SE-BLC-F-75-CSE-BLC-F-75-C Compact Antistatic Blower – Pulsed DC
Maintenance-free pulsed DC ionizing blower — no compressed air, no high-voltage power unit, automatic pin cleaning
The FÖGE SE-BLL is a laminar flow pulsed DC ionizing blower designed for wide-area static elimination at workstations, production line positions and precision assembly areas — without compressed air or an external high-voltage power unit. Powered by 24 V DC via the SE-PSU-24-C-M12 power supply (sold separately), the SE-BLL drives a uniform laminar airflow along the full length of the unit and delivers ionized air to the target surface at distances up to 1000 mm. This reach makes it the right tool for covering wide workbenches, large plastic parts, screen and optical assemblies and ESD-sensitive electronics areas from a single overhead position.
The SE-BLL is available in five lengths from 530 to 2130 to match the width of the work area or machine. All variants share the same core design: tungsten emitter pins for a long service life; a replaceable ionizer module, so the ionization assembly can be exchanged at service without replacing the entire unit; and a replaceable 10 PPI foam filter that protects the fans and the ionizing system in dusty environments. An M12 5-pin industrial connector provides the power and signal connection.

The SE-BLL contains an integrated pulsed DC ionization unit that energises a row of tungsten emitter pins along the full length of the unit. The pulsed DC circuit alternates between positive and negative high-voltage pulses and generates a continuously balanced cloud of positive and negative ions. The built-in fans draw ambient air through the foam filter and push it through the unit in a laminar (smooth, parallel) flow — carrying the ions in a wide, even sheet of ionized air to the target surface. When the ionized air reaches a charged surface, ions of the opposite polarity neutralise the charge rapidly and evenly across the full width of the ionized air outlet. The fan speed is adjusted step by step with the front panel buttons to match the airflow to the working distance.
A single SE-BLL positioned overhead covers the full width of the work area — no need for multiple point ionizers or hand-held blowers across a wide bench.
At 1000 mm range the SE-BLL can be mounted well above the work surface — keeping the working area clear while still neutralising static effectively.
When the ionization assembly reaches end of life, only the module is replaced. Housing, fans and brackets stay in service.
No air lines to the workstation. The SE-BLL uses its own laminar fans — no compressed air noise and no pressure requirements at the bench.
Five lengths from 530 to 2130 mean there is an SE-BLL sized to the width of the work area — no overhang, no uncovered gaps.
The front panel buttons adjust the fan speed step by step — tune the airflow to the working distance and the sensitivity of the parts.
Cross-section: 119 mm wide, 123 mm housing height, 233.5 mm including bracket (see dimensional drawing).
| Product | Power consumption | Air flow speed at 1000 mm | Noise level at 1000 mm | Ionized air outlet A (mm) | B (mm) | Overall length C (mm) |
|---|---|---|---|---|---|---|
| SE-BLL-F-530-C | 18 W | 1.6 m/s | 38 dB | 541 | 53 | 684 |
| SE-BLL-F-700-C | 21 W | 2.1 m/s | 39 dB | 711 | 53 | 854 |
| SE-BLL-F-1055-C | 19 W | 3.1 m/s | 40 dB | 1066 | 53 | 1209 |
| SE-BLL-F-1420-C | 31 W | 2.1 m/s | 40 dB | 1431 | 53 | 1649 |
| SE-BLL-F-2130-C | 39 W | 3.1 m/s | 40 dB | 2141 | 53 | 2359 |
| Model | Typical coverage width | Best for |
|---|---|---|
| SE-BLL-F-530-C | Up to 500 mm | Single operator workstation, small PCB or component tray, narrow conveyor |
| SE-BLL-F-700-C | Up to 650 mm | Standard workbench position, medium electronics assembly area |
| SE-BLL-F-1055-C | Up to 1000 mm | Wide workbench, dual-operator station, medium conveyor or inspection line |
| SE-BLL-F-1420-C | Up to 1350 mm | Large machine installation, automotive trim or headlight inspection station |
| SE-BLL-F-2130-C | Up to 2000 mm | Extra-wide bench or machine, full-width coverage of large plastic or optical parts |
| Pin | Function |
|---|---|
| 1 | +24 V DC supply |
| 2 | Fault output |
| 3 | GND |
| 4 | Remote control |
Use a 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable.
| Applications | Description |
|---|---|
| ESD workbenches & electronics assembly | Continuous wide-area ionized airflow above PCB assembly benches, component handling areas and ESD-sensitive workstations. |
| Plastic components & finishing lines | Neutralise static on injection-moulded plastic parts, covers and housings before painting, coating or assembly — preventing dust from bonding to freshly moulded surfaces. |
| Optical parts & screen assembly | Gentle, uniform ionized airflow across lenses, screens, sensor modules and optical components — where high-velocity compressed air is too aggressive and point ionizers leave uncovered areas. |
| Automotive lighting & interior trim | Eliminate static on headlight assemblies, reflectors and interior plastic panels before assembly or quality inspection — covering the full width of wide parts from one overhead position. |
| Cleanroom & controlled-environment workstations | Quiet operation in cleanroom-adjacent and controlled production environments — where low noise, filtered airflow and low maintenance are required. |
| Quality control & pre-coating inspection | Make sure parts are static-free across their full width before coating, labelling, packaging or final inspection. |
Don't know the exact voltage, distance and speed on your line? Talk to our application engineers — we will calculate the antistatic configuration for your project within 1 working day.
