# FÖGE Antistatic — full product data Publisher: FÖGE Elektronik GmbH, Presentstr. 3, 63939 Wörth am Main, Germany. Contact: +49 9372 9809477, contact form https://foge-antistatic.com/contact/. ## SE-ACB-55 Compact AC Antistatic Bar – 5.5 kV URL: https://foge-antistatic.com/products/static-electricity/static-elimination/se-acb-55/ Category: Static elimination · Family: AC antistatic bars High-speed, compact static elimination for industrial production lines. The FÖGE SE-ACB-55 is a compact, economical AC antistatic bar purpose-built for high-speed industrial production lines that require reliable static charge neutralisation in confined installation spaces. Operating at 5.5 kV in combination with an external SE-PAC AC high-voltage power unit, it generates a continuous field of positive and negative ions that neutralise static electricity on materials such as plastic film, paper, foil and textiles. Its robust, washable housing and shockless stainless steel emitter pins make it a dependable long-term solution for continuous operation in demanding factory environments. The plug-and-play HV connector allows fast installation and replacement without tools, and the screened HFFR-protected cable ensures both flame safety and EMI resistance. ### Key features - Compact OEM bar design — fits into space-constrained machine layouts - 5.5 kV AC ionization voltage — reliable static elimination across standard production environments - Ionization range up to 100 mm - Effective at line speeds up to 500 m/min - Shockless operation — pin current < 50 μA, safe for operators - Stainless steel emitter pins — long service life and corrosion resistance - Washable housing — easy to clean, suitable for dusty and humid environments - Screened HFFR-protected cable — flame-retardant, EMI-resistant - Plug-and-play HV connector — fast, tool-free installation and removal - Up to 4 bars connectable to a single SE-PAC power unit - Orderable in any length from 100 mm to 4500 mm - Optional cable lengths from 1 m up to 12 m (SE-CAB-AC-1) ### How it works The SE-ACB-55 is connected to an SE-PAC-55 high-voltage AC power unit, which supplies 5.5 kV to the bar's stainless steel emitter pins. The alternating high-voltage signal causes the air surrounding the pins to ionize, creating a balanced mixture of positive and negative ions. As charged material passes within 25 – 100 mm of the bar, these ions are attracted to the oppositely charged surface and neutralise the static charge — reducing it to a safe, near-zero level. The shockless circuit design limits pin current to below 50 μA at all times, ensuring operator safety without affecting ionization performance. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-ACB-55-xxxx (length in mm added to code, e.g. SE-ACB-55-0300) | | Compatible power unit | SE-PAC-55-2-C (2 outputs) · SE-PAC-55-4-C (4 outputs) | | Ionization type | High voltage AC — shockless | | Ionization voltage | 5.5 kV | | Ionization range | 25 – 100 mm * | | Max. line speed | 500 m/min | | Ordering length | 100 – 4500 mm | | Pin current (safety) | < 50 μA (shockless — safe for operators) | | Emitter pin material | Stainless steel (long service life) | | Polarity | Alternating AC | | Operating temperature | Max. 60 °C | | Max. humidity | 70 % rH, non-condensing | | Protection class | IP66 — fully sealed | | Standard cable | C2 — 2 m HFFR-protected flex cable with HV connector | | Optional cable | SE-CAB-AC-1 — non-standard cable 1 m, orderable up to 12 m | | Housing | Washable, rugged industrial-grade body | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | | Bars per power unit | Up to 4 bars per SE-PAC power unit | * Ionization range measured at standard conditions (20 °C, 50 % rH). Effective range may vary with ambient humidity, temperature and line speed. ### Applications - Plastic film & sheet production: Neutralise static during winding, unwinding and slitting of PE, PP, PET and other plastic films — preventing dust attraction and film sticking. - Flexible packaging: Prevent film misalignment, sticking and sealing defects on VFFS and HFFS packaging machines. - Paper & board processing: Eliminate sheet curl, jamming and charge build-up in printing, laminating and converting lines. - Labelling machines: Improve label placement accuracy and prevent label-to-label sticking at high production speeds. - Printing (flexo, offset): Remove static from substrates before printing to prevent ink smearing, spreading and dot gain. - Textile lines: Control static during weaving, cutting, slitting and printing of synthetic and natural fibre fabrics. - Converting machinery: Ensure clean cuts, accurate winding and consistent tension control on slitting and rewinding equipment. Industries: Plastics & flexible packaging; Printing & converting; Textiles & nonwovens; Food & beverage packaging; Pharmaceuticals & medical devices; Labels & adhesive tapes. ### Complete system - SE-ACB-55 antistatic bar: Main ionization bar — order in the required length (100 – 4500 mm) - SE-PAC-55-2-C power unit: 2-output AC high-voltage power unit — powers up to 2 SE-ACB-55 bars - SE-PAC-55-4-C power unit: 4-output AC high-voltage power unit — powers up to 4 SE-ACB-55 bars - Mounting brackets (optional): Standard and custom brackets available — contact FÖGE for options - Extended cable (optional): SE-CAB-AC-1: non-standard cable from 1 m to 12 m for flexible installation - Maintenance kit: FÖGE Antistatic Maintenance Kit — cleaning tools and spare emitter pins ### FAQ Q: What power unit does the SE-ACB-55 require? A: The SE-ACB-55 requires an SE-PAC-55 external AC high-voltage power unit. It is available in two configurations: SE-PAC-55-2-C (2 outputs, for up to 2 bars) and SE-PAC-55-4-C (4 outputs, for up to 4 bars). The power unit is not included with the bar and must be ordered separately. Q: What is the maximum ionization distance? A: The SE-ACB-55 effectively neutralises static charges at distances of 25 to 100 mm from the bar surface. Effective range may vary depending on ambient temperature, humidity and line speed. For applications requiring distances beyond 100 mm, the SE-ACB-80 (8 kV) is recommended. Q: What materials can the SE-ACB-55 neutralise? A: The bar is effective on all non-conductive materials that accumulate static charge — including PE, PP, PET and BOPP plastic films, paper, board, textiles, rubber and composites. It is not designed for use with conductive or metal materials. Q: Can the bar length be customised? A: Yes. The SE-ACB-55 is orderable in any length from 100 mm to 4500 mm. The bar length should span at least the full width of the material to be neutralised. Contact FÖGE with your required length when placing an order. Q: Can I use a longer cable than the standard 2 m? A: Yes. The optional SE-CAB-AC-1 cable allows non-standard lengths from 1 m up to 12 m, providing flexibility for installations where the power unit is mounted further from the bar. Q: Is the bar washable? A: Yes. The housing is fully washable. Regular cleaning of the emitter pins is recommended to maintain ionization efficiency. The FÖGE Antistatic Maintenance Kit contains all tools and materials needed for routine service. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-acb-55-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-acb-55-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-acb-55-dimensional-drawing-en.pdf ### 3D applications - Side seal bag making with SE-ACB-55: https://foge-antistatic.com/applications/side-seal-bag-making-se-acb-55/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-side-seal-bag-making-se-acb-55-application-sheet-en.pdf) ## SE-ACB-80 High Power AC Antistatic Bar – 8 kV URL: https://foge-antistatic.com/products/static-electricity/static-elimination/se-acb-80/ Category: Static elimination · Family: AC antistatic bars Extended-range, high-speed static elimination for demanding industrial production lines. The FÖGE SE-ACB-80 is a high-power AC antistatic bar engineered for industrial production environments where standard 5.5 kV bars are no longer sufficient. Operating at 8 kV with an external SE-PAC-80 AC high-voltage power unit, it ionizes at distances of up to 250 mm — more than twice the range of the SE-ACB-55 — making it the right choice when installation geometry prevents close bar mounting, when materials carry exceptionally high static charges, or when line speeds push beyond 500 m/min. Like the rest of the SE-ACB series, the SE-ACB-80 combines a washable, industrial-grade housing with shockless stainless steel emitter pins, a screened HFFR-protected cable and a plug-and-play HV connector for fast, tool-free installation. It is available in any length from 100 mm to 4500 mm, and the optional SE-CAB-AC-1 cable is available in 1 m steps within the 12 m total length per power unit. ### Key features - 8 kV AC ionization voltage — more than twice the power of standard 5.5 kV AC bars - Extended ionization range up to 250 mm — ideal where the bar cannot be positioned close to the material - Effective at line speeds up to 700 m/min — designed for the most demanding high-speed applications - Shockless operation — pin current < 50 μA, safe for operators at all times - Stainless steel emitter pins — long service life and corrosion resistance - Washable housing — easy to clean, suitable for dusty and humid environments - Screened HFFR-protected cable — flame-retardant and EMI-resistant - Plug-and-play HV connector — fast, tool-free installation and removal - Up to 4 bars connectable to a single SE-PAC-80 power unit - Orderable in any length from 100 mm to 4500 mm - Optional SE-CAB-AC-1 cable in 1 m steps (max. 12 m total length per power unit) ### How it works The SE-ACB-80 is connected to an SE-PAC-80 high-voltage AC power unit, which supplies 8 kV to the bar's stainless steel emitter pins. The elevated voltage causes more intense ionization of the surrounding air, generating a denser cloud of balanced positive and negative ions compared to a 5.5 kV bar. This denser ion field is able to reach and neutralise static charges at distances up to 250 mm — and at the high charge densities typical of fast-moving heavy materials. The shockless circuit design limits pin current to below 50 μA at all times, ensuring full operator safety regardless of the higher operating voltage. ### When to choose the SE-ACB-80 over the SE-ACB-55 The SE-ACB-80 is the right choice when any of the following conditions apply. If none apply, the SE-ACB-55 is the more cost-effective option. - The bar cannot be mounted within 100 mm of the material surface due to machine geometry - The material carries an unusually high static charge (heavy plastic sheet, board, extruded materials) - Line speed exceeds 500 m/min - Standard 5.5 kV bars have been tried and are underperforming in your process | Parameter | SE-ACB-55 (5.5 kV) | SE-ACB-80 (8 kV) | |---|---|---| | Ionization voltage | 5.5 kV | 8 kV | | Ionization range | 25 – 100 mm | 25 – 250 mm | | Max. line speed | 500 m/min | 700 m/min | | Compatible power unit | SE-PAC-55 | SE-PAC-80 | | Optional cable | Up to 12 m | 1 m steps, max. 12 m total | | Best for | Standard production environments | High static charge, wide-gap, very high-speed lines | ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-ACB-80-xxxx (length in mm, e.g. SE-ACB-80-0300 = 300 mm) | | Compatible power unit | SE-PAC-80-2-C (2 outputs) · SE-PAC-80-4-C (4 outputs) | | Ionization type | High voltage AC — shockless | | Ionization voltage | 8 kV | | Ionization range | 25 – 250 mm * | | Max. line speed | 700 m/min | | Ordering length | 100 – 4500 mm | | Pin current (safety) | < 50 μA (shockless — safe for operators) | | Emitter pin material | Stainless steel (long service life) | | Polarity | Alternating AC | | Operating temperature | Max. 60 °C | | Max. humidity | 70 % rH, non-condensing | | Protection class | IP66 — fully sealed | | Standard cable | C2 — 2 m HFFR-protected flex cable with HV connector | | Optional cable | SE-CAB-AC-1 — non-standard cable lengths in 1 m steps, within the 12 m total length per power unit | | Housing | Washable, rugged industrial-grade body | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | | Bars per power unit | Up to 4 bars per SE-PAC-80 power unit | * Ionization range measured at standard