SE-ACB-55SE-ACB-55 Compact AC Antistatic Bar – 5.5 kV
High-speed, compact static elimination for industrial production lines
The FÖGE SE-ACB-80 is a high-power AC antistatic bar engineered for industrial production environments where standard 5.5 kV bars are no longer sufficient. Operating at 8 kV with an external SE-PAC-80 AC high-voltage power unit, it ionizes at distances of up to 250 mm — more than twice the range of the SE-ACB-55 — making it the right choice when installation geometry prevents close bar mounting, when materials carry exceptionally high static charges, or when line speeds push beyond 500 m/min.
Like the rest of the SE-ACB series, the SE-ACB-80 combines a washable, industrial-grade housing with shockless stainless steel emitter pins, a screened HFFR-protected cable and a plug-and-play HV connector for fast, tool-free installation. It is available in any length from 100 mm to 4500 mm, and the optional SE-CAB-AC-1 cable is available in 1 m steps within the 12 m total length per power unit.

The SE-ACB-80 is connected to an SE-PAC-80 high-voltage AC power unit, which supplies 8 kV to the bar's stainless steel emitter pins. The elevated voltage causes more intense ionization of the surrounding air, generating a denser cloud of balanced positive and negative ions compared to a 5.5 kV bar. This denser ion field is able to reach and neutralise static charges at distances up to 250 mm — and at the high charge densities typical of fast-moving heavy materials. The shockless circuit design limits pin current to below 50 μA at all times, ensuring full operator safety regardless of the higher operating voltage.
At 8 kV and 250 mm range, the SE-ACB-80 neutralises even the highest static charges found on heavy plastic sheet, board and wide-gap installations — where lower-power bars fail.
Effective at up to 700 m/min, it keeps pace with the fastest converting, printing and film processing lines without loss of ionization quality.
A 250 mm ionization range gives engineers freedom to mount the bar where machine geometry allows — no need to force the bar close to the material.
Eliminating static charge removes dust attraction and prevents coating, printing and lamination failures — improving yield and reducing rework.
Shockless design (< 50 μA pin current) and HFFR-protected cable ensure safe operation even when staff work in close proximity to the bar.
Connect up to 4 bars to one SE-PAC-80 power unit to cover wide machines without adding extra power supply units.
The optional SE-CAB-AC-1 cable, available in 1 m steps within the 12 m total length per power unit, gives flexibility when the power unit must be mounted away from the ionization point.
The SE-ACB-80 is the right choice when any of the following conditions apply. If none apply, the SE-ACB-55 is the more cost-effective option.
| Parameter | SE-ACB-55 (5.5 kV) | SE-ACB-80 (8 kV) |
|---|---|---|
| Ionization voltage | 5.5 kV | 8 kV |
| Ionization range | 25 – 100 mm | 25 – 250 mm |
| Max. line speed | 500 m/min | 700 m/min |
| Compatible power unit | SE-PAC-55 | SE-PAC-80 |
| Optional cable | Up to 12 m | 1 m steps, max. 12 m total |
| Best for | Standard production environments | High static charge, wide-gap, very high-speed lines |
| Applications | Description |
|---|---|
| Heavy plastic sheet & board | Neutralise intense static charges on thick plastic sheet, corrugated board and rigid packaging materials — where 5.5 kV bars cannot fully neutralise. |
| Wide-gap machine installations | Mount the bar at distances beyond 100 mm from the material surface without loss of ionization performance — ideal where machine geometry limits close mounting. |
| Very high-speed film lines | Neutralise static on plastic films moving at 500 – 700 m/min — the highest production speeds in converting and slitting. |
| Wide-web converting | Cover the full width of wide-format webs (film, paper, foil) running at high speed on winding, slitting and laminating machinery. |
| Printing on difficult substrates | Remove static from heavily charged substrates such as thick coated board, synthetic paper and metallised films before printing or coating. |
| Thermoforming & extrusion lines | Control static on hot extruded or thermoformed plastic sheet — where thermal conditions generate exceptionally high electrostatic charges. |
| Automotive interior plastics | Eliminate static on large-format plastic panels and trim components before paint or assembly — where a bar must span a wide area at distance. |
Don't know the exact voltage, distance and speed on your line? Talk to our application engineers — we will calculate the antistatic configuration for your project within 1 working day.
