Stretch blow moulding — preform loading with SE-DCB-110
In blow moulding the heated preforms are moved into the mould. High static charge makes them move, swing or misalign during the transfer. If a preform is not perfectly aligned when the heavy mould halves close, the bottle is crushed — or the mould closes onto solid plastic and damages the mould faces and core pins. An SE-DCB-110 at the preform loading station neutralises the preforms immediately before they enter the mould, so they hang straight and the mould closes safely.

The problem
In blow molding—frequently used in the plastics industry to produce bottles and containers—the "parison" or "preform" (the raw plastic material) is heated and moved into the mold. High static charges cause these preforms to move, swing, or misalign as they are transferred. If the raw material is not perfectly aligned when the heavy metal mold halves close, it results in a "crushed" or defective product. Worse, this misalignment can cause the mold to close onto the solid plastic, leading to catastrophic physical damage to the expensive mold faces and core pins.
The solution
Targeted ionizing air nozzles or specialized ionizing bars are installed at the preform loading station. By neutralizing the static charge on the raw material immediately before it enters the mold, the electrostatic forces that cause movement are eliminated. This ensures the preforms stay perfectly oriented and stationary as the mold closes, preventing product defects and protecting the machinery from collision damage.
Application
Ensuring precise alignment and mold protection during the high-speed production of plastic bottles, containers, and chemical carboys.
1 · SE-DCB-110 — preform loading station
Beside the hanging preforms just before the mould, about 120 mm away; the pins point at the preforms.
- Ionization
- 11 kV pulsed DC · shockless
- Ionization range
- 100 – 600 mm
- Ordering length
- 300 – 4500 mm (100 mm steps)
- Supply
- 24 V DC · SE-PSU-24-C-M12
Also suitable for preform loading
Other FÖGE ionizer for this station.
Schematic model, not to scale. Machines and parts are generic — no specific manufacturer or brand.