
| Connector | M12, 5-pin — use a 4-pin M12 cable |
| Ionization | Pulsed DC · 11 kV · shockless |
| Ionization range | Up to 600 mm |
| Air connection | 10 mm hose |
| Air pressure — dry filtered air | 6 bar |
| Emitter pin material | Tungsten — long life |
| Status indication | Signal LED |
| Mounting | M6 mounting bracket · ground terminal |
| Polarity | Alternating pulsed DC — balanced ion output |
| Environment | 0 – 55 °C · 70 % rH non-condensing max. · IP66, fully sealed (with suitable cable) |
| Safety | Shockless, pin current < 250 μA |
| EMC compliance | 2014/30/EU — EMC Directive |
| Electrical safety | 2014/35/EU — Low Voltage Directive |

| Component | Description |
|---|---|
| SE-DCN bar (specify length) | 300 – 2000 mm |
| SE-PSU-24-C-M12 power supply | 220 V AC to 24 V DC — required · sold separately |
| 4-pin M12 cable | Industrial M12 connection cable · sold separately |
| Compressed air supply | Dry, filtered air at 6 bar via 10 mm hose |
Both bars ionize + clean and ionize + separate with the same nozzle principle. The SE-DCN uses 11 kV pulsed DC from a 24 V DC supply; the SE-ACN uses AC ionization from an SE-PAC HV power unit.
No. The ionization is generated inside the bar from 24 V DC. The SE-PSU-24-C-M12 adapter is required and sold separately.
A 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable.
Yes. Use dry, filtered air at 6 bar through a 10 mm hose.
High-voltage equipment. Installation and maintenance by qualified personnel only, following the operating manual. Safety & compliance
SE-ACNAC ionization plus high-velocity air jets — removes dust and separates static-stuck parts in one step
SE-DCA-110Long-range static elimination up to 1000 mm — compressed air-assisted ionization, 24 V DC, no HV transformer
SE-DCB-110Long-range static elimination at 100 – 600 mm — 11 kV pulsed DC, 24 V DC supply, no HV transformer