| Parameter | Specification |
|---|---|
| Product code | SE-ACB-80-xxxx (length in mm, e.g. SE-ACB-80-0300 = 300 mm) |
| Compatible power unit | SE-PAC-80-2-C (2 outputs) · SE-PAC-80-4-C (4 outputs) |
| Ionization type | High voltage AC — shockless |
| Ionization voltage | 8 kV |
| Ionization range | 25 – 250 mm * |
| Max. line speed | 700 m/min |
| Ordering length | 100 – 4500 mm |
| Pin current (safety) | < 50 μA (shockless — safe for operators) |
| Emitter pin material | Stainless steel (long service life) |
| Polarity | Alternating AC |
| Operating temperature | Max. 60 °C |
| Max. humidity | 70 % rH, non-condensing |
| Protection class | IP66 — fully sealed |
| Standard cable | C2 — 2 m HFFR-protected flex cable with HV connector |
| Optional cable | SE-CAB-AC-1 — non-standard cable lengths in 1 m steps, within the 12 m total length per power unit |
| Housing | Washable, rugged industrial-grade body |
| EMC compliance | 2014/30/EU — EMC Directive |
| Electrical safety | 2014/35/EU — Low Voltage Directive |
| Bars per power unit | Up to 4 bars per SE-PAC-80 power unit |
* Ionization range measured at standard conditions (20 °C, 50 % rH). Effective range may vary with ambient humidity, temperature and line speed.

| Component | Description |
|---|---|
| SE-ACB-80 antistatic bar | Main ionization bar — order in the required length (100 – 4500 mm) |
| SE-PAC-80-2-C power unit | 2-output AC high-voltage power unit — powers up to 2 SE-ACB-80 bars |
| SE-PAC-80-4-C power unit | 4-output AC high-voltage power unit — powers up to 4 SE-ACB-80 bars |
| Mounting brackets (optional) | Standard and custom brackets available — contact FÖGE for options |
| Extended cable (optional) | SE-CAB-AC-1: non-standard cable lengths in 1 m steps, within the 12 m total length per power unit |
| Maintenance kit | FÖGE Antistatic Maintenance Kit — cleaning tools and spare emitter pins |
The SE-ACB-80 operates at 8 kV versus 5.5 kV for the SE-ACB-55. This delivers a wider ionization range (up to 250 mm vs 100 mm), a higher maximum line speed (700 m/min vs 500 m/min), and the ability to neutralise more heavily charged materials. The SE-ACB-80 requires the SE-PAC-80 power unit; the SE-ACB-55 requires the SE-PAC-55. If your application works well within the SE-ACB-55 parameters, it is the more economical choice.
The SE-ACB-80 requires an SE-PAC-80 external AC high-voltage power unit. It is available in two configurations: SE-PAC-80-2-C (2 outputs, for up to 2 bars) and SE-PAC-80-4-C (4 outputs, for up to 4 bars). The power unit is not included with the bar and must be ordered separately.
No. The SE-ACB-80 requires the SE-PAC-80 power unit which delivers 8 kV. The SE-PAC-55 is rated for 5.5 kV and is only compatible with the SE-ACB-55 bar. Using mismatched units may result in reduced ionization performance or equipment damage.
The SE-ACB-80 is the preferred choice for heavily charged materials such as thick plastic sheet, rigid board, extruded plastics and metallised films — where the standard 5.5 kV bar cannot fully neutralise the charge. It is also ideal for any installation where the bar must be mounted more than 100 mm from the target surface.
Yes. The SE-ACB-80 is orderable in any length from 100 mm to 4500 mm. The bar should span at least the full width of the material to be neutralised. Contact FÖGE with your required length when placing an order.
Yes. The optional SE-CAB-AC-1 cable is available in non-standard lengths in 1 m steps. The total length of all bars and cables connected to one SE-PAC-80 power unit must not exceed 12 m.
High-voltage equipment. Installation and maintenance by qualified personnel only, following the operating manual. Safety & compliance
SE-ACB-55High-speed, compact static elimination for industrial production lines