SE-PACSE-PAC AC High Voltage Power Unit
5.5 kV or 8 kV AC power for up to 4 FÖGE antistatic bars and ionizers — compact, short-circuit protected, plug-and-play
The FÖGE SE-ACA is a long-range AC antistatic bar that combines high-voltage AC ionization with integrated compressed air delivery to reach an ionization range of up to 400 mm with the 8 kV SE-ACA-80 (up to 200 mm with the 5.5 kV SE-ACA-55) — compared with up to 250 mm for the passive SE-ACB-80. The bar generates ions at its stainless steel emitter pins in the same way as the SE-ACB-80, but a built-in air channel carries the ions outward to the target surface. This makes the SE-ACA the right choice where the bar must be mounted well away from the material, where 3D-shaped plastic parts need ions in recesses and cavities, or where the reach of an air-assisted system is needed without changing to pulsed DC technology.
The SE-ACA is built in two versions that differ only in the ionizing bar: the SE-ACA-55 (5.5 kV) runs on an SE-PAC-55 and the SE-ACA-80 (8 kV) on an SE-PAC-80 high-voltage AC power unit, each with a plug-and-play HV connector — up to 4 bars per power unit. The shockless design, stainless steel emitter pins, washable housing and screened HFFR-protected cable ensure reliable long-term operation. Compressed air is required at the installation point to reach the full ionization range.

The SE-ACA connects to an SE-PAC high-voltage AC power unit, which applies 5.5 kV (SE-ACA-55) or 8 kV (SE-ACA-80) AC to the bar's stainless steel emitter pins. The voltage ionizes the air around each pin and generates a balanced cloud of positive and negative ions — as in the SE-ACB-80. In addition, compressed air fed into the bar is directed over the ionization zone, picks up the ions and carries them at speed to the target surface. This air-assisted delivery extends the effective range to 400 mm with the SE-ACA-80 (250 mm for the passive SE-ACB-80) and directs the ions into three-dimensional shapes, cavities and recesses. The alternating AC polarity neutralises both charge polarities.
Extended reach for engineers who prefer AC ionization systems.
The air stream carries ions into recessed areas, mould cavities and inner surfaces of 3D parts.
Up to 400 mm working distance (SE-ACA-80) lets you mount the bar where the machine geometry allows.
Uses the same SE-PAC power units and HV connectors as the SE-ACB bars: SE-PAC-55 for the SE-ACA-55, SE-PAC-80 for the SE-ACA-80.
Shockless design (< 100 μA) and HFFR-protected cable.
| Parameter | SE-ACA-55 | SE-ACA-80 |
|---|---|---|
| Ionization voltage | 5.5 kV | 8 kV |
| Power unit | SE-PAC-55-2-C / SE-PAC-55-4-C | SE-PAC-80-2-C / SE-PAC-80-4-C |
| Ionization range (with compressed air) | Up to 200 mm | Up to 400 mm |
| Max. line speed | 300 m/min | 500 m/min |
| Ordering length | 100 – 2000 mm | 100 – 2000 mm |
| Everything else | Identical: air connection, cable, housing, environment, safety | Identical: air connection, cable, housing, environment, safety |
| Parameter | SE-ACA (this product) | SE-ACB-80 | SE-DCA-110 |
|---|---|---|---|
| Technology | AC + compressed air | AC passive | Pulsed DC + compressed air |
| Range | Up to 400 mm (SE-ACA-80) · 200 mm (SE-ACA-55) | Up to 250 mm | Up to 1000 mm |
| Power supply | SE-PAC-80 or SE-PAC-55 HV unit | SE-PAC-80 HV unit | 24 V DC (SE-PSU-24-C-M12) |
| Air required | Yes | No | Yes |
| 3D part reach | Yes — air carries ions in | Limited | Yes — air carries ions in |
| Applications | Description |
|---|---|
| 3D plastic parts & moulded components | Deliver ions into cavities, recesses and inner surfaces of moulded plastic parts. |
| Wide-gap machine installations | Mount the bar up to 400 mm (SE-ACA-80) or 200 mm (SE-ACA-55) from the material where machine geometry or guarding prevents close positioning. |
| Injection mould entry zones | Deliver ionized air into the mould area to neutralise parts as they are ejected. |
| High-speed film & web lines | Neutralise films, paper webs and foils at up to 500 m/min (SE-ACA-80) or 300 m/min (SE-ACA-55) at extended bar-to-material distances. |
| Automotive interior plastics | Eliminate static on large plastic panels and trim before paint or final assembly. |
| Wide-web converting | Cover the full width of wide webs from a fixed bar position. |
Don't know the exact voltage, distance and speed on your line? Talk to our application engineers — we will calculate the antistatic configuration for your project within 1 working day.
