SE-CLEAN Antistatic Products Maintenance Kit

Cleaning fluid and nylon brush for FÖGE antistatic bars, blowers, airguns and nozzles

Overview

Antistatic devices must be cleaned regularly to keep their efficiency. The strong electric field attracts airborne dust and contaminants, the ionization of the air causes carbon to build up on the electrodes, and in textile applications ink or fibres can contaminate the pins. Dirty emitter pins reduce efficiency and can cause circuit overload and short circuits.

The FÖGE Antistatic Products Maintenance Kit contains a special cleaning fluid and a nylon brush. The fluid is non-conductive and water-free; it removes dust, carbon and dirt without damaging the product and evaporates without leaving any residue. The kit is designed for the maintenance of antistatic bars, air blowers, antistatic air guns and other antistatic devices.

Key features

  • Non-conductive, water-free cleaning fluid — evaporates without residue
  • Removes dust, carbon deposits, ink and fabric residue from emitter pins
  • Nylon brush, 225 × 35 × 22 mm — cleans gently without damaging the pins
  • Spray head for direct application
  • For FÖGE AC and DC bars, blowers, airguns and nozzles

Request technical quoteDownload datasheet (PDF)

SE-CLEAN antistatic products maintenance kit: white bottle of maintenance liquid with spray head and black nylon cleaning brush

Industries

  • Printing & converting
  • Textiles
  • Plastics & packaging
  • Woodworking & powder handling
  • Electronics & ESD-sensitive manufacturing
  • Automotive
  • Food & beverage
  • Pharmaceutical & medical

How it works

Switch the electrode off and do not switch it on again until it is dry. The cleaning fluid can be poured directly onto the electrode or applied with the spray head. The frequency of cleaning depends on the process and the environment.

Advantages & benefits

  1. Restored ionization efficiency

    Contaminated pins produce weaker, less stable ion output. Cleaning restores the ionization performance.

  2. Prevention of arcing and short circuits

    Dust and conductive particles on the pins can bridge pins and overload the ionization circuit.

  3. Longer equipment life

    Regular cleaning prolongs the working life of the device and avoids unplanned downtime.

Usage instructions

Switch the electrode OFF and do not switch it ON again until it is dry.

  1. Clean the static control device with the FÖGE cleaning brush.
  2. Attach the spray head to the bottle containing the cleaning fluid.
  3. Moisten a cloth with cleaning fluid and wipe the static control device, taking care around the emitters.
  4. Repeat brushing and cleaning until the static control device is clean.
  5. Polish the pins carefully with a dry cloth.

Cleaning frequency guide

ApplicationsDescription
Heavy dust — textile, woodworking, powder handlingWeekly or more often — inspect the pins every few days.
Printing and converting — ink, paper dust, adhesiveWeekly — after each production run if contamination is heavy.
Plastics and packaging — film, granulesEvery 2 weeks — watch the pins for contamination build-up.
General manufacturingMonthly — or whenever ionization performance visibly declines.
Electronics and cleanroom environmentsMonthly to quarterly.
After any production incidentImmediately — especially after an ink spill, a dust cloud or unusual static behaviour.

Not sure about voltage, distance or line speed?

Don't know the exact voltage, distance and speed on your line? Talk to our application engineers — we will calculate the antistatic configuration for your project within 1 working day.

Ask an application engineerDownload datasheet (PDF)

Technical specifications

SE-CLEAN Technical specifications
ParameterSpecification
Kit contentsAntistatic products maintenance liquid (bottle with spray head) + nylon cleaning brush
Cleaning fluidNon-conductive, water-free · solvent mixture, contains isoparaffins · free from halogenated and aromatic hydrocarbons · evaporates without residue · use undiluted
Brush dimensions225 × 35 × 22 mm
Brush filamentsNylon, ⌀ 0.35 mm, 20 mm depth
Compatible productsFÖGE AC and DC antistatic bars, air blowers, antistatic air guns and other antistatic devices
Personal protectionSafety glasses · protective gloves
Hazard statementsH304: May be fatal if swallowed and enters airways · H413: May cause long lasting harmful effects to aquatic life · EUH066: Repeated exposure may cause skin dryness or cracking
Precautionary statementsP273 · P301 + P310 · P331 · P405 · P501

Complete system — what you need

ComponentDescription
SE-CLEAN kitOne bottle of cleaning fluid with spray head and one nylon cleaning brush
Replacement fluid and brushesAvailable separately — contact FÖGE

Frequently asked questions

Do I need to rinse after cleaning?

No. The fluid evaporates without leaving any residue. Wipe the surface with a clean cloth and let it dry before switching the device on again.

Can I clean a bar while it is switched on?

No. Always switch the device off before cleaning and do not switch it on again until it is dry.

How do I know a bar needs cleaning?

Reduced ionization range, uneven neutralisation across the bar, visible dust or discolouration on the pins, or increasing static problems on the line.