SE-ACB-80 High Power AC Antistatic Bar – 8 kV

Extended-range, high-speed static elimination for demanding industrial production lines

Overview

The FÖGE SE-ACB-80 is a high-power AC antistatic bar engineered for industrial production environments where standard 5.5 kV bars are no longer sufficient. Operating at 8 kV with an external SE-PAC-80 AC high-voltage power unit, it ionizes at distances of up to 250 mm — more than twice the range of the SE-ACB-55 — making it the right choice when installation geometry prevents close bar mounting, when materials carry exceptionally high static charges, or when line speeds push beyond 500 m/min.

Like the rest of the SE-ACB series, the SE-ACB-80 combines a washable, industrial-grade housing with shockless stainless steel emitter pins, a screened HFFR-protected cable and a plug-and-play HV connector for fast, tool-free installation. It is available in any length from 100 mm to 4500 mm, and the optional SE-CAB-AC-1 cable is available in 1 m steps within the 12 m total length per power unit.

Key features

  • 8 kV AC ionization voltage — more than twice the power of standard 5.5 kV AC bars
  • Extended ionization range up to 250 mm — ideal where the bar cannot be positioned close to the material
  • Effective at line speeds up to 700 m/min — designed for the most demanding high-speed applications
  • Shockless operation — pin current < 50 μA, safe for operators at all times
  • Stainless steel emitter pins — long service life and corrosion resistance
  • Washable housing — easy to clean, suitable for dusty and humid environments
  • Screened HFFR-protected cable — flame-retardant and EMI-resistant
  • Plug-and-play HV connector — fast, tool-free installation and removal
  • Up to 4 bars connectable to a single SE-PAC-80 power unit
  • Orderable in any length from 100 mm to 4500 mm
  • Optional SE-CAB-AC-1 cable in 1 m steps (max. 12 m total length per power unit)

Request technical quoteDownload datasheet (PDF)

SE-ACB-80 AC antistatic bar with aluminium profile, yellow end caps, emitter pin row and HV cable

Industries

  • Plastics (heavy sheet, board, rigid packaging)
  • Printing & converting (high-speed, wide-web)
  • Thermoforming & extrusion
  • Flexible packaging (ultra-high-speed lines)
  • Automotive (large plastic components)
  • Paper & board (heavyweight substrates)
  • Textiles & technical fabrics

How it works

The SE-ACB-80 is connected to an SE-PAC-80 high-voltage AC power unit, which supplies 8 kV to the bar's stainless steel emitter pins. The elevated voltage causes more intense ionization of the surrounding air, generating a denser cloud of balanced positive and negative ions compared to a 5.5 kV bar. This denser ion field is able to reach and neutralise static charges at distances up to 250 mm — and at the high charge densities typical of fast-moving heavy materials. The shockless circuit design limits pin current to below 50 μA at all times, ensuring full operator safety regardless of the higher operating voltage.

Advantages & benefits

  1. Handles the most demanding processes

    At 8 kV and 250 mm range, the SE-ACB-80 neutralises even the highest static charges found on heavy plastic sheet, board and wide-gap installations — where lower-power bars fail.

  2. Speed performance

    Effective at up to 700 m/min, it keeps pace with the fastest converting, printing and film processing lines without loss of ionization quality.

  3. Flexible installation geometry

    A 250 mm ionization range gives engineers freedom to mount the bar where machine geometry allows — no need to force the bar close to the material.

  4. Fewer product defects

    Eliminating static charge removes dust attraction and prevents coating, printing and lamination failures — improving yield and reducing rework.

  5. Operator safety

    Shockless design (< 50 μA pin current) and HFFR-protected cable ensure safe operation even when staff work in close proximity to the bar.

  6. Scalable coverage

    Connect up to 4 bars to one SE-PAC-80 power unit to cover wide machines without adding extra power supply units.

  7. Extended cable reach

    The optional SE-CAB-AC-1 cable, available in 1 m steps within the 12 m total length per power unit, gives flexibility when the power unit must be mounted away from the ionization point.

When to choose the SE-ACB-80 over the SE-ACB-55

The SE-ACB-80 is the right choice when any of the following conditions apply. If none apply, the SE-ACB-55 is the more cost-effective option.

  • The bar cannot be mounted within 100 mm of the material surface due to machine geometry
  • The material carries an unusually high static charge (heavy plastic sheet, board, extruded materials)
  • Line speed exceeds 500 m/min
  • Standard 5.5 kV bars have been tried and are underperforming in your process
ParameterSE-ACB-55 (5.5 kV)SE-ACB-80 (8 kV)
Ionization voltage5.5 kV8 kV
Ionization range25 – 100 mm25 – 250 mm
Max. line speed500 m/min700 m/min
Compatible power unitSE-PAC-55SE-PAC-80
Optional cableUp to 12 m1 m steps, max. 12 m total
Best forStandard production environmentsHigh static charge, wide-gap, very high-speed lines

Applications

ApplicationsDescription
Heavy plastic sheet & boardNeutralise intense static charges on thick plastic sheet, corrugated board and rigid packaging materials — where 5.5 kV bars cannot fully neutralise.
Wide-gap machine installationsMount the bar at distances beyond 100 mm from the material surface without loss of ionization performance — ideal where machine geometry limits close mounting.
Very high-speed film linesNeutralise static on plastic films moving at 500 – 700 m/min — the highest production speeds in converting and slitting.
Wide-web convertingCover the full width of wide-format webs (film, paper, foil) running at high speed on winding, slitting and laminating machinery.
Printing on difficult substratesRemove static from heavily charged substrates such as thick coated board, synthetic paper and metallised films before printing or coating.
Thermoforming & extrusion linesControl static on hot extruded or thermoformed plastic sheet — where thermal conditions generate exceptionally high electrostatic charges.
Automotive interior plasticsEliminate static on large-format plastic panels and trim components before paint or assembly — where a bar must span a wide area at distance.

