SE-DCB-90SE-DCB-90 Pulsed DC Antistatic Bar – 9 kV
Compact 9 kV pulsed DC static elimination — no HV transformer, 24 V DC supply, up to 200 mm range
The FÖGE SE-DCA-110 is a high-power 11 kV pulsed DC antistatic bar engineered for applications where standard ionizing bars cannot reach — delivering effective static elimination at distances up to 1000 mm through integrated compressed air assistance. By directing ionized air from the bar's nozzles at the target surface, the SE-DCA-110 extends its ionization reach far beyond what a passive bar can achieve. This makes it the right choice for film and plastic winding systems, injection mould cavities, automated conveyor lines, robotic handling systems and any installation where the bar must be positioned well away from the material surface.
Unlike traditional HV ionizing systems, the SE-DCA-110 operates at 24 V DC — the 11 kV ionization voltage is generated internally, eliminating the need for an external high-voltage transformer or high-voltage cabling. The only external connections required are a 24 V DC power supply (SE-PSU-24-C-M12, sold separately) and a standard compressed air line (⌀ 8 mm hose, minimum 2 bar, dry filtered). The bar is available with a straight (-S) or L-type 90° (-L) air fitting and can be ordered in any length from 300 mm to 2000 mm.

The SE-DCA-110 connects to a 24 V DC power supply (SE-PSU-24-C-M12) and a compressed air line. Internally, the bar's pulsed DC circuit generates 11 kV, which is applied to the tungsten emitter pins. The elevated voltage ionizes the air surrounding each pin, producing a dense, balanced cloud of positive and negative ions. Simultaneously, dry filtered compressed air is fed into the bar's integrated air channel and expelled through nozzles along the bar's length towards the target surface. This airflow picks up the ions generated at the pins and carries them at high velocity across the working distance, allowing effective static neutralisation at distances up to 1000 mm. The pulsed DC circuit alternates polarity continuously, keeping the ion output balanced and preventing net charge build-up on the target. The shockless design limits emitter pin current to a safe level at all times.
At up to 1000 mm, the SE-DCA-110 neutralises static on surfaces physically inaccessible to passive bars — inside mould cavities, on fast-moving webs at large air gaps, or on conveyors where close mounting is impossible.
Intense ion generation ensures fast, complete neutralisation even on heavily charged materials at the maximum working distance.
All 11 kV is generated inside the bar from a 24 V DC supply. No high-voltage cable runs, no transformer enclosure, no HV safety zones around cabling.
Order any length from 300 mm to 2000 mm — the bar spans exactly the width of the material or zone to be treated.
Where a straight hose connection is blocked by the machine structure, the 90° fitting solves the problem without adapters or bends.
At 1000 mm range and 11 kV output, the SE-DCA-110 keeps pace with high-speed film, converting and injection moulding cycles.
The two variants differ only in the air connection fitting. All other specifications are identical.
| Parameter | SE-DCA-110-xxxx-S | SE-DCA-110-xxxx-L |
|---|---|---|
| Air fitting | Straight — ⌀ 8 mm hose | L-type (90°) — ⌀ 8 mm hose |
| Fitting location | End of bar — hose exits parallel to bar axis | End of bar — hose exits at 90° to bar axis |
| Best for | Standard installations with direct hose routing | Space-constrained installations where a straight hose run is blocked |
| Pin | Function |
|---|---|
| 1 | +24 V DC |
| 2 | Not used |
| 3 | 24 V− (GND) |
| 4 | Fault output |
Use a 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable. Pin 2 is not used. Pin 4 provides a fault output signal for external fault indication. Do not connect or disconnect while power is applied.
| Applications | Description |
|---|---|
| Film & plastic winding / unwinding | Neutralise static on PE, PP and PET webs during winding and unwinding — where the bar must be positioned at a large air gap from the moving web. |
| Inside injection moulds | Position the bar adjacent to or inside the mould cavity to neutralise static on freshly moulded parts — preventing dust attraction immediately after moulding. |
| Conveyor systems — bottles, trays, parts | Eliminate static on bottles, trays, containers and moulded parts on conveyors — where the bar cannot be mounted close to the product. |
| Digital printing, converting & slitting lines | Control static on substrates at high line speeds — where the wide air gap makes passive ionization insufficient. |
| Robotic & automated handling systems | Mount on robotic arms or fixed frames in automated handling cells — delivering long-range ionization to parts at varying positions. |
| Operator tables — white goods & electronics | Provide wide-area ionization above assembly tables — covering large panels, housings or appliance components from a single overhead bar. |
| Material collection bins | Neutralise static inside bins and hoppers — preventing clumping, sticking and electrostatic adhesion to bin walls. |
Don't know the exact voltage, distance and speed on your line? Talk to our application engineers — we will calculate the antistatic configuration for your project within 1 working day.