conditions (20 °C, 50 % rH). Effective range may vary with ambient humidity, temperature and line speed. ### Applications - Heavy plastic sheet & board: Neutralise intense static charges on thick plastic sheet, corrugated board and rigid packaging materials — where 5.5 kV bars cannot fully neutralise. - Wide-gap machine installations: Mount the bar at distances beyond 100 mm from the material surface without loss of ionization performance — ideal where machine geometry limits close mounting. - Very high-speed film lines: Neutralise static on plastic films moving at 500 – 700 m/min — the highest production speeds in converting and slitting. - Wide-web converting: Cover the full width of wide-format webs (film, paper, foil) running at high speed on winding, slitting and laminating machinery. - Printing on difficult substrates: Remove static from heavily charged substrates such as thick coated board, synthetic paper and metallised films before printing or coating. - Thermoforming & extrusion lines: Control static on hot extruded or thermoformed plastic sheet — where thermal conditions generate exceptionally high electrostatic charges. - Automotive interior plastics: Eliminate static on large-format plastic panels and trim components before paint or assembly — where a bar must span a wide area at distance. Industries: Plastics (heavy sheet, board, rigid packaging); Printing & converting (high-speed, wide-web); Thermoforming & extrusion; Flexible packaging (ultra-high-speed lines); Automotive (large plastic components); Paper & board (heavyweight substrates); Textiles & technical fabrics. ### Complete system - SE-ACB-80 antistatic bar: Main ionization bar — order in the required length (100 – 4500 mm) - SE-PAC-80-2-C power unit: 2-output AC high-voltage power unit — powers up to 2 SE-ACB-80 bars - SE-PAC-80-4-C power unit: 4-output AC high-voltage power unit — powers up to 4 SE-ACB-80 bars - Mounting brackets (optional): Standard and custom brackets available — contact FÖGE for options - Extended cable (optional): SE-CAB-AC-1: non-standard cable lengths in 1 m steps, within the 12 m total length per power unit - Maintenance kit: FÖGE Antistatic Maintenance Kit — cleaning tools and spare emitter pins ### FAQ Q: What is the difference between the SE-ACB-80 and SE-ACB-55? A: The SE-ACB-80 operates at 8 kV versus 5.5 kV for the SE-ACB-55. This delivers a wider ionization range (up to 250 mm vs 100 mm), a higher maximum line speed (700 m/min vs 500 m/min), and the ability to neutralise more heavily charged materials. The SE-ACB-80 requires the SE-PAC-80 power unit; the SE-ACB-55 requires the SE-PAC-55. If your application works well within the SE-ACB-55 parameters, it is the more economical choice. Q: What power unit does the SE-ACB-80 require? A: The SE-ACB-80 requires an SE-PAC-80 external AC high-voltage power unit. It is available in two configurations: SE-PAC-80-2-C (2 outputs, for up to 2 bars) and SE-PAC-80-4-C (4 outputs, for up to 4 bars). The power unit is not included with the bar and must be ordered separately. Q: Can I use an SE-PAC-55 power unit with the SE-ACB-80? A: No. The SE-ACB-80 requires the SE-PAC-80 power unit which delivers 8 kV. The SE-PAC-55 is rated for 5.5 kV and is only compatible with the SE-ACB-55 bar. Using mismatched units may result in reduced ionization performance or equipment damage. Q: What materials is the SE-ACB-80 best suited for? A: The SE-ACB-80 is the preferred choice for heavily charged materials such as thick plastic sheet, rigid board, extruded plastics and metallised films — where the standard 5.5 kV bar cannot fully neutralise the charge. It is also ideal for any installation where the bar must be mounted more than 100 mm from the target surface. Q: Can the bar length be customised? A: Yes. The SE-ACB-80 is orderable in any length from 100 mm to 4500 mm. The bar should span at least the full width of the material to be neutralised. Contact FÖGE with your required length when placing an order. Q: Is a cable longer than 2 m available? A: Yes. The optional SE-CAB-AC-1 cable is available in non-standard lengths in 1 m steps. The total length of all bars and cables connected to one SE-PAC-80 power unit must not exceed 12 m. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-acb-80-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-acb-80-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-acb-80-dimensional-drawing-en.pdf ## SE-ACA Long Range AC Antistatic Bar with Air URL: https://foge-antistatic.com/products/static-electricity/static-elimination/se-aca/ Category: Static elimination · Family: AC antistatic bars Air-assisted 5.5 kV or 8 kV AC ionization up to 400 mm — for 3D parts, wide-gap installations and high-speed lines. The FÖGE SE-ACA is a long-range AC antistatic bar that combines high-voltage AC ionization with integrated compressed air delivery to reach an ionization range of up to 400 mm with the 8 kV SE-ACA-80 (up to 200 mm with the 5.5 kV SE-ACA-55) — compared with up to 250 mm for the passive SE-ACB-80. The bar generates ions at its stainless steel emitter pins in the same way as the SE-ACB-80, but a built-in air channel carries the ions outward to the target surface. This makes the SE-ACA the right choice where the bar must be mounted well away from the material, where 3D-shaped plastic parts need ions in recesses and cavities, or where the reach of an air-assisted system is needed without changing to pulsed DC technology. The SE-ACA is built in two versions that differ only in the ionizing bar: the SE-ACA-55 (5.5 kV) runs on an SE-PAC-55 and the SE-ACA-80 (8 kV) on an SE-PAC-80 high-voltage AC power unit, each with a plug-and-play HV connector — up to 4 bars per power unit. The shockless design, stainless steel emitter pins, washable housing and screened HFFR-protected cable ensure reliable long-term operation. Compressed air is required at the installation point to reach the full ionization range. ### Key features - Ionization range up to 400 mm (SE-ACA-80) or 200 mm (SE-ACA-55) with integrated compressed air - Two versions: 5.5 kV for the SE-PAC-55 or 8 kV for the SE-PAC-80 - Effective at line speeds up to 500 m/min (SE-ACA-80) or 300 m/min (SE-ACA-55) - Integrated air channel carries ions to extended distances and into 3D cavities - Orderable from 100 mm to 2000 mm in 100 mm steps - Shockless design (< 100 μA) - Stainless steel emitter pins — long service life - Washable housing · IP66 - Screened HFFR-protected cable with plug-and-play HV connector - Up to 4 bars per SE-PAC power unit ### How it works The SE-ACA connects to an SE-PAC high-voltage AC power unit, which applies 5.5 kV (SE-ACA-55) or 8 kV (SE-ACA-80) AC to the bar's stainless steel emitter pins. The voltage ionizes the air around each pin and generates a balanced cloud of positive and negative ions — as in the SE-ACB-80. In addition, compressed air fed into the bar is directed over the ionization zone, picks up the ions and carries them at speed to the target surface. This air-assisted delivery extends the effective range to 400 mm with the SE-ACA-80 (250 mm for the passive SE-ACB-80) and directs the ions into three-dimensional shapes, cavities and recesses. The alternating AC polarity neutralises both charge polarities. ### Versions | Parameter | SE-ACA-55 | SE-ACA-80 | |---|---|---| | Ionization voltage | 5.5 kV | 8 kV | | Power unit | SE-PAC-55-2-C / SE-PAC-55-4-C | SE-PAC-80-2-C / SE-PAC-80-4-C | | Ionization range (with compressed air) | Up to 200 mm | Up to 400 mm | | Max. line speed | 300 m/min | 500 m/min | | Ordering length | 100 – 2000 mm | 100 – 2000 mm | | Everything else | Identical: air connection, cable, housing, environment, safety | Identical: air connection, cable, housing, environment, safety | ### Which product to choose — SE-ACA, SE-ACB-80 or SE-DCA-110 | Parameter | SE-ACA (this product) | SE-ACB-80 | SE-DCA-110 | |---|---|---|---| | Technology | AC + compressed air | AC passive | Pulsed DC + compressed air | | Range | Up to 400 mm (SE-ACA-80) · 200 mm (SE-ACA-55) | Up to 250 mm | Up to 1000 mm | | Power supply | SE-PAC-80 or SE-PAC-55 HV unit | SE-PAC-80 HV unit | 24 V DC (SE-PSU-24-C-M12) | | Air required | Yes | No | Yes | | 3D part reach | Yes — air carries ions in | Limited | Yes — air carries ions in | ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-ACA-55-xxxx (5.5 kV) · SE-ACA-80-xxxx (8 kV) — length in mm, e.g. SE-ACA-80-0600 = 600 mm | | Compatible power unit | SE-ACA-55: SE-PAC-55-2-C / SE-PAC-55-4-C · SE-ACA-80: SE-PAC-80-2-C / SE-PAC-80-4-C | | Ionization type | High voltage AC — shockless | | Ionization voltage | 5.5 kV (SE-ACA-55) · 8 kV (SE-ACA-80) | | Ionization range | Up to 200 mm (SE-ACA-55) · up to 400 mm (SE-ACA-80), with compressed air * | | Max. line speed | 300 m/min (SE-ACA-55) · 500 m/min (SE-ACA-80) | | Ordering length | 100 – 2000 mm in 100 mm steps | | Air connection | 10 mm hose | | Air pressure — dry filtered air | 2 bar (8 bar max.) | | Pin current (safety) | < 100 μA — shockless (both versions) | | Transformer current | Max. 5 mA (with fuse) | | Emitter pin material | Stainless steel — long service life | | Polarity | Alternating AC | | Cable | C2: 2 m HFFR-protected cable with HV connector | | Bars per power unit | Up to 2 or 4 per SE-PAC (2- or 4-output version), within 12 m total length of cables and bars | | Environment | Max. 60 °C · 70 % rH non-condensing max. | | Protection class | IP66 — fully sealed | | Housing | Washable, industrial-grade | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | * Ionization range measured at standard conditions (20 °C, 50 % rH, with compressed air). Effective range may vary with air pressure, humidity, temperature and line speed. ### Applications - 3D plastic parts & moulded components: Deliver ions into cavities, recesses and inner surfaces of moulded plastic parts. - Wide-gap machine installations: Mount the bar up to 400 mm (SE-ACA-80) or 200 mm (SE-ACA-55) from the material where machine geometry or guarding prevents close positioning. - Injection mould entry zones: Deliver ionized air into the mould area to neutralise parts as they are ejected. - High-speed film & web lines: Neutralise films, paper webs and foils at up to 500 m/min (SE-ACA-80) or 300 m/min (SE-ACA-55) at extended bar-to-material distances. - Automotive interior plastics: Eliminate static on large plastic panels and trim before paint or final assembly. - Wide-web converting: Cover the full width of wide webs from a fixed bar position. Industries: Plastics (3D parts, moulded components, thick sheet); Automotive (panels, trim, interior assembly); Printing & converting; Film & flexible packaging; Thermoforming & extrusion; Electronics; Paper & board. ### Complete system - SE-ACA bar (specify length): Long-range ionizing bar with integrated air channel - SE-PAC-55-2-C / -4-C or SE-PAC-80-2-C / -4-C: Required — 2 or 4 output AC power unit: 5.5 kV for the SE-ACA-55, 8 kV for the SE-ACA-80 - Compressed air supply: Dry, filtered air at 2 bar (8 bar max.) via 10 mm hose - SE-CAB-AC-1 extension cable (optional): Non-standard cable lengths in 1 m steps within the 12 m total length per power unit ### FAQ Q: What is the difference between the SE-ACA and the SE-ACB-80? A: Both are AC bars on the SE-PAC system. The SE-ACB-80 is a passive bar with a range of up to 250 mm; the SE-ACA adds an integrated air channel that carries the ions to 400 mm (SE-ACA-80) and into 3D cavities. Q: What is the difference between the SE-ACA and the SE-DCA-110? A: The SE-ACA uses AC technology and an SE-PAC power unit. The SE-DCA-110 uses pulsed DC from 24 V DC and reaches up to 1000 mm with compressed air. Q: Can I use an SE-PAC-55 with the SE-ACA? A: Yes, with the 5.5 kV SE-ACA-55. The 8 kV SE-ACA-80 requires an SE-PAC-80. Q: Can the bar be used without compressed air? A: It then works as a passive AC bar and does not reach the specified range. Without air, the SE-ACB bars are the recommended alternative. Q: How many SE-ACA bars can I connect to one SE-PAC power unit? A: Up to 2 on the 2-output and up to 4 on the 4-output SE-PAC, within the 12 m total length of cables and bars. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-aca-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-aca-manual-en.pdf - Dimensional drawing SE-ACA-80 (8 kV): https://foge-antistatic.com/downloads/drawings/foge-se-aca-dimensional-drawing-en.pdf - Dimensional drawing SE-ACA-55 (5.5 kV): https://foge-antistatic.com/downloads/drawings/foge-se-aca-55-dimensional-drawing-en.pdf ## SE-DCB-90 Pulsed DC Antistatic Bar – 9 kV URL: https://foge-antistatic.com/products/static-electricity/static-elimination/se-dcb-90/ Category: Static elimination · Family: Pulsed DC antistatic bars Compact 9 kV pulsed DC static elimination — no HV transformer, 24 V DC supply, up to 200 mm range. The FÖGE SE-DCB-90 is a compact, high-efficiency 9 kV pulsed DC antistatic bar designed for reliable static elimination in industrial production — without an external high-voltage power unit. The bar operates from a standard 24 V DC supply (SE-PSU-24-C-M12, sold separately) and generates its 9 kV ionization voltage internally. This eliminates HV transformers, high-voltage cabling and the associated safety zones, making the SE-DCB-90 straightforward to integrate into new machines, existing lines and robotic systems. It neutralises static at 25 – 200 mm from the bar on non-conductive materials including plastic parts, film, glass and packaging. The SE-DCB-90 uses balanced alternating pulsed DC ionization — continuously switching between positive and negative ion output for fast, complete neutralisation of both positive and negative charges. Shockless tungsten emitter pins provide a long service life with minimal maintenance. An integrated LED indicator shows power, ionization and fault status, and an M12 connector for a standard 4-pin M12 cable ensures a reliable connection. The bar can be ordered in any length from 300 mm to 4500 mm. ### Key features - 9 kV pulsed DC ionization — generated internally from 24 V DC; no external HV transformer or HV cabling - Ionization range 25 – 200 mm — for conveyors, 3D parts, packaging and short-to-medium standoff installations - Orderable in any length from 300 mm to 4500 mm - 24 V DC supply — connects to the SE-PSU-24-C-M12 adapter (sold separately) - No compressed air required — passive ionizing bar - Shockless design — tungsten emitter pins, safe for operators - Balanced alternating pulsed DC — fast, complete neutralisation of positive and negative charges - Integrated LED status indicator — power, ionization and fault status - M12 connector for a 4-pin M12 cable — cable ordered separately - Industrial-grade, impact-resistant housing for continuous-duty production ### How it works The SE-DCB-90 connects to a 24 V DC supply via a 4-pin M12 cable. Internally, the bar's pulsed DC circuit converts the 24 V input to 9 kV, which is applied to the row of tungsten emitter pins. The elevated voltage ionizes the surrounding air at each pin tip, generating a dense cloud of ions. The circuit continuously alternates between positive and negative high-voltage pulses — producing a balanced mixture of ions that drift outward from the bar towards the target material. When these ions reach a charged surface, those of opposite polarity are attracted to the charge and neutralise it. The alternating design ensures that neither polarity is over-neutralised, leaving the surface close to zero volts. The shockless circuit keeps emitter pin current at a safe level at all times. ### Which product to choose — SE-DCB-90, SE-DCA-110 or SE-ACB-80 | Parameter | SE-DCB-90 | SE-DCA-110 | SE-ACB-80 | |---|---|---|---| | Technology | 9 kV pulsed DC | 11 kV pulsed DC + compressed air | 8 kV AC — requires SE-PAC-80 | | Ionization range | 25 – 200 mm | Up to 1000 mm | Up to 250 mm | | Air required | No | Yes — min. 2 bar, ⌀ 8 mm hose | No | | Power supply | 24 V DC (SE-PSU-24-C-M12) | 24 V DC (SE-PSU-24-C-M12) | SE-PAC-80 HV power unit | | Connector | M12 (4-pin cable) | M12 (4-pin cable) | HV plug-and-play connector | | Length range | 300 – 4500 mm | 300 – 2000 mm | 100 – 4500 mm | | Best for | Conveyors, robotics, bins, printing and packaging — medium range, no air | Winding systems, moulds, conveyors — long range where air is available | High-speed film and web lines requiring AC ionization | ### Electrical connection — M12 | Pin | Function | |---|---| | 1 | +24 V DC | | 2 | Not used | | 3 | 24 V− (GND) | | 4 | Fault output | Use a 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable. Pin 2 is not used. Pin 4 provides a fault output signal for external fault indication. Do not connect or disconnect while power is applied. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-DCB-90-xxxx (length in mm, e.g. SE-DCB-90-0600 = 600 mm) | | Power supply (sold separately) | SE-PSU-24-C-M12 (220 V AC to 24 V DC) | | Ionization type | Pulsed DC — shockless | | Pin current (safety) | < 250 μA | | Ionization output voltage | 9 kV pulsed DC | | Operating voltage | 24 V DC (21 – 28 V) · 0.5 A max. | | Ionization range | 25 – 200 mm * | | Ordering length | 300 – 4500 mm (custom lengths on request) | | Emitter pin material | Tungsten — extremely long lifetime | | Polarity | Alternating pulsed DC — balanced ion output | | Connector | M12 — use a 4-pin M12 cable (order separately) | | Status indicator | Integrated LED — power, ionization and fault status | | Operating temperature | 0 – 50 °C | | Max. humidity | 70 % rH, non-condensing | | Protection class | IP65 (with connector) | | Housing | Industrial-grade, impact-resistant | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | * Ionization range measured under standard conditions (20 °C, 50 % rH). Effective range may vary with ambient humidity, temperature and line speed. ### Applications - Bottle & part conveyors: Neutralise static on bottles, containers, trays and moulded parts on conveyor lines — mounted at a distance where close positioning is not possible. - Plastic & glass 3D components: Eliminate static from complex 3D-shaped plastic, glass and composite components before assembly, coating or quality inspection. - Printing & converting lines: Control static on paper, film, foil and board before and during printing, laminating and slitting — preventing ink smear, misalignment and dust attraction. - Digital packaging & labelling equipment: Remove static from packaging film, labels and folding cartons — improving seal integrity, label placement accuracy and machine reliability. - Robotic ionization systems: Mount on robotic arms or fixed frames in automated handling cells — delivering static-free surfaces to mouldings, electronic housings and optical components. - ESD operator stations & collection bins: Provide continuous static elimination at manual assembly stations and material bins — protecting ESD-sensitive components and preventing materials from clumping. Industries: Plastics & packaging; Printing & converting; Pharmaceutical & medical devices; Electronics & ESD-sensitive assembly; Automotive (plastic components); Food & beverage (bottle and container lines); Robotics & industrial automation. ### Complete system - SE-DCB-90 bar (specify length): Order in required length (300 – 4500 mm). Example: SE-DCB-90-0600 = 600 mm - SE-PSU-24-C-M12 power supply: 220 V AC to 24 V DC adapter, M12 version — required · sold separately - 4-pin M12 cable: Industrial M12 connection cable — length to suit installation · sold separately - Mounting brackets (optional): Standard and custom brackets — contact FÖGE for options - Maintenance kit (optional): FÖGE Antistatic Maintenance Kit — cleaning tools and spare tungsten emitter pins ### FAQ Q: Does the SE-DCB-90 require a high-voltage power unit? A: No. The bar generates its 9 kV ionization voltage internally from a 24 V DC supply. The SE-PSU-24-C-M12 adapter (220 V AC to 24 V DC) is required and sold separately — but no external HV transformer, HV cabling or HV safety zones are needed. Q: What is the difference between the SE-DCB-90 and the SE-DCA-110? A: The SE-DCA-110 has integrated compressed air nozzles that extend its ionization range to 1000 mm at 11 kV. The SE-DCB-90 is a passive bar (no air required) with a 9 kV output and 25 – 200 mm working distance. Choose the SE-DCB-90 where compressed air is not available or not needed; choose the SE-DCA-110 where maximum range is required. Q: What is the difference between the SE-DCB-90 and the SE-ACB-80? A: The SE-DCB-90 is a pulsed DC bar powered by 24 V DC — no external HV power unit is needed. The SE-ACB-80 is an AC bar requiring an SE-PAC-80 external HV power unit, with a 250 mm range at 8 kV AC, designed for high-speed web applications. The SE-DCB-90 is better suited where no HV infrastructure is available and for conveyor, robotic and 3D-part applications. Q: What length should I order? A: The bar should span at least the full width of the material or zone to be neutralised. It is orderable from 300 mm to 4500 mm. Q: Is compressed air required? A: No. The SE-DCB-90 is a passive ionizing bar — ions drift from the emitter pins to the target surface without air assist, which makes it simpler to install and maintain. Q: Can the SE-DCB-90 be used on a robotic arm? A: Yes. The compact 24 V DC design, M12 connector and absence of external HV components make it well suited for robotic arm mounting and automated handling cells. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-dcb-90-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-dcb-90-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-dcb-90-dimensional-drawing-en.pdf ### 3D applications - Pilot 3D — Film slitting with SE-DCB-90: https://foge-antistatic.com/applications/film-slitting-se-dcb-90/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-film-slitting-se-dcb-90-application-sheet-en.pdf) - Inkjet coding line with SE-DCB-90: https://foge-antistatic.com/applications/inkjet-coding-se-dcb-90/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-inkjet-coding-se-dcb-90-application-sheet-en.pdf) - VFFS bagging machine with 3 × SE-DCB-90: https://foge-antistatic.com/applications/vffs-bagging-se-dcb-90/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-vffs-bagging-se-dcb-90-application-sheet-en.pdf) - Face mask line with 4 × SE-DCB-90: https://foge-antistatic.com/applications/face-mask-production-se-dcb-90/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-face-mask-production-se-dcb-90-application-sheet-en.pdf) - Sleeve wrapper with SE-DCB-90: https://foge-antistatic.com/applications/sleeve-wrapper-se-dcb-90/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-sleeve-wrapper-se-dcb-90-application-sheet-en.pdf) - Wrap-around labeller with 2 × SE-DCB-90: https://foge-antistatic.com/applications/wrap-around-labelling-se-dcb-90/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-wrap-around-labelling-se-dcb-90-application-sheet-en.pdf) - Front & back labeller with 2 × SE-DCB-90: https://foge-antistatic.com/applications/front-back-labelling-se-dcb-90/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-front-back-labelling-se-dcb-90-application-sheet-en.pdf) ## SE-DCB-110 Pulsed DC Antistatic Bar – 11 kV URL: https://foge-antistatic.com/products/static-electricity/static-elimination/se-dcb-110/ Category: Static elimination · Family: Pulsed DC antistatic bars Long-range static elimination at 100 – 600 mm — 11 kV pulsed DC, 24 V DC supply, no HV transformer. The FÖGE SE-DCB-110 is a compact, high-power 11 kV pulsed DC antistatic bar designed for long-range static elimination in demanding industrial environments. Operating directly from a 24 V DC supply (SE-PSU-24-C-M12, sold separately), it generates its 11 kV ionization voltage internally — eliminating external high-voltage transformers, HV cabling and the safety zones they require. With an effective working distance of 100 – 600 mm, it is the right choice for film winding and unwinding, labelling and converting lines, injection mould entry areas, robotic installations and any application where the bar must be positioned well away from the target surface. The SE-DCB-110 uses balanced alternating pulsed DC ionization — continuously switching between positive and negative ion output to neutralise both charge polarities. Shockless tungsten emitter pins deliver consistent ion output with a long service life and minimal maintenance. An integrated LED indicator shows the operating status, and an M12 connector for a standard 4-pin M12 cable ensures a reliable connection. The bar can be ordered in any length from 300 mm to 4500 