| Parameter | Specification |
|---|---|
| Product code | SE-BLL-F-xxxx-C (530 / 700 / 1055 / 1420 / 2130) |
| Power supply (sold separately) | SE-PSU-24-C-M12 (220 V AC to 24 V DC) |
| Operating voltage | 24 V DC (21 – 28 V) |
| Ionization type | Pulsed DC — shockless |
| Pin current (safety) | < 250 μA |
| Ionization range | Up to 1000 mm |
| Ionization performance | 1 kV → 100 V in < 7 s at 1000 mm distance |
| Fan speed adjustment | Front panel buttons (▲ / ▼) — step-adjustable |
| Emitter pin material | Tungsten — extremely long lifetime |
| Pin cleaning | Manual — remove the front cover and clean the tungsten pins with the brush of the FÖGE maintenance kit |
| Ionizer module | Replaceable — the full unit does not need to be replaced at service |
| Filter | Replaceable foam filter, 10 PPI |
| Polarity | Alternating pulsed DC — balanced ion output |
| Connector | M12, 5-pin (cable not included) |
| LED indicators | 24 V supply · ionization status (green: OK, red: fault) · fan speed level |
| Controls | Power button · fan speed buttons ▲ / ▼ |
| Ground terminal | Yes — do not operate without connecting the ground terminal to earth |
| Mounting | Adjustable 2-way mounting bracket — bottom or rear mounting · 4 × ⌀ 9 mm holes |
| Operating temperature | 0 – 50 °C |
| Max. humidity | 70 % rH |
| Housing | Industrial-grade, impact-resistant |
| EMC compliance | 2014/30/EU — EMC Directive |
| Electrical safety | 2014/35/EU — Low Voltage Directive |
Ionization range measured under standard conditions (20 °C, 50 % rH) with fans at maximum speed. Effective range may vary with ambient temperature, humidity and fan speed setting. Air flow speed and noise level are measured at 1000 mm.

| Component | Description |
|---|---|
| SE-BLL blower (select length) | SE-BLL-F-530-C / -700-C / -1055-C / -1420-C / -2130-C |
| SE-PSU-24-C-M12 power supply | 220 V AC to 24 V DC adapter — required · sold separately |
| 4-pin M12 cable | Industrial M12 connection cable — length to suit installation · sold separately |
| Foam filter (optional) | Replaceable 10 PPI foam filter — orderable as accessory |
| Replacement ionizer module | Spare ionizer assembly — contact FÖGE for the part code |
| Maintenance kit (optional) | FÖGE Antistatic Maintenance Kit — cleaning fluid and brush |
No. The SE-BLL operates at 24 V DC and contains its own pulsed DC ionization circuit. The SE-PSU-24-C-M12 power supply (220 V AC to 24 V DC) is required and sold separately.
Up to 1000 mm. The SE-BLL neutralises a surface from 1 kV down to 100 V in less than 7 seconds at 1000 mm distance — twice the 500 mm range of the SE-BLC-F-75-C compact blower.
The ionizer module is the assembly that contains the high-voltage ionization circuit and the emitter pins. When it reaches end of life, only the module is exchanged — housing, fans and mounting bracket stay in service. Contact FÖGE for the replacement module part code.
The ionized air outlet should span at least the full width of the work area or material to be neutralised. If the required width falls between two lengths, select the next length up.
With the ▲ / ▼ buttons on the front control panel. Higher fan speed is recommended for longer working distances, lower fan speed for close-range or delicate applications.
No. The SE-BLL uses its own built-in fans. Only a 24 V DC connection via the SE-PSU-24-C-M12 adapter is needed.
A 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable.
The SE-BLL suits cleanroom-adjacent and controlled-environment workstations thanks to its quiet operation, foam filter and laminar airflow. For certified cleanroom classifications, contact FÖGE to confirm suitability.
Remove the front cover and clean the tungsten pins with the brush from the FÖGE Antistatic Products Maintenance Kit, then refit the cover. Clean the foam filters with a brush, compressed air or water.
High-voltage equipment. Installation and maintenance by qualified personnel only, following the operating manual. Safety & compliance
SE-BLC-F-75-CMaintenance-free pulsed DC ionizing blower — no compressed air, no high-voltage power unit, automatic pin cleaning
SE-BLA220 V AC mains-powered long-range ionizing blower — up to approx. 1 metre range, potentiometer fan control, for conveyors, assembly stations and 3D objects
SE-SFM-030Handheld non-contact surface charge measurement up to 200 kV — two auto-selected ranges, polarity display, hold function