SE-ACA Long Range AC Antistatic Bar with Air

Air-assisted 5.5 kV or 8 kV AC ionization up to 400 mm — for 3D parts, wide-gap installations and high-speed lines

Overview

The FÖGE SE-ACA is a long-range AC antistatic bar that combines high-voltage AC ionization with integrated compressed air delivery to reach an ionization range of up to 400 mm with the 8 kV SE-ACA-80 (up to 200 mm with the 5.5 kV SE-ACA-55) — compared with up to 250 mm for the passive SE-ACB-80. The bar generates ions at its stainless steel emitter pins in the same way as the SE-ACB-80, but a built-in air channel carries the ions outward to the target surface. This makes the SE-ACA the right choice where the bar must be mounted well away from the material, where 3D-shaped plastic parts need ions in recesses and cavities, or where the reach of an air-assisted system is needed without changing to pulsed DC technology.

The SE-ACA is built in two versions that differ only in the ionizing bar: the SE-ACA-55 (5.5 kV) runs on an SE-PAC-55 and the SE-ACA-80 (8 kV) on an SE-PAC-80 high-voltage AC power unit, each with a plug-and-play HV connector — up to 4 bars per power unit. The shockless design, stainless steel emitter pins, washable housing and screened HFFR-protected cable ensure reliable long-term operation. Compressed air is required at the installation point to reach the full ionization range.

Key features

  • Ionization range up to 400 mm (SE-ACA-80) or 200 mm (SE-ACA-55) with integrated compressed air
  • Two versions: 5.5 kV for the SE-PAC-55 or 8 kV for the SE-PAC-80
  • Effective at line speeds up to 500 m/min (SE-ACA-80) or 300 m/min (SE-ACA-55)
  • Integrated air channel carries ions to extended distances and into 3D cavities
  • Orderable from 100 mm to 2000 mm in 100 mm steps
  • Shockless design (< 100 μA)
  • Stainless steel emitter pins — long service life
  • Washable housing · IP66
  • Screened HFFR-protected cable with plug-and-play HV connector
  • Up to 4 bars per SE-PAC power unit

Request technical quoteDownload datasheet (PDF)

SE-ACA long range AC antistatic bar with air tube, push-in air fitting, mounting brackets, yellow end caps and HV cable

Industries

  • Plastics (3D parts, moulded components, thick sheet)
  • Automotive (panels, trim, interior assembly)
  • Printing & converting
  • Film & flexible packaging
  • Thermoforming & extrusion
  • Electronics
  • Paper & board

How it works

The SE-ACA connects to an SE-PAC high-voltage AC power unit, which applies 5.5 kV (SE-ACA-55) or 8 kV (SE-ACA-80) AC to the bar's stainless steel emitter pins. The voltage ionizes the air around each pin and generates a balanced cloud of positive and negative ions — as in the SE-ACB-80. In addition, compressed air fed into the bar is directed over the ionization zone, picks up the ions and carries them at speed to the target surface. This air-assisted delivery extends the effective range to 400 mm with the SE-ACA-80 (250 mm for the passive SE-ACB-80) and directs the ions into three-dimensional shapes, cavities and recesses. The alternating AC polarity neutralises both charge polarities.

Advantages & benefits

  1. Up to 400 mm range with AC technology

    Extended reach for engineers who prefer AC ionization systems.

  2. Reaches into 3D cavities and recesses

    The air stream carries ions into recessed areas, mould cavities and inner surfaces of 3D parts.

  3. Flexible mounting geometry

    Up to 400 mm working distance (SE-ACA-80) lets you mount the bar where the machine geometry allows.

  4. Stays within the SE-PAC system

    Uses the same SE-PAC power units and HV connectors as the SE-ACB bars: SE-PAC-55 for the SE-ACA-55, SE-PAC-80 for the SE-ACA-80.

  5. Operator safety

    Shockless design (< 100 μA) and HFFR-protected cable.

Versions

ParameterSE-ACA-55SE-ACA-80
Ionization voltage5.5 kV8 kV
Power unitSE-PAC-55-2-C / SE-PAC-55-4-CSE-PAC-80-2-C / SE-PAC-80-4-C
Ionization range (with compressed air)Up to 200 mmUp to 400 mm
Max. line speed300 m/min500 m/min
Ordering length100 – 2000 mm100 – 2000 mm
Everything elseIdentical: air connection, cable, housing, environment, safetyIdentical: air connection, cable, housing, environment, safety

Which product to choose — SE-ACA, SE-ACB-80 or SE-DCA-110

ParameterSE-ACA (this product)SE-ACB-80SE-DCA-110
TechnologyAC + compressed airAC passivePulsed DC + compressed air
RangeUp to 400 mm (SE-ACA-80) · 200 mm (SE-ACA-55)Up to 250 mmUp to 1000 mm
Power supplySE-PAC-80 or SE-PAC-55 HV unitSE-PAC-80 HV unit24 V DC (SE-PSU-24-C-M12)
Air requiredYesNoYes
3D part reachYes — air carries ions inLimitedYes — air carries ions in