Not sure about voltage, distance or line speed?

Don't know the exact voltage, distance and speed on your line? Talk to our application engineers — we will calculate the antistatic configuration for your project within 1 working day.

Ask an application engineerDownload datasheet (PDF)

Technical specifications

SE-ACB-80 Technical specifications
ParameterSpecification
Product codeSE-ACB-80-xxxx (length in mm, e.g. SE-ACB-80-0300 = 300 mm)
Compatible power unitSE-PAC-80-2-C (2 outputs) · SE-PAC-80-4-C (4 outputs)
Ionization typeHigh voltage AC — shockless
Ionization voltage8 kV
Ionization range25 – 250 mm *
Max. line speed700 m/min
Ordering length100 – 4500 mm
Pin current (safety)< 50 μA (shockless — safe for operators)
Emitter pin materialStainless steel (long service life)
PolarityAlternating AC
Operating temperatureMax. 60 °C
Max. humidity70 % rH, non-condensing
Protection classIP66 — fully sealed
Standard cableC2 — 2 m HFFR-protected flex cable with HV connector
Optional cableSE-CAB-AC-1 — non-standard cable lengths in 1 m steps, within the 12 m total length per power unit
HousingWashable, rugged industrial-grade body
EMC compliance2014/30/EU — EMC Directive
Electrical safety2014/35/EU — Low Voltage Directive
Bars per power unitUp to 4 bars per SE-PAC-80 power unit

* Ionization range measured at standard conditions (20 °C, 50 % rH). Effective range may vary with ambient humidity, temperature and line speed.

dimensional drawing

Dimensional drawing of the SE-ACB-80 AC antistatic bar: profile 20.00 × 32.40 mm, overall length equals active length, 2 m HV cable
Dimensional drawing of the SE-ACB-80 AC antistatic bar: profile 20.00 × 32.40 mm, overall length equals active length, 2 m HV cable

Complete system — what you need

ComponentDescription
SE-ACB-80 antistatic barMain ionization bar — order in the required length (100 – 4500 mm)
SE-PAC-80-2-C power unit2-output AC high-voltage power unit — powers up to 2 SE-ACB-80 bars
SE-PAC-80-4-C power unit4-output AC high-voltage power unit — powers up to 4 SE-ACB-80 bars
Mounting brackets (optional)Standard and custom brackets available — contact FÖGE for options
Extended cable (optional)SE-CAB-AC-1: non-standard cable lengths in 1 m steps, within the 12 m total length per power unit
Maintenance kitFÖGE Antistatic Maintenance Kit — cleaning tools and spare emitter pins

Frequently asked questions

What is the difference between the SE-ACB-80 and SE-ACB-55?

The SE-ACB-80 operates at 8 kV versus 5.5 kV for the SE-ACB-55. This delivers a wider ionization range (up to 250 mm vs 100 mm), a higher maximum line speed (700 m/min vs 500 m/min), and the ability to neutralise more heavily charged materials. The SE-ACB-80 requires the SE-PAC-80 power unit; the SE-ACB-55 requires the SE-PAC-55. If your application works well within the SE-ACB-55 parameters, it is the more economical choice.

What power unit does the SE-ACB-80 require?

The SE-ACB-80 requires an SE-PAC-80 external AC high-voltage power unit. It is available in two configurations: SE-PAC-80-2-C (2 outputs, for up to 2 bars) and SE-PAC-80-4-C (4 outputs, for up to 4 bars). The power unit is not included with the bar and must be ordered separately.

Can I use an SE-PAC-55 power unit with the SE-ACB-80?

No. The SE-ACB-80 requires the SE-PAC-80 power unit which delivers 8 kV. The SE-PAC-55 is rated for 5.5 kV and is only compatible with the SE-ACB-55 bar. Using mismatched units may result in reduced ionization performance or equipment damage.

What materials is the SE-ACB-80 best suited for?

The SE-ACB-80 is the preferred choice for heavily charged materials such as thick plastic sheet, rigid board, extruded plastics and metallised films — where the standard 5.5 kV bar cannot fully neutralise the charge. It is also ideal for any installation where the bar must be mounted more than 100 mm from the target surface.

Can the bar length be customised?

Yes. The SE-ACB-80 is orderable in any length from 100 mm to 4500 mm. The bar should span at least the full width of the material to be neutralised. Contact FÖGE with your required length when placing an order.

Is a cable longer than 2 m available?

Yes. The optional SE-CAB-AC-1 cable is available in non-standard lengths in 1 m steps. The total length of all bars and cables connected to one SE-PAC-80 power unit must not exceed 12 m.

High-voltage equipment. Installation and maintenance by qualified personnel only, following the operating manual. Safety & compliance

Product catalogue