SE-DCN-110 Pulsed DC Nozzle Antistatic Bar

Pulsed DC static elimination plus high-velocity air jets — dust removal, sheet separation and mould release from 24 V DC

Overview

The FÖGE SE-DCN is a pulsed DC nozzle antistatic bar that combines pulsed DC ionization with a row of high-velocity air nozzles along the bar body. Like the SE-ACN it is a dual-function device: it neutralises the electrostatic charge on the target surface and delivers a focused air blast — either to blow away the dust and particles the static was holding, or to provide the force needed to separate parts that stick together.

The difference from the SE-ACN is the ionization technology. The SE-DCN generates its 11 kV pulsed DC ionization internally from a 24 V DC supply — no HV transformer, no HV cabling and no SE-PAC power unit. It connects to the SE-PSU-24-C-M12 power supply (sold separately) via an M12 connector, which makes it easy to integrate into machine controls, robotic installations and 24 V DC production lines. Compressed air is required at the installation point.

Key features

  • Dual function: pulsed DC ionization + high-velocity air jets
  • 11 kV pulsed DC — no HV power unit required
  • 24 V DC supply via M12 connector (4-pin M12 cable)
  • Ionization range up to 600 mm
  • Removes dust and contamination or separates static-stuck parts
  • Tungsten emitter pins · shockless design
  • Signal LED for status display
  • Lengths from 300 to 2000 mm · IP66

Request technical quoteDownload datasheet (PDF)

SE-DCN pulsed DC nozzle antistatic bar: yellow ionizing bar with air manifold, three conical air nozzles, ground cable and elbow air fittings

Industries

  • Printing & converting
  • Plastics & injection moulding
  • Packaging & thermoforming
  • Electronics
  • Paper & board
  • Automotive (plastic parts)

How it works

The SE-DCN connects to a 24 V DC supply via its M12 connector. The pulsed DC circuit inside the bar converts the 24 V input to high voltage and applies it to the tungsten emitter pins, alternating continuously between positive and negative pulses to produce a balanced stream of ions. Compressed air connected to the bar's air inlets flows through the manifold and out of focused nozzles along the bar body. At the target, the ions neutralise the charge and the air blast removes contamination or provides the separation force.

Advantages & benefits

  1. Ionize + clean

    Neutralise the charge holding dust, fibres and particles and blow them away — a clean, static-free surface before printing, coating, laminating or inspection.

  2. Ionize + separate

    Neutralise the static that makes parts stick to moulds or sheets cling together, while the air blast separates them.

  3. 24 V DC simplicity

    No SE-PAC, no HV cabling — the same supply standard as the SE-DCB and SE-DCA bars.

SE-DCN or SE-ACN — which nozzle bar to choose

ParameterSE-DCN (this product)SE-ACN
IonizationPulsed DC, 11 kVAC, 5.5 kV or 8 kV
Power supply24 V DC (SE-PSU-24-C-M12)SE-PAC-55 or SE-PAC-80 HV unit
HV power unitNot requiredRequired
ConnectorM12 (4-pin cable)HV plug-and-play connector
Air requiredYesYes

Applications

ApplicationsDescription
Printing press & sheet feeder — sheet separationNeutralise static between sheets while the air blast separates the top sheet from the stack.
Injection moulding — mould releaseNeutralise freshly moulded parts while the air blast assists ejection and cleans the mould face.
Pre-print & pre-coat surface cleaningRemove dust, fibres and particles from paper, film, board and plastic before printing, coating or varnishing.
Pre-laminating & pre-bonding cleaningRemove static and contamination before adhesive application, laminating or bonding.
Thermoformed part separationSeparate trays, blisters and packaging components that cling together.
Electronic component & PCB cleaningRemove particles from PCBs and assemblies before assembly or inspection.

See it in a 3D application

Not sure about voltage, distance or line speed?

Don't know the exact voltage, distance and speed on your line? Talk to our application engineers — we will calculate the antistatic configuration for your project within 1 working day.

Ask an application engineerDownload datasheet (PDF)

Technical specifications

SE-DCN-110 Technical specifications
ParameterSpecification
Product codeSE-DCN-110-xxxx-C
Length for ordering300 – 2000 mm
Operating voltage24 V DC (21 – 28 V)
Power supply (sold separately)SE-PSU-24-C-M12 (220 V AC to 24 V DC)
ConnectorM12, 5-pin — use a 4-pin M12 cable
IonizationPulsed DC · 11 kV · shockless
Ionization rangeUp to 600 mm
Air connection10 mm hose
Air pressure — dry filtered air6 bar
Emitter pin materialTungsten — long life
Status indicationSignal LED
MountingM6 mounting bracket · ground terminal
PolarityAlternating pulsed DC — balanced ion output
Environment0 – 55 °C · 70 % rH non-condensing max. · IP66, fully sealed (with suitable cable)
SafetyShockless, pin current < 250 μA
EMC compliance2014/30/EU — EMC Directive
Electrical safety2014/35/EU — Low Voltage Directive

dimensional drawing

Dimensional drawing of the SE-DCN: overall length equals active length, air nozzles, ⌀ 10 mm compressed-air connections, ground terminal, M6 mounting bracket, cross-section 58.7 × 84.6 mm
Dimensional drawing of the SE-DCN: overall length equals active length, air nozzles, ⌀ 10 mm compressed-air connections, ground terminal, M6 mounting bracket, cross-section 58.7 × 84.6 mm

Complete system — what you need

ComponentDescription
SE-DCN bar (specify length)300 – 2000 mm
SE-PSU-24-C-M12 power supply220 V AC to 24 V DC — required · sold separately
4-pin M12 cableIndustrial M12 connection cable · sold separately
Compressed air supplyDry, filtered air at 6 bar via 10 mm hose

Frequently asked questions

What is the difference between the SE-DCN and the SE-ACN?

Both bars ionize + clean and ionize + separate with the same nozzle principle. The SE-DCN uses 11 kV pulsed DC from a 24 V DC supply; the SE-ACN uses AC ionization from an SE-PAC HV power unit.

Does the SE-DCN require an SE-PAC power unit?

No. The ionization is generated inside the bar from 24 V DC. The SE-PSU-24-C-M12 adapter is required and sold separately.

Which cable do I need?

A 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable.

Is compressed air required?

Yes. Use dry, filtered air at 6 bar through a 10 mm hose.

High-voltage equipment. Installation and maintenance by qualified personnel only, following the operating manual. Safety & compliance

Product catalogue