Applications

ApplicationsDescription
3D plastic parts & moulded componentsDeliver ions into cavities, recesses and inner surfaces of moulded plastic parts.
Wide-gap machine installationsMount the bar up to 400 mm (SE-ACA-80) or 200 mm (SE-ACA-55) from the material where machine geometry or guarding prevents close positioning.
Injection mould entry zonesDeliver ionized air into the mould area to neutralise parts as they are ejected.
High-speed film & web linesNeutralise films, paper webs and foils at up to 500 m/min (SE-ACA-80) or 300 m/min (SE-ACA-55) at extended bar-to-material distances.
Automotive interior plasticsEliminate static on large plastic panels and trim before paint or final assembly.
Wide-web convertingCover the full width of wide webs from a fixed bar position.

Not sure about voltage, distance or line speed?

Don't know the exact voltage, distance and speed on your line? Talk to our application engineers — we will calculate the antistatic configuration for your project within 1 working day.

Ask an application engineerDownload datasheet (PDF)

Technical specifications

SE-ACA Technical specifications
ParameterSpecification
Product codeSE-ACA-55-xxxx (5.5 kV) · SE-ACA-80-xxxx (8 kV) — length in mm, e.g. SE-ACA-80-0600 = 600 mm
Compatible power unitSE-ACA-55: SE-PAC-55-2-C / SE-PAC-55-4-C · SE-ACA-80: SE-PAC-80-2-C / SE-PAC-80-4-C
Ionization typeHigh voltage AC — shockless
Ionization voltage5.5 kV (SE-ACA-55) · 8 kV (SE-ACA-80)
Ionization rangeUp to 200 mm (SE-ACA-55) · up to 400 mm (SE-ACA-80), with compressed air *
Max. line speed300 m/min (SE-ACA-55) · 500 m/min (SE-ACA-80)
Ordering length100 – 2000 mm in 100 mm steps
Air connection10 mm hose
Air pressure — dry filtered air2 bar (8 bar max.)
Pin current (safety)< 100 μA — shockless (both versions)
Transformer currentMax. 5 mA (with fuse)
Emitter pin materialStainless steel — long service life
PolarityAlternating AC
CableC2: 2 m HFFR-protected cable with HV connector
Bars per power unitUp to 2 or 4 per SE-PAC (2- or 4-output version), within 12 m total length of cables and bars
EnvironmentMax. 60 °C · 70 % rH non-condensing max.
Protection classIP66 — fully sealed
HousingWashable, industrial-grade
EMC compliance2014/30/EU — EMC Directive
Electrical safety2014/35/EU — Low Voltage Directive

* Ionization range measured at standard conditions (20 °C, 50 % rH, with compressed air). Effective range may vary with air pressure, humidity, temperature and line speed.

Dimensional drawings

Dimensional drawing of the SE-ACA: overall length equals active length, cross-section 80 × 55 mm, bar profile 34.4 mm, 2 m HV cable, ⌀ 10 mm compressed-air connection
Dimensional drawing of the SE-ACA: overall length equals active length, cross-section 80 × 55 mm, bar profile 34.4 mm, 2 m HV cable, ⌀ 10 mm compressed-air connection

Complete system — what you need

ComponentDescription
SE-ACA bar (specify length)Long-range ionizing bar with integrated air channel
SE-PAC-55-2-C / -4-C or SE-PAC-80-2-C / -4-CRequired — 2 or 4 output AC power unit: 5.5 kV for the SE-ACA-55, 8 kV for the SE-ACA-80
Compressed air supplyDry, filtered air at 2 bar (8 bar max.) via 10 mm hose
SE-CAB-AC-1 extension cable (optional)Non-standard cable lengths in 1 m steps within the 12 m total length per power unit

Frequently asked questions

What is the difference between the SE-ACA and the SE-ACB-80?

Both are AC bars on the SE-PAC system. The SE-ACB-80 is a passive bar with a range of up to 250 mm; the SE-ACA adds an integrated air channel that carries the ions to 400 mm (SE-ACA-80) and into 3D cavities.

What is the difference between the SE-ACA and the SE-DCA-110?

The SE-ACA uses AC technology and an SE-PAC power unit. The SE-DCA-110 uses pulsed DC from 24 V DC and reaches up to 1000 mm with compressed air.

Can I use an SE-PAC-55 with the SE-ACA?

Yes, with the 5.5 kV SE-ACA-55. The 8 kV SE-ACA-80 requires an SE-PAC-80.

Can the bar be used without compressed air?

It then works as a passive AC bar and does not reach the specified range. Without air, the SE-ACB bars are the recommended alternative.

How many SE-ACA bars can I connect to one SE-PAC power unit?

Up to 2 on the 2-output and up to 4 on the 4-output SE-PAC, within the 12 m total length of cables and bars.

High-voltage equipment. Installation and maintenance by qualified personnel only, following the operating manual. Safety & compliance