mm in 100 mm steps. ### Key features - 11 kV pulsed DC ionization — generated internally from 24 V DC; no external HV transformer or HV cabling - Effective working distance 100 – 600 mm — for long-range applications - Orderable from 300 mm to 4500 mm in 100 mm steps - 24 V DC supply (21 – 28 V) — connects to the SE-PSU-24-C-M12 adapter (sold separately) - No compressed air required — passive ionizing bar - Shockless design — tungsten emitter pins, safe for operators - Balanced alternating pulsed DC — fast, complete neutralisation of positive and negative charges - Integrated LED status indicator - M12 connector for a 4-pin M12 cable — cable ordered separately - IP65 industrial-grade, impact-resistant housing for continuous-duty production ### How it works The SE-DCB-110 connects to a 24 V DC supply via a 4-pin M12 cable. Internally, the bar's pulsed DC high-voltage circuit converts the 24 V input to 11 kV, which is applied to the row of tungsten emitter pins. The high voltage ionizes the air around each pin, generating a dense cloud of positive and negative ions. The circuit continuously alternates between positive and negative pulses, so the ion output is balanced and both charge polarities on the target surface are neutralised. The higher 11 kV voltage creates a denser ion field that reaches further than lower-voltage bars, giving an effective working distance of 100 – 600 mm. The shockless design keeps pin current at a safe level at all times. ### Which product to choose — SE-DCB-110, SE-DCB-90 or SE-DCA-110 All three products operate from 24 V DC with no external HV power unit. | Parameter | SE-DCB-110 | SE-DCB-90 | SE-DCA-110 | |---|---|---|---| | Voltage | 11 kV pulsed DC | 9 kV pulsed DC | 11 kV pulsed DC + air | | Working distance | 100 – 600 mm | 25 – 200 mm | Up to 1000 mm | | Air required | No | No | Yes — min. 2 bar | | Length range | 300 – 4500 mm | 300 – 4500 mm | 300 – 2000 mm | | Best for | Film winding, labelling, converting, robotics — long range, no air | Conveyors, bins, printing — short to medium range, no air | Winding, moulds, conveyors — maximum range where compressed air is available | ### Electrical connection — M12 | Pin | Function | |---|---| | 1 | +24 V DC | | 2 | Not used | | 3 | 24 V− (GND) | | 4 | Fault output | Use a 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable. Pin 2 is not used. Pin 4 provides a fault output signal for external fault indication. Do not connect or disconnect while power is applied. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-DCB-110-xxxx (length in mm, e.g. SE-DCB-110-0600 = 600 mm) | | Power supply (sold separately) | SE-PSU-24-C-M12 (220 V AC to 24 V DC) | | Ionization type | Pulsed DC — shockless | | Pin current (safety) | < 250 μA | | Ionization output voltage | 11 kV pulsed DC | | Operating voltage | 24 V DC (21 – 28 V) · 0.5 A max. | | Ionization range | 100 – 600 mm * | | Ordering length | 300 – 4500 mm in 100 mm steps | | Emitter pin material | Tungsten — extremely long lifetime | | Polarity | Alternating pulsed DC — balanced ion output | | Connector | M12 — use a 4-pin M12 cable (order separately) | | Status indicator | Integrated LED — power, ionization and fault status | | Operating temperature | 0 – 50 °C | | Max. humidity | 70 % rH, non-condensing | | Protection class | IP65 (with connector) | | Housing | Industrial-grade, impact-resistant | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | * Ionization range measured under standard conditions (20 °C, 50 % rH). Effective range may vary with ambient humidity, temperature and line speed. ### Applications - Film winders & unwinders: Neutralise static on plastic films and webs during winding and unwinding — where the bar must be mounted well away from the moving material. - Labelling & laminating lines: Eliminate static from labels, films and substrates before and during laminating and labelling — preventing misalignment, adhesion failures and contamination. - Converting lines: Control static on paper, film, foil and board during slitting, rewinding and converting. - Injection mould entry areas: Neutralise charge on plastic parts as they leave the mould — preventing dust attraction on freshly moulded surfaces. - Robotic arm installations: Mount on robotic arms or fixed frames in automated handling cells for long-range ionization of parts at varying positions. - Digital printing & slitting systems: Neutralise static on substrates before and during digital printing and slitting — preventing ink smear, misalignment and dust attraction. Industries: Plastics & film (winding, extrusion, converting); Printing & converting; Packaging (labelling, laminating, slitting); Pharmaceutical & medical devices; Electronics & ESD-sensitive assembly; Automotive (plastic components, large panels); Robotics & industrial automation. ### Complete system - SE-DCB-110 bar (specify length): Order in the required length (300 – 4500 mm, 100 mm steps). Example: SE-DCB-110-0600 = 600 mm - SE-PSU-24-C-M12 power supply: 220 V AC to 24 V DC adapter — required · sold separately - 4-pin M12 cable: Industrial M12 connection cable — length to suit installation · sold separately - Mounting brackets (optional): Standard and custom brackets — contact FÖGE for options - Maintenance kit (optional): FÖGE Antistatic Maintenance Kit — cleaning tools and spare tungsten emitter pins ### FAQ Q: Does the SE-DCB-110 require a high-voltage power unit? A: No. The bar generates its 11 kV ionization voltage internally from a 24 V DC supply. The SE-PSU-24-C-M12 adapter (220 V AC to 24 V DC) is required and sold separately — no external HV transformer, HV cabling or HV safety zones are needed. Q: What is the difference between the SE-DCB-110 and the SE-DCB-90? A: Both are passive pulsed DC bars with 24 V DC supply and no compressed air. The SE-DCB-110 operates at 11 kV with a working distance of 100 – 600 mm; the SE-DCB-90 operates at 9 kV with 25 – 200 mm. Choose the SE-DCB-110 when the installation requires a longer working distance. Q: What is the difference between the SE-DCB-110 and the SE-DCA-110? A: Both operate at 11 kV from 24 V DC with an M12 connector, but the SE-DCA-110 uses integrated compressed air to carry ions up to 1000 mm. The SE-DCB-110 is a passive bar without air. Choose the SE-DCB-110 where compressed air is not available or not wanted. Q: What length should I order? A: The bar should span at least the full width of the material or zone to be neutralised. The SE-DCB-110 is orderable from 300 mm to 4500 mm in 100 mm steps. Q: Is compressed air required? A: No. The SE-DCB-110 is a passive ionizing bar — no compressed air is needed at the installation point. Q: Can the SE-DCB-110 be used on a robotic arm? A: Yes. The compact 24 V DC design, M12 connector and absence of external HV components make it well suited for robotic arm mounting and automated handling cells. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-dcb-110-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-dcb-110-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-dcb-110-dimensional-drawing-en.pdf ### 3D applications - Film winder with 2 × SE-DCB-110: https://foge-antistatic.com/applications/film-winder-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-film-winder-se-dcb-110-application-sheet-en.pdf) - Converting line with 2 × SE-DCB-110: https://foge-antistatic.com/applications/web-handling-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-web-handling-se-dcb-110-application-sheet-en.pdf) - Blown film line with 2 × SE-DCB-110: https://foge-antistatic.com/applications/blown-film-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-blown-film-se-dcb-110-application-sheet-en.pdf) - Cross-cutting machine with 3 × SE-DCB-110: https://foge-antistatic.com/applications/cross-cutting-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-cross-cutting-se-dcb-110-application-sheet-en.pdf) - Medical moulding chute with SE-DCB-110: https://foge-antistatic.com/applications/medical-chute-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-medical-chute-se-dcb-110-application-sheet-en.pdf) - IML containers with SE-DCB-110: https://foge-antistatic.com/applications/iml-containers-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-iml-containers-se-dcb-110-application-sheet-en.pdf) - Blow moulding preforms with SE-DCB-110: https://foge-antistatic.com/applications/blow-moulding-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-blow-moulding-se-dcb-110-application-sheet-en.pdf) - Foam thermoforming line with 4 × SE-DCB-110: https://foge-antistatic.com/applications/foam-thermoforming-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-foam-thermoforming-se-dcb-110-application-sheet-en.pdf) - Warping machine with SE-DCB-110: https://foge-antistatic.com/applications/textile-warping-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-textile-warping-se-dcb-110-application-sheet-en.pdf) - Carding machine with SE-DCB-110: https://foge-antistatic.com/applications/textile-carding-se-dcb-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-textile-carding-se-dcb-110-application-sheet-en.pdf) ## SE-DCA-110 Pulsed DC Antistatic Bar with Compressed Air – 11 kV URL: https://foge-antistatic.com/products/static-electricity/static-elimination/se-dca-110/ Category: Static elimination · Family: Pulsed DC antistatic bars Long-range static elimination up to 1000 mm — compressed air-assisted ionization, 24 V DC, no HV transformer. The FÖGE SE-DCA-110 is a high-power 11 kV pulsed DC antistatic bar engineered for applications where standard ionizing bars cannot reach — delivering effective static elimination at distances up to 1000 mm through integrated compressed air assistance. By directing ionized air from the bar's nozzles at the target surface, the SE-DCA-110 extends its ionization reach far beyond what a passive bar can achieve. This makes it the right choice for film and plastic winding systems, injection mould cavities, automated conveyor lines, robotic handling systems and any installation where the bar must be positioned well away from the material surface. Unlike traditional HV ionizing systems, the SE-DCA-110 operates at 24 V DC — the 11 kV ionization voltage is generated internally, eliminating the need for an external high-voltage transformer or high-voltage cabling. The only external connections required are a 24 V DC power supply (SE-PSU-24-C-M12, sold separately) and a standard compressed air line (⌀ 8 mm hose, minimum 2 bar, dry filtered). The bar is available with a straight (-S) or L-type 90° (-L) air fitting and can be ordered in any length from 300 mm to 2000 mm. ### Key features - 11 kV pulsed DC ionization — high-power output for demanding long-range static elimination - Ionization range up to 1000 mm — compressed air carries ions to the target far beyond passive bars - 24 V DC operation — ionization voltage generated internally; no external HV transformer or HV cabling - Two air fitting variants: -S (straight ⌀ 8 mm) and -L (L-type / 90° ⌀ 8 mm) - Orderable in any length from 300 mm to 2000 mm - Shockless design — tungsten emitter pins, safe for operators - Balanced pulsed DC — alternating positive and negative ion output for fast, complete neutralisation - Integrated LED status indicator — operational and fault status at a glance - M12 connector for a 4-pin M12 cable — robust industrial connection; cable ordered separately - Compressed air connection: ⌀ 8 mm hose, minimum 2 bar, dry filtered - Industrial-grade, impact-resistant housing for continuous-duty production - EMC and Low Voltage Directive compliant: 2014/30/EU · 2014/35/EU ### How it works The SE-DCA-110 connects to a 24 V DC power supply (SE-PSU-24-C-M12) and a compressed air line. Internally, the bar's pulsed DC circuit generates 11 kV, which is applied to the tungsten emitter pins. The elevated voltage ionizes the air surrounding each pin, producing a dense, balanced cloud of positive and negative ions. Simultaneously, dry filtered compressed air is fed into the bar's integrated air channel and expelled through nozzles along the bar's length towards the target surface. This airflow picks up the ions generated at the pins and carries them at high velocity across the working distance, allowing effective static neutralisation at distances up to 1000 mm. The pulsed DC circuit alternates polarity continuously, keeping the ion output balanced and preventing net charge build-up on the target. The shockless design limits emitter pin current to a safe level at all times. ### Which variant to choose — S or L fitting The two variants differ only in the air connection fitting. All other specifications are identical. | Parameter | SE-DCA-110-xxxx-S | SE-DCA-110-xxxx-L | |---|---|---| | Air fitting | Straight — ⌀ 8 mm hose | L-type (90°) — ⌀ 8 mm hose | | Fitting location | End of bar — hose exits parallel to bar axis | End of bar — hose exits at 90° to bar axis | | Best for | Standard installations with direct hose routing | Space-constrained installations where a straight hose run is blocked | ### Electrical connection — M12 | Pin | Function | |---|---| | 1 | +24 V DC | | 2 | Not used | | 3 | 24 V− (GND) | | 4 | Fault output | Use a 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable. Pin 2 is not used. Pin 4 provides a fault output signal for external fault indication. Do not connect or disconnect while power is applied. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-DCA-110-xxxx-S (straight fitting) · SE-DCA-110-xxxx-L (L-type fitting) — xxxx = length in mm | | Power supply (sold separately) | SE-PSU-24-C-M12 (220 V AC to 24 V DC) | | Ionization type | Pulsed DC — shockless | | Pin current (safety) | < 250 μA | | Ionization output voltage | 11 kV pulsed DC | | Operating voltage | 24 V DC (21 – 28 V) · 0.5 A max. | | Ionization range | 25 – 1000 mm * | | Ordering length | 300 – 2000 mm in 100 mm steps | | Air connection | ⌀ 8 mm hose — straight (-S) or L-type 90° (-L) fitting | | Air pressure | Minimum 2 bar · dry, filtered | | Air consumption | 205 l/min per 1000 mm length at 6 bar (scale proportionally by length) | | Emitter pin material | Tungsten — extremely long lifetime | | Polarity | Alternating pulsed DC — balanced ion output | | Connector | M12 — use a 4-pin M12 cable (order separately) | | Status indicator | Integrated LED — operational status | | Operating temperature | 0 – 50 °C | | Max. humidity | 70 % rH, non-condensing | | Protection class | IP65 (with connector) | | Housing | Industrial-grade, impact-resistant | | Mounting | FG-AC-0005 T-fixings (M6 × 40 mm stud and flange nut; 2 per bar up to 1000 mm, +1 per additional 500 mm) · 180° adjustable mounting bracket | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | * Ionization range up to 1000 mm measured under standard conditions (20 °C, 50 % rH) with clean dry compressed air at rated pressure. Effective range may vary with ambient humidity, temperature, air pressure and line speed. ### Applications - Film & plastic winding / unwinding: Neutralise static on PE, PP and PET webs during winding and unwinding — where the bar must be positioned at a large air gap from the moving web. - Inside injection moulds: Position the bar adjacent to or inside the mould cavity to neutralise static on freshly moulded parts — preventing dust attraction immediately after moulding. - Conveyor systems — bottles, trays, parts: Eliminate static on bottles, trays, containers and moulded parts on conveyors — where the bar cannot be mounted close to the product. - Digital printing, converting & slitting lines: Control static on substrates at high line speeds — where the wide air gap makes passive ionization insufficient. - Robotic & automated handling systems: Mount on robotic arms or fixed frames in automated handling cells — delivering long-range ionization to parts at varying positions. - Operator tables — white goods & electronics: Provide wide-area ionization above assembly tables — covering large panels, housings or appliance components from a single overhead bar. - Material collection bins: Neutralise static inside bins and hoppers — preventing clumping, sticking and electrostatic adhesion to bin walls. Industries: Plastics & film (winding, extrusion, thermoforming); Injection moulding; Printing, converting & slitting; Packaging (bottles, trays, rigid containers); Automotive (large plastic panels, interior components); Electronics & white goods assembly; Robotics & industrial automation. ### Complete system - SE-DCA-110 bar (variant + length): Specify variant (-S or -L) and length in mm (300 – 2000). Example: SE-DCA-110-0600-S = 600 mm, straight fitting - SE-PSU-24-C-M12 power supply: 220 V AC to 24 V DC power supply, M12 version — required · sold separately - M12 cable: Industrial M12 connection cable — length to suit installation · sold separately - Compressed air supply: Dry, filtered compressed air · ⌀ 8 mm hose · minimum 2 bar at the bar · customer-supplied - Mounting brackets (optional): Standard and custom brackets — contact FÖGE for options - Maintenance kit (optional): FÖGE Antistatic Maintenance Kit — cleaning tools and spare tungsten emitter pins ### FAQ Q: Does the SE-DCA-110 require a high-voltage power unit? A: No. The bar operates from a standard 24 V DC supply (SE-PSU-24-C-M12, sold separately). The 11 kV ionization voltage is generated internally — no external HV transformer, HV cabling or HV safety zones are needed. Q: What does the compressed air do — is this a dust-removal product? A: The primary function of the compressed air is to extend the ionization range. The air picks up the ions generated at the emitter pins and carries them across the working distance to the target surface — enabling effective static neutralisation at up to 1000 mm. Long-range static elimination is the design objective; the airflow is the means to achieve that reach, not a dust-removal system. Q: What is the difference between the -S and -L variants? A: Only the air connection fitting: -S has a straight ⌀ 8 mm hose fitting; -L has an L-type (90°) ⌀ 8 mm fitting. All electrical and ionization specifications are identical. Choose -L when machine geometry prevents a straight hose connection. Q: What length should I order? A: The bar should span at least the full width of the material or zone to be neutralised. It is orderable in any length from 300 mm to 2000 mm. Specify the length and variant (-S or -L) when ordering. Q: What are the compressed air requirements? A: Dry, filtered compressed air via a ⌀ 8 mm hose at a minimum of 2 bar. Air consumption is approximately 205 l/min per 1000 mm of bar length at 6 bar — scale proportionally for other lengths. Ensure the supply is free of moisture and oil. Q: Can the SE-DCA-110 be used on robotic arms? A: Yes. The compact 24 V DC design, lightweight construction and absence of external HV components make it well suited for robotic arms and end effectors. Contact FÖGE for bracket options. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-dca-110-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-dca-110-manual-en.pdf - Dimensional drawing SE-DCA-110-XXXX-S (straight air fitting): https://foge-antistatic.com/downloads/drawings/foge-se-dca-110-s-dimensional-drawing-en.pdf - Dimensional drawing SE-DCA-110-XXXX-L (90° elbow air fitting): https://foge-antistatic.com/downloads/drawings/foge-se-dca-110-l-dimensional-drawing-en.pdf ### 3D applications - Film winder with SE-DCA-110 (long distance): https://foge-antistatic.com/applications/film-winder-long-range-se-dca-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-film-winder-long-range-se-dca-110-application-sheet-en.pdf) - Foam sheet winder with SE-DCA-110: https://foge-antistatic.com/applications/foam-winder-se-dca-110/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-foam-winder-se-dca-110-application-sheet-en.pdf) ## SE-BLC-F-75-C Compact Antistatic Blower – Pulsed DC URL: https://foge-antistatic.com/products/static-electricity/static-elimination/se-blc-f-75-c/ Category: Static elimination · Family: Ionizing blowers Maintenance-free pulsed DC ionizing blower — no compressed air, no high-voltage power unit, automatic pin cleaning. The FÖGE SE-BLC-F-75-C is a compact, high-performance pulsed DC antistatic blower designed to eliminate static electricity at workstations, bench-top positions and light production line installations — without requiring compressed air or an external high-voltage power unit. Operating at 24 V DC, it connects directly to the optional SE-PSU-24-C-M12 power supply adapter, making installation straightforward wherever a standard 220 V AC outlet is available. An adjustable fan delivers a broad flow of ionized air across the target area up to 500 mm away, neutralising static charges on plastic components, PCBs, optical lenses, headlight covers and other non-conductive parts. The defining feature of the SE-BLC-F-75-C is its integrated automatic pin cleaning brush, which continuously keeps the tungsten emitter pins free from dust and contamination — the leading cause of ionization performance loss over time. An optional replaceable foam filter (10 PPI) protects both the fan and the ionizing system in dustier environments. Front panel buttons allow step-by-step fan speed adjustment, and a built-in display shows real-time fan speed level and ionization balance. ### Key features - Integrated automatic pin cleaning brush — maintains full ionization performance without manual intervention - Pulsed DC ionization — balanced positive and negative ion output for fast static elimination - 24 V DC powered — no external HV power unit required; connects to the SE-PSU-24-C-M12 adapter (sold separately) - No compressed air needed — built-in adjustable fan delivers ionized airflow across the target area - Ionization range up to 500 mm - Optional replaceable foam filter (10 PPI) — prevents fan and ionizing system contamination - Low noise operation — 38 dB typical; < 60 dB at 30 cm - Adjustable fan speed — front panel buttons for step-by-step airflow control - Tungsten emitter pins — extreme service life and consistent ion output - Built-in display — fan speed level and ionization balance; status indicators for power and fault - Adjustable 2-way mounting bracket — installation at custom angles - M12 5-pin connector — reliable industrial connection; cable ordered separately ### How it works The SE-BLC-F-75-C contains an integrated pulsed DC ionization unit that energises a row of tungsten emitter pins. The ionization circuit alternates between positive and negative high-voltage pulses, producing a balanced cloud of positive and negative ions. The adjustable fan draws ambient air through the optional foam filter, passes it over the ionizing pins, and delivers it as an ionized airflow across the target area. When this ionized airflow reaches a charged surface, ions of opposite polarity are attracted to the charge and neutralise it rapidly. The automatic pin cleaning brush sweeps the tungsten emitter pins continuously, removing dust that would otherwise reduce ionization output — ensuring consistent performance over the product's service life without manual maintenance. ### Fan blower vs compressed air ionizer — when to choose each | Parameter | SE-BLC-F-75-C (fan blower) | Compressed air ionizer | |---|---|---| | Air source | Built-in adjustable fan — no infrastructure needed | Requires compressed air line (4 – 8 bar, dry, filtered) | | Installation | 24 V DC socket — place anywhere | Requires compressed air routing to the workstation | | Ionization range | Up to 500 mm | Up to 300 mm+ depending on air pressure | | Airflow force | Gentle fan airflow — suits delicate components | High-velocity air blast — dislodges heavier particles | | Noise level | 38 dB typical | 73 – 83 dB typical | | Best for | Workstations, bench-top positions, cleanrooms, electronics, optics, light plastics | Removal of heavy dust from 3D-shaped parts before coating or assembly | | Pin maintenance | Automatic brush — maintenance-free | Manual pin cleaning at intervals | ### Electrical connection — M12 pin assignment | Pin | Function | |---|---| | 1 | +24 V DC supply | | 2 | Fault output | | 3 | GND | | 4 | Remote control | Use a 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-BLC-F-75-C | | Ionization type | Pulsed DC — shockless | | Pin current (safety) | < 250 μA | | Operating voltage | 24 V DC (21 – 28 V) via M12 connector · 0.4 A · max. 9 W | | Power supply (optional) | SE-PSU-24-C-M12 (220 V AC to 24 V DC) · not included | | Connector | M12, 5-pin (cable not included) | | Fan speed control | Front panel buttons — step-adjustable fan speed | | Fan type | Adjustable, double ball bearing — long lifetime, lightweight | | Pin cleaning | Integrated automatic cleaning brush — maintenance-free | | Filter | Replaceable foam filter, 10 PPI (optional) · protects fan and ionizing system | | Ionization range | Up to 500 mm * | | Decay time | 1 kV → 100 V in < 7 s at 500 mm | | LED indicators | Power · ionization · fault | | Noise level | < 60 dB(A) at 30 cm (typical: 38 dB) | | Emitter pin material | Tungsten — extremely long lifetime | | Polarity | Alternating pulsed DC (balanced ion output) | | Mounting | Adjustable 2-way mounting bracket | | Operating temperature | 0 – 50 °C | | Max. humidity | 70 % rH | | Housing | Industrial-grade, impact-resistant | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | * Ionization range measured under standard conditions (20 °C, 50 % rH) with fan at maximum speed. Effective range may vary with ambient temperature, humidity and fan speed setting. ### Applications - Electronics manufacturing & assembly: Neutralise static on PCBs, ESD-sensitive assemblies and electronic components at workstations — preventing dust attraction before soldering, inspection or packaging. - Plastic injection moulding & finishing: Remove static from freshly moulded plastic parts before finishing, painting or assembly — eliminating dust bonding on the part surface. - Optics & camera module assembly: Deliver static-free, low-velocity ionized airflow over lenses, sensor modules and optical components — where compressed air blast force is too aggressive. - Automotive headlights & interior trim: Eliminate static on headlight covers, reflectors and interior plastic components before assembly or quality inspection. - Cleanroom workbenches & operator desks: Provide continuous static-neutral airflow at cleanroom workstations — where quiet, filterable operation and minimal maintenance are essential. - Quality control & final inspection zones: Ensure parts are static-free before final inspection, measurement or packaging. Industries: Electronics & ESD-sensitive manufacturing; Optics, photonics & precision assembly; Automotive (interior plastics, headlights); Plastic injection moulding & finishing; Medical devices & cleanroom manufacturing; Printing & packaging (manual inspection stations); Semiconductors & wafer handling. ### Complete system - SE-BLC-F-75-C blower: Ionizing blower unit — integrated fan, auto pin-cleaning brush, front panel buttons, display, mounting bracket - SE-PSU-24-C-M12 power supply: 220 V AC to 24 V DC power supply adapter — required to power the blower · sold separately - M12 4-pin cable: Industrial M12 connection cable — specify length when ordering · sold separately - Foam filter (optional): Replaceable 10 PPI foam filter — protects fan and ionizing system in dusty environments - Maintenance kit (optional): FÖGE Antistatic Maintenance Kit — cleaning tools and spare tungsten emitter pins ### FAQ Q: Does the SE-BLC-F-75-C need an external high-voltage power unit? A: No. The SE-BLC-F-75-C operates at 24 V DC and contains its own integrated pulsed DC ionization circuit. The SE-PSU-24-C-M12 adapter (220 V AC to 24 V DC) is needed to power the blower and is sold separately. Q: What does automatic pin cleaning mean and why does it matter? A: Over time, dust settles on the emitter pins of an ionizer and degrades ionization performance. The SE-BLC-F-75-C has an integrated mechanical brush that continuously sweeps the emitter pins during operation — removing dust automatically without manual cleaning. This makes the blower virtually maintenance-free under normal operating conditions. Q: Is compressed air required? A: No. The SE-BLC-F-75-C uses its own built-in adjustable fan to deliver ionized airflow to the target. It only requires a 24 V DC power connection via the SE-PSU-24-C-M12 adapter. Q: What is the optional foam filter for? A: The replaceable 10 PPI foam filter sits at the air intake and prevents airborne dust from entering the fan and ionizing chamber. It is recommended in dusty production environments and should be replaced when visibly contaminated. Q: What cable connector does the SE-BLC-F-75-C use? A: An M12, 5-pin industrial connector. The cable is not included — order the appropriate M12 cable length separately. Q: Is the blower suitable for cleanroom use? A: The SE-BLC-F-75-C is well suited to cleanroom-adjacent and controlled-environment workstations thanks to its quiet operation, optional foam filter and low-velocity airflow. For certified cleanroom classifications, contact FÖGE to confirm suitability for your specific cleanliness class. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-blc-f-75-c-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-blc-f-75-c-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-blc-f-75-c-dimensional-drawing-en.pdf ### 3D applications - Headlight electronics with SE-BLC: https://foge-antistatic.com/applications/headlight-electronics-se-blc/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-headlight-electronics-se-blc-application-sheet-en.pdf) - Headlight coating prep with SE-BLC: https://foge-antistatic.com/applications/headlight-coating-prep-se-blc/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-headlight-coating-prep-se-blc-application-sheet-en.pdf) - Headlight housing station with SE-ACG + SE-BLC: https://foge-antistatic.com/applications/headlight-housing-assembly-se-acg-blc/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-headlight-housing-assembly-se-acg-blc-application-sheet-en.pdf) ## SE-BLA Multi Fan AC Blower Static Eliminator URL: https://foge-antistatic.com/products/static-electricity/static-elimination/se-bla/ Category: Static elimination · Family: Ionizing blowers 220 V AC mains-powered long-range ionizing blower — up to approx. 1 metre range, potentiometer fan control, for conveyors, assembly stations and 3D objects. The FÖGE SE-BLA is a multi-fan AC blower static eliminator designed for long-range static neutralisation of 3D objects, conveyor lines and assembly stations — applications where a flat antistatic bar mounted close to a surface is impractical or impossible. The unit connects directly to a 220 V AC mains supply and is entirely self-contained: it generates its own high-voltage AC ionization internally and uses multiple integrated fans to project the ion cloud to an effective range of approximately one metre. No external HV power unit, no compressed air supply and no additional infrastructure are required. The multiple fans produce a high-volume airflow that carries balanced positive and negative ions away from the unit and distributes them broadly across the target area. This wide ion delivery is particularly effective on 3D-shaped objects — bottles, boxes, moulded parts, components in bins — where ions must reach around corners, into recesses and onto several faces at once. Fan speed is adjusted continuously with a potentiometer on the unit, so air volume and ion delivery can be tuned to the working distance and the sensitivity of the application. The SE-BLA is available in five lengths with 2 to 6 fans. ### Key features - Effective ionization range up to approx. 1 metre — long-range static elimination without compressed air - 220 V AC mains supply — self-contained unit, no separate HV power unit required - Integrated multiple fans (2 – 6 depending on length) — high air volume distributes ions across 3D objects and wide areas - Fan speed control via potentiometer — stepless adjustment of air volume and ion delivery distance - Five lengths: 550 / 800 / 1000 / 1250 / 1500 - High-voltage AC ionization — balanced positive and negative ion output - Stainless steel emitter pins — long service life, shockless design (pin current < 250 μA) - Effective on 3D objects, complex shapes and parts in bins - Suitable for conveyors, assembly stations and robotic handling zones ### How it works The SE-BLA connects to a 220 V AC mains supply. Internally, a high-voltage AC ionization circuit applies AC high voltage to a row of stainless steel emitter pins. The high voltage ionizes the air immediately around the pins and generates balanced positive and negative ions — the same principle as the SE-ACB bars, but without an external SE-PAC power unit, because the HV generation is built into the SE-BLA. The integrated fans draw in ambient air, push it through the ionization zone and project the ions towards the target as a broad, high-volume air stream that reaches up to approximately one metre. The potentiometer controls the fan speed: at maximum speed the air volume is highest and ions are carried furthest; at reduced speed the airflow is gentler and suits lightweight or sensitive parts. The alternating AC polarity produces positive and negative ions continuously in balance. ### Variants and dimensions A = overall housing length, B = height, C = depth (see dimensional drawing). Mounting brackets: 4 × ⌀ 9 mm holes. | Product | Fans | A (mm) | B (mm) | C (mm) | |---|---|---|---|---| | SE-BLA-F-550-C | 2 | 545 | 200 | 185 | | SE-BLA-F-800-C | 3 | 805 | 200 | 185 | | SE-BLA-F-1000-C | 4 | 1065 | 200 | 185 | | SE-BLA-F-1250-C | 5 | 1325 | 200 | 185 | | SE-BLA-F-1500-C | 6 | 1585 | 200 | 185 | ### Which blower to choose — SE-BLA, SE-BLC or SE-BLL | Parameter | SE-BLA (this product) | SE-BLC-F-75-C | SE-BLL | |---|---|---|---| | Technology | AC ionization | Pulsed DC ionization | Pulsed DC ionization | | Power supply | 220 V AC mains — self-contained | 24 V DC (SE-PSU-24-C-M12) | 24 V DC (SE-PSU-24-C-M12) | | HV unit required | No — built-in | No — built-in | No — built-in | | Air source | Integrated multiple fans | Integrated single fan | Integrated fans — laminar flow | | Fan control | Potentiometer — stepless | Front panel buttons | Front panel buttons ▲ / ▼ | | Effective range | Approx. 1000 mm | Approx. 500 mm | Up to 1000 mm | | Air flow type | High-volume broad distribution | Compact directional | Wide laminar sheet | | Best for | Conveyors, assembly stations, 3D objects at distance | Compact installations, robotic arms, ESD stations | Wide work areas — uniform laminar coverage at distance | ### Installation notes - Mount the SE-BLA above or beside the target zone — typically 500 – 1000 mm from the target objects, depending on the required ionization intensity and the fan speed setting. Use a sturdy bracket rated for the unit's weight. - Connect the unit to a 220 V AC 50 Hz mains supply. Ensure the mains circuit is protected by an appropriate fuse or circuit breaker. - Set the potentiometer to minimum before switching on, then increase the fan speed gradually until the required ion delivery is reached at the working distance. Verify the static level at the target with an SE-SFM-030 fieldmeter. - On conveyors, direct the ion air stream at the product just before it reaches the critical process station (inspection, assembly or packaging). ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-BLA-F-xxxx-C (order length 550 / 800 / 1000 / 1250 / 1500) | | Variants | SE-BLA-F-550-C (2 fans) · SE-BLA-F-800-C (3 fans) · SE-BLA-F-1000-C (4 fans) · SE-BLA-F-1250-C (5 fans) · SE-BLA-F-1500-C (6 fans) | | Mains supply | 220 V AC · 50 Hz — self-contained, no separate HV power unit required | | Ionization type | AC — high voltage, shockless | | Pin current (safety) | < 250 μA | | Ionization performance | 1 kV → 100 V in < 7 s at 1000 mm distance | | Effective ionization range | Up to approx. 1000 mm (depends on fan speed setting) | | Air source | Integrated multiple fans — no compressed air required | | Fan speed adjustment | Potentiometer on the panel — stepless | | Controls | ON/OFF switch · fan speed potentiometer | | Fuse | F0.5AL250V fast-blow glass fuse, 5 × 20 mm | | Emitter pin material | Stainless steel — long service life, shockless design | | Polarity | Alternating AC — balanced positive and negative ion output | | Environment | 0 – 60 °C · max. 70 % rH | | Housing | Industrial-grade | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | ### Applications - Conveyor lines — 3D part neutralisation: Mount above a conveyor to deliver ions to passing 3D objects — bottles, boxes, moulded parts — at up to approx. 