| Parameter | Specification |
|---|---|
| Product code | SE-DCA-110-xxxx-S (straight fitting) · SE-DCA-110-xxxx-L (L-type fitting) — xxxx = length in mm |
| Power supply (sold separately) | SE-PSU-24-C-M12 (220 V AC to 24 V DC) |
| Ionization type | Pulsed DC — shockless |
| Pin current (safety) | < 250 μA |
| Ionization output voltage | 11 kV pulsed DC |
| Operating voltage | 24 V DC (21 – 28 V) · 0.5 A max. |
| Ionization range | 25 – 1000 mm * |
| Ordering length | 300 – 2000 mm in 100 mm steps |
| Air connection | ⌀ 8 mm hose — straight (-S) or L-type 90° (-L) fitting |
| Air pressure | Minimum 2 bar · dry, filtered |
| Air consumption | 205 l/min per 1000 mm length at 6 bar (scale proportionally by length) |
| Emitter pin material | Tungsten — extremely long lifetime |
| Polarity | Alternating pulsed DC — balanced ion output |
| Connector | M12 — use a 4-pin M12 cable (order separately) |
| Status indicator | Integrated LED — operational status |
| Operating temperature | 0 – 50 °C |
| Max. humidity | 70 % rH, non-condensing |
| Protection class | IP65 (with connector) |
| Housing | Industrial-grade, impact-resistant |
| Mounting | FG-AC-0005 T-fixings (M6 × 40 mm stud and flange nut; 2 per bar up to 1000 mm, +1 per additional 500 mm) · 180° adjustable mounting bracket |
| EMC compliance | 2014/30/EU — EMC Directive |
| Electrical safety | 2014/35/EU — Low Voltage Directive |
* Ionization range up to 1000 mm measured under standard conditions (20 °C, 50 % rH) with clean dry compressed air at rated pressure. Effective range may vary with ambient humidity, temperature, air pressure and line speed.
| Component | Description |
|---|---|
| SE-DCA-110 bar (variant + length) | Specify variant (-S or -L) and length in mm (300 – 2000). Example: SE-DCA-110-0600-S = 600 mm, straight fitting |
| SE-PSU-24-C-M12 power supply | 220 V AC to 24 V DC power supply, M12 version — required · sold separately |
| M12 cable | Industrial M12 connection cable — length to suit installation · sold separately |
| Compressed air supply | Dry, filtered compressed air · ⌀ 8 mm hose · minimum 2 bar at the bar · customer-supplied |
| Mounting brackets (optional) | Standard and custom brackets — contact FÖGE for options |
| Maintenance kit (optional) | FÖGE Antistatic Maintenance Kit — cleaning tools and spare tungsten emitter pins |
No. The bar operates from a standard 24 V DC supply (SE-PSU-24-C-M12, sold separately). The 11 kV ionization voltage is generated internally — no external HV transformer, HV cabling or HV safety zones are needed.
The primary function of the compressed air is to extend the ionization range. The air picks up the ions generated at the emitter pins and carries them across the working distance to the target surface — enabling effective static neutralisation at up to 1000 mm. Long-range static elimination is the design objective; the airflow is the means to achieve that reach, not a dust-removal system.
Only the air connection fitting: -S has a straight ⌀ 8 mm hose fitting; -L has an L-type (90°) ⌀ 8 mm fitting. All electrical and ionization specifications are identical. Choose -L when machine geometry prevents a straight hose connection.
The bar should span at least the full width of the material or zone to be neutralised. It is orderable in any length from 300 mm to 2000 mm. Specify the length and variant (-S or -L) when ordering.
Dry, filtered compressed air via a ⌀ 8 mm hose at a minimum of 2 bar. Air consumption is approximately 205 l/min per 1000 mm of bar length at 6 bar — scale proportionally for other lengths. Ensure the supply is free of moisture and oil.
Yes. The compact 24 V DC design, lightweight construction and absence of external HV components make it well suited for robotic arms and end effectors. Contact FÖGE for bracket options.
High-voltage equipment. Installation and maintenance by qualified personnel only, following the operating manual. Safety & compliance
SE-DCB-90Compact 9 kV pulsed DC static elimination — no HV transformer, 24 V DC supply, up to 200 mm range
SE-ACB-80Extended-range, high-speed static elimination for demanding industrial production lines