| Parameter | Specification |
|---|---|
| Product code | SE-ACA-55-xxxx (5.5 kV) · SE-ACA-80-xxxx (8 kV) — length in mm, e.g. SE-ACA-80-0600 = 600 mm |
| Compatible power unit | SE-ACA-55: SE-PAC-55-2-C / SE-PAC-55-4-C · SE-ACA-80: SE-PAC-80-2-C / SE-PAC-80-4-C |
| Ionization type | High voltage AC — shockless |
| Ionization voltage | 5.5 kV (SE-ACA-55) · 8 kV (SE-ACA-80) |
| Ionization range | Up to 200 mm (SE-ACA-55) · up to 400 mm (SE-ACA-80), with compressed air * |
| Max. line speed | 300 m/min (SE-ACA-55) · 500 m/min (SE-ACA-80) |
| Ordering length | 100 – 2000 mm in 100 mm steps |
| Air connection | 10 mm hose |
| Air pressure — dry filtered air | 2 bar (8 bar max.) |
| Pin current (safety) | < 100 μA — shockless (both versions) |
| Transformer current | Max. 5 mA (with fuse) |
| Emitter pin material | Stainless steel — long service life |
| Polarity | Alternating AC |
| Cable | C2: 2 m HFFR-protected cable with HV connector |
| Bars per power unit | Up to 2 or 4 per SE-PAC (2- or 4-output version), within 12 m total length of cables and bars |
| Environment | Max. 60 °C · 70 % rH non-condensing max. |
| Protection class | IP66 — fully sealed |
| Housing | Washable, industrial-grade |
| EMC compliance | 2014/30/EU — EMC Directive |
| Electrical safety | 2014/35/EU — Low Voltage Directive |
* Ionization range measured at standard conditions (20 °C, 50 % rH, with compressed air). Effective range may vary with air pressure, humidity, temperature and line speed.

| Component | Description |
|---|---|
| SE-ACA bar (specify length) | Long-range ionizing bar with integrated air channel |
| SE-PAC-55-2-C / -4-C or SE-PAC-80-2-C / -4-C | Required — 2 or 4 output AC power unit: 5.5 kV for the SE-ACA-55, 8 kV for the SE-ACA-80 |
| Compressed air supply | Dry, filtered air at 2 bar (8 bar max.) via 10 mm hose |
| SE-CAB-AC-1 extension cable (optional) | Non-standard cable lengths in 1 m steps within the 12 m total length per power unit |
Both are AC bars on the SE-PAC system. The SE-ACB-80 is a passive bar with a range of up to 250 mm; the SE-ACA adds an integrated air channel that carries the ions to 400 mm (SE-ACA-80) and into 3D cavities.
The SE-ACA uses AC technology and an SE-PAC power unit. The SE-DCA-110 uses pulsed DC from 24 V DC and reaches up to 1000 mm with compressed air.
Yes, with the 5.5 kV SE-ACA-55. The 8 kV SE-ACA-80 requires an SE-PAC-80.
It then works as a passive AC bar and does not reach the specified range. Without air, the SE-ACB bars are the recommended alternative.
Up to 2 on the 2-output and up to 4 on the 4-output SE-PAC, within the 12 m total length of cables and bars.
High-voltage equipment. Installation and maintenance by qualified personnel only, following the operating manual. Safety & compliance
SE-PAC5.5 kV or 8 kV AC power for up to 4 FÖGE antistatic bars and ionizers — compact, short-circuit protected, plug-and-play
SE-ACB-80Extended-range, high-speed static elimination for demanding industrial production lines
SE-DCA-110Long-range static elimination up to 1000 mm — compressed air-assisted ionization, 24 V DC, no HV transformer