1 metre distance. The broad ion distribution reaches all faces of the object as it passes the unit. - Assembly stations: Continuous static elimination at manual assembly workstations where operators handle plastic components. The ion cloud neutralises the parts as well as the operator's hands and tools. - Robotic handling cells: Mount in fixed positions within robotic cells to neutralise plastic components as they are picked, placed or transferred. - Injection moulded part collection: Position above or beside part collection bins and conveyor exits of injection moulding machines to neutralise freshly moulded parts as they accumulate. - Quality inspection stations: Install above inspection stations where clean, static-free surfaces are required for visual or automated optical inspection. - Packaging lines — component loading: Neutralise components and packaging materials at loading and assembly stations — preventing static from attracting dust before the parts are sealed in the final package. Industries: Plastics & injection moulding (part collection, conveyor neutralisation); Electronics & ESD-sensitive assembly (operator stations, component handling); Automotive (plastic component assembly, conveyor lines); Packaging (component loading, material handling); Robotics & industrial automation (robotic cell static control); Medical devices & pharmaceutical (cleanroom-adjacent assembly); Consumer products manufacturing (assembly lines, quality inspection). ### Complete system - SE-BLA blower (select length): SE-BLA-F-550-C / -800-C / -1000-C / -1250-C / -1500-C — 2 to 6 fans - 220 V AC mains connection: 220 V AC 50 Hz plug connection — no separate HV power unit and no compressed air required - SE-SFM-030 fieldmeter (recommended): Verify static levels at the target surface while setting the fan speed ### FAQ Q: Does the SE-BLA require a separate HV power unit (SE-PAC)? A: No. The SE-BLA is self-contained. The HV AC ionization circuit is built into the unit. Connect it to a 220 V AC mains outlet — no SE-PAC, no 24 V DC supply and no compressed air are needed. Q: Does the SE-BLA require compressed air? A: No. The SE-BLA uses its own integrated fans to move air, so no compressed air supply is required at the installation point. Q: What is the difference between the SE-BLA and the SE-BLC? A: The SE-BLA is a 220 V AC mains unit with multiple fans, potentiometer control and approximately 1 metre range — for wide-area, long-range coverage of 3D objects, conveyors and assembly stations. The SE-BLC is a compact 24 V DC pulsed DC blower with a single fan and front panel button control and approximately 500 mm range, for compact installations such as robotic arms and ESD workstations. Q: What is the difference between the SE-BLA and the SE-BLL? A: The SE-BLA produces a broad, high-volume ion cloud from multiple fans — ideal for 3D objects and wide open areas at up to approx. 1 metre. The SE-BLL produces a wide, uniform laminar sheet of ionized air from a bar-format unit — ideal where even ion distribution across a full-width flat surface is required. Q: How do I set the correct fan speed? A: Start at low fan speed and increase gradually while monitoring static levels at the target with an SE-SFM-030 fieldmeter. The correct setting is the lowest fan speed that achieves the required static reduction at the working distance — this minimises air disturbance of lightweight parts and reduces noise. Q: Can the SE-BLA be used in a cleanroom? A: The SE-BLA is an industrial-grade unit designed for manufacturing environments. For certified cleanroom applications, contact FÖGE to discuss requirements and suitable alternatives. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-bla-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-bla-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-bla-dimensional-drawing-en.pdf ## SE-BLL Laminar Air Blower Ionizer URL: https://foge-antistatic.com/products/static-electricity/static-elimination/se-bll/ Category: Static elimination · Family: Ionizing blowers Wide-area pulsed DC static elimination up to 1000 mm — five lengths, no compressed air, replaceable ionizer module. The FÖGE SE-BLL is a laminar flow pulsed DC ionizing blower designed for wide-area static elimination at workstations, production line positions and precision assembly areas — without compressed air or an external high-voltage power unit. Powered by 24 V DC via the SE-PSU-24-C-M12 power supply (sold separately), the SE-BLL drives a uniform laminar airflow along the full length of the unit and delivers ionized air to the target surface at distances up to 1000 mm. This reach makes it the right tool for covering wide workbenches, large plastic parts, screen and optical assemblies and ESD-sensitive electronics areas from a single overhead position. The SE-BLL is available in five lengths from 530 to 2130 to match the width of the work area or machine. All variants share the same core design: tungsten emitter pins for a long service life; a replaceable ionizer module, so the ionization assembly can be exchanged at service without replacing the entire unit; and a replaceable 10 PPI foam filter that protects the fans and the ionizing system in dusty environments. An M12 5-pin industrial connector provides the power and signal connection. ### Key features - Ionization range up to 1000 mm — covers wide workbenches and large parts from a single position - Five lengths: SE-BLL-F-530-C / -700-C / -1055-C / -1420-C / -2130-C — match the unit to the width of the work area - Integrated pulsed DC ionization — balanced positive and negative ion output - 24 V DC powered — no HV power unit required; SE-PSU-24-C-M12 adapter sold separately - No compressed air needed — laminar fan-driven airflow carries the ions to the target - Replaceable ionizer module — service the ionization assembly without replacing the full unit - Replaceable foam filter (10 PPI) — protects fans and ionizing system from dust - Quiet operation — 38 – 40 dB at 1000 mm depending on length - Fan speed set with the ▲ / ▼ front panel buttons — step-adjustable airflow for different working distances - LED status indicators — 24 V supply, ionization status, fan speed level - Adjustable 2-way mounting bracket — bottom or rear mounting - M12 5-pin connector — use a 4-pin M12 cable (sold separately) ### How it works The SE-BLL contains an integrated pulsed DC ionization unit that energises a row of tungsten emitter pins along the full length of the unit. The pulsed DC circuit alternates between positive and negative high-voltage pulses and generates a continuously balanced cloud of positive and negative ions. The built-in fans draw ambient air through the foam filter and push it through the unit in a laminar (smooth, parallel) flow — carrying the ions in a wide, even sheet of ionized air to the target surface. When the ionized air reaches a charged surface, ions of the opposite polarity neutralise the charge rapidly and evenly across the full width of the ionized air outlet. The fan speed is adjusted step by step with the front panel buttons to match the airflow to the working distance. ### Variants, performance and dimensions Cross-section: 119 mm wide, 123 mm housing height, 233.5 mm including bracket (see dimensional drawing). | Product | Power consumption | Air flow speed at 1000 mm | Noise level at 1000 mm | Ionized air outlet A (mm) | B (mm) | Overall length C (mm) | |---|---|---|---|---|---|---| | SE-BLL-F-530-C | 18 W | 1.6 m/s | 38 dB | 541 | 53 | 684 | | SE-BLL-F-700-C | 21 W | 2.1 m/s | 39 dB | 711 | 53 | 854 | | SE-BLL-F-1055-C | 19 W | 3.1 m/s | 40 dB | 1066 | 53 | 1209 | | SE-BLL-F-1420-C | 31 W | 2.1 m/s | 40 dB | 1431 | 53 | 1649 | | SE-BLL-F-2130-C | 39 W | 3.1 m/s | 40 dB | 2141 | 53 | 2359 | ### Which length to choose | Model | Typical coverage width | Best for | |---|---|---| | SE-BLL-F-530-C | Up to 500 mm | Single operator workstation, small PCB or component tray, narrow conveyor | | SE-BLL-F-700-C | Up to 650 mm | Standard workbench position, medium electronics assembly area | | SE-BLL-F-1055-C | Up to 1000 mm | Wide workbench, dual-operator station, medium conveyor or inspection line | | SE-BLL-F-1420-C | Up to 1350 mm | Large machine installation, automotive trim or headlight inspection station | | SE-BLL-F-2130-C | Up to 2000 mm | Extra-wide bench or machine, full-width coverage of large plastic or optical parts | ### Electrical connection — M12 pin assignment | Pin | Function | |---|---| | 1 | +24 V DC supply | | 2 | Fault output | | 3 | GND | | 4 | Remote control | Use a 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-BLL-F-xxxx-C (530 / 700 / 1055 / 1420 / 2130) | | Power supply (sold separately) | SE-PSU-24-C-M12 (220 V AC to 24 V DC) | | Operating voltage | 24 V DC (21 – 28 V) | | Ionization type | Pulsed DC — shockless | | Pin current (safety) | < 250 μA | | Ionization range | Up to 1000 mm | | Ionization performance | 1 kV → 100 V in < 7 s at 1000 mm distance | | Fan speed adjustment | Front panel buttons (▲ / ▼) — step-adjustable | | Emitter pin material | Tungsten — extremely long lifetime | | Pin cleaning | Manual — remove the front cover and clean the tungsten pins with the brush of the FÖGE maintenance kit | | Ionizer module | Replaceable — the full unit does not need to be replaced at service | | Filter | Replaceable foam filter, 10 PPI | | Polarity | Alternating pulsed DC — balanced ion output | | Connector | M12, 5-pin (cable not included) | | LED indicators | 24 V supply · ionization status (green: OK, red: fault) · fan speed level | | Controls | Power button · fan speed buttons ▲ / ▼ | | Ground terminal | Yes — do not operate without connecting the ground terminal to earth | | Mounting | Adjustable 2-way mounting bracket — bottom or rear mounting · 4 × ⌀ 9 mm holes | | Operating temperature | 0 – 50 °C | | Max. humidity | 70 % rH | | Housing | Industrial-grade, impact-resistant | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | Ionization range measured under standard conditions (20 °C, 50 % rH) with fans at maximum speed. Effective range may vary with ambient temperature, humidity and fan speed setting. Air flow speed and noise level are measured at 1000 mm. ### Applications - ESD workbenches & electronics assembly: Continuous wide-area ionized airflow above PCB assembly benches, component handling areas and ESD-sensitive workstations. - Plastic components & finishing lines: Neutralise static on injection-moulded plastic parts, covers and housings before painting, coating or assembly — preventing dust from bonding to freshly moulded surfaces. - Optical parts & screen assembly: Gentle, uniform ionized airflow across lenses, screens, sensor modules and optical components — where high-velocity compressed air is too aggressive and point ionizers leave uncovered areas. - Automotive lighting & interior trim: Eliminate static on headlight assemblies, reflectors and interior plastic panels before assembly or quality inspection — covering the full width of wide parts from one overhead position. - Cleanroom & controlled-environment workstations: Quiet operation in cleanroom-adjacent and controlled production environments — where low noise, filtered airflow and low maintenance are required. - Quality control & pre-coating inspection: Make sure parts are static-free across their full width before coating, labelling, packaging or final inspection. Industries: Electronics & ESD-sensitive manufacturing; Optics, photonics & precision assembly; Automotive (headlights, interior plastics); Plastic injection moulding & finishing; Medical devices & cleanroom manufacturing; Printing & packaging (inspection and labelling stations); Semiconductors & flat panel display production. ### Complete system - SE-BLL blower (select length): SE-BLL-F-530-C / -700-C / -1055-C / -1420-C / -2130-C - SE-PSU-24-C-M12 power supply: 220 V AC to 24 V DC adapter — required · sold separately - 4-pin M12 cable: Industrial M12 connection cable — length to suit installation · sold separately - Foam filter (optional): Replaceable 10 PPI foam filter — orderable as accessory - Replacement ionizer module: Spare ionizer assembly — contact FÖGE for the part code - Maintenance kit (optional): FÖGE Antistatic Maintenance Kit — cleaning fluid and brush ### FAQ Q: Does the SE-BLL require an external high-voltage power unit? A: No. The SE-BLL operates at 24 V DC and contains its own pulsed DC ionization circuit. The SE-PSU-24-C-M12 power supply (220 V AC to 24 V DC) is required and sold separately. Q: What is the ionization range? A: Up to 1000 mm. The SE-BLL neutralises a surface from 1 kV down to 100 V in less than 7 seconds at 1000 mm distance — twice the 500 mm range of the SE-BLC-F-75-C compact blower. Q: What is the replaceable ionizer module? A: The ionizer module is the assembly that contains the high-voltage ionization circuit and the emitter pins. When it reaches end of life, only the module is exchanged — housing, fans and mounting bracket stay in service. Contact FÖGE for the replacement module part code. Q: Which length should I order? A: The ionized air outlet should span at least the full width of the work area or material to be neutralised. If the required width falls between two lengths, select the next length up. Q: How is the fan speed adjusted? A: With the ▲ / ▼ buttons on the front control panel. Higher fan speed is recommended for longer working distances, lower fan speed for close-range or delicate applications. Q: Is compressed air required? A: No. The SE-BLL uses its own built-in fans. Only a 24 V DC connection via the SE-PSU-24-C-M12 adapter is needed. Q: Which cable do I need? A: A 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable. Q: Is the blower suitable for cleanroom use? A: The SE-BLL suits cleanroom-adjacent and controlled-environment workstations thanks to its quiet operation, foam filter and laminar airflow. For certified cleanroom classifications, contact FÖGE to confirm suitability. Q: How are the emitter pins cleaned? A: Remove the front cover and clean the tungsten pins with the brush from the FÖGE Antistatic Products Maintenance Kit, then refit the cover. Clean the foam filters with a brush, compressed air or water. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-bll-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-bll-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-bll-dimensional-drawing-en.pdf ### 3D applications - Battery conveyor with SE-BLL: https://foge-antistatic.com/applications/battery-conveyor-se-bll/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-battery-conveyor-se-bll-application-sheet-en.pdf) - TV panel conveyor with SE-BLL: https://foge-antistatic.com/applications/tv-panel-conveyor-se-bll/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-tv-panel-conveyor-se-bll-application-sheet-en.pdf) ## SE-SGB-30 Static Generation Bar – 30 kV URL: https://foge-antistatic.com/products/static-electricity/static-charging/se-sgb-30/ Category: Static charging · Family: Charging bars 30 kV DC controlled electrostatic charging for precise film and foil pinning — wood lamination, film wrapping, solar panel production and more. The FÖGE SE-SGB-30 is a high-voltage DC static generation bar with a fundamentally different purpose from other FÖGE products: rather than eliminating static charge, it deliberately deposits a controlled electrostatic charge onto non-conductive materials such as films, foils and sheet substrates. Operating at up to 30 kV DC — supplied by the FÖGE SE-GEN-30N-AC high-voltage generator — the SE-SGB-30 generates a uniform electrostatic field along its full length. The result is a controlled electrostatic attraction between the charged film and the grounded substrate beneath it, which holds the film precisely in position — a technique known as electrostatic pinning. The SE-SGB-30 uses stay-sharp alloy emitters at 15 mm pitch, each protected by an integrated resistor, housed in a fully encapsulated, compact industrial body with a shockless, spark-free design. The uniform field ensures consistent pinning force across the full material width — preventing film drift, misalignment, wrinkling and positional errors during lamination, wrapping, cutting and pressing. The pinning effect is temporary and fully reversible: the charge dissipates once the film leaves the field, leaving no adhesive residue and requiring no mechanical release. ### Key features - Up to 30 kV DC output — controlled electrostatic field for reliable pinning - Electrostatic pinning — holds films, foils and sheet materials in precise position - Uniform field generation — consistent pinning force across the full material width - Stay-sharp alloy emitters at 15 mm pitch — resistively coupled for spark-free operation - Fully encapsulated compact design — shockless, spark-free - Temporary and reversible — no adhesive residue, no mechanical release required - No compressed air required — purely electrostatic - Compatible with the SE-GEN-30N-AC generator - Available in multiple lengths — contact FÖGE for options ### How it works The SE-SGB-30 connects to the SE-GEN-30N-AC high-voltage DC generator, which supplies up to 30 kV DC to the bar's stay-sharp alloy emitters. The high voltage ionizes the air around each pin, generating ions of predominantly one polarity — unlike an antistatic bar, which generates balanced positive and negative ions. These unipolar ions are deposited onto the surface of the non-conductive film as it passes beneath the bar, building up a controlled surface charge. The charged film is then strongly attracted towards the grounded surface beneath it — typically the wood panel, laminating table, substrate or roller. This force holds the film flat and in position, and it increases with the applied voltage. The encapsulated bar body and shockless circuit ensure that the field is directed towards the material, not the operator. ### What is electrostatic pinning? Electrostatic pinning is the controlled use of static charge to hold a non-conductive film, foil or sheet firmly against a substrate — without clamps, adhesive, vacuum or any physical fastening. The energised bar deposits a uniform DC charge onto the upper surface of the film. This creates an attraction between the film and the grounded surface beneath it, pressing the film flat and holding it in position during pressing, cutting, laminating or wrapping. When the film is released from the process, the charge dissipates and it can be removed without residue. The SE-SGB-30 uses static electricity as a process tool rather than treating it as a problem. ### Safety notes WARNING: HIGH VOLTAGE — 30 kV DC. Installation, commissioning, maintenance and servicing of the SE-SGB-30 and SE-GEN-30N-AC must be carried out by qualified electrical personnel only. - Shockless and spark-free design: when correctly installed and operated within its rated parameters, the bar does not produce operator shocks or dangerous sparks. The 30 kV operating voltage is hazardous if the equipment is damaged, incorrectly installed or modified. - Earthing requirement: the substrate or support structure beneath the film must be correctly earthed before operation. Incorrect earthing prevents the pinning effect and may create safety hazards. - Not for use near flammable materials: do not operate in the presence of flammable gases, vapours or dust. - Always read and follow the complete safety instructions in the SE-SGB-30 and SE-GEN-30N-AC installation and operation manual before use. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-SGB-30-xxxx-C2 (xxxx = length in mm) | | Function | Electrostatic charging — generates and deposits controlled static charge onto materials (not a static elimination product) | | Output voltage | Up to 30 kV DC — shockless | | Polarity | None — the bar can be connected to a positive or a negative generator | | Required generator | SE-GEN-30N-AC (FÖGE 30 kV DC generator — sold separately, required) | | Connector | High-voltage (HV) connector · generator connector set FG-AC-0049 | | Emitter type | Stay-sharp alloy emitters at 15 mm pitch, each individually protected by an integrated resistor | | Emitter layout | Dual-row emitter design | | Design | Fully encapsulated — shockless, spark-free, industrial-grade | | Construction | Extruded PVC body with ABS end caps, fully encapsulated with epoxy resin | | Dimensions | Profile 22.6 × 41 mm (W × H); active length = overall length − 90 mm | | Cable | 2 m HV cable with protective nylon conduit (longer on request); minimum bend diameter 100 mm | | Bars per generator | Up to 4 | | Safety resistance | 100 MΩ resistance for safe operation | | Environment | Clean, dry and oil-free; 0 – 60 °C; max. 70 % rH | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | | Charging effect | Uniform electrostatic field — deposits charge evenly across the material width | | Application | Electrostatic pinning of films, foils and sheet materials | | Ordering length | 100 – 4000 mm | Pinning force depends on applied voltage, material properties, substrate conductivity and environmental conditions. ### Applications - Wood industry — foil lamination: Decorative foil or melamine film must be held precisely on a wood panel or MDF board before the lamination press closes. The SE-SGB-30 pins the foil flat and aligned across the full width — eliminating mis-registration and wrinkling without clamps that would mark the foil. - Film & flexible packaging — wrapping: In shrink-wrapping, stretch-wrapping and overwrapping, pinning holds the film in contact with the product, preventing lifting, shifting or creasing before sealing or the heat tunnel. - Solar panel production — encapsulant & backsheet: EVA encapsulant and backsheet films are pinned to the substrate immediately after laying and held in position until the laminator closes — preventing cell misalignment, air entrapment and delamination. - Printing & converting — substrate pinning: Flexible substrates are held flat on the print bed or die-cut station — preventing edge lift and shifting, improving registration and reducing waste. - Thermoforming & laminating — sheet positioning: Film or sheet is held flat over the mould or substrate until the press closes — removing the need for positioning frames and clamp marks. - Automotive & technical films: Protective, masking and technical films are held in exact position during application and pressing on panels, glass and composites. Industries: Wood & furniture (foil lamination on MDF, particleboard and solid wood); Solar panel manufacturing; Film & flexible packaging; Printing & converting; Thermoforming & laminating; Automotive (protective and masking film application); Technical film & tape. ### Complete system - SE-SGB-30 bar (specify length): Static generation bar — should span the full width of the material to be pinned - SE-GEN-30N-AC generator: FÖGE 30 kV DC high-voltage generator — required · sold separately - HV connection cable: Connects the generator to the bar — specify required length - Earthing of substrate: The table, roller or panel beneath the film must be earthed — consult FÖGE for requirements - Mounting brackets: Position the bar at the correct height above the material — contact FÖGE for options ### FAQ Q: What is electrostatic pinning and how is it different from static elimination? A: Static elimination removes unwanted charge to prevent dust attraction, shocks and process defects. Electrostatic pinning deliberately applies a controlled charge to a non-conductive film so that it is attracted to the substrate beneath and held in position. The SE-SGB-30 is the only FÖGE product that generates charge; all others remove it. Q: Does electrostatic pinning leave any residue? A: No. Pinning uses only electric charge — no adhesive, coating or physical contact with the film. When the field is removed, the charge dissipates and the film releases cleanly. Q: What generator does the SE-SGB-30 require? A: The FÖGE SE-GEN-30N-AC 30 kV DC high-voltage generator, sold separately. Do not use the SE-SGB-30 with any other power source. Q: Does the substrate need to be earthed? A: Yes. Pinning works by attraction between the charged film and the substrate beneath it, so the table, roller, panel or support frame must be correctly earthed. Consult FÖGE for the requirements of your application. Q: Is electrostatic pinning suitable for all film types? A: It works on non-conductive materials — most plastic films (PE, PP, PET, PVC, EVA), decorative foils, paper-based films and most flexible packaging. It is not effective on conductive materials. Contact FÖGE to confirm suitability for your material. Q: How strong is the pinning force? A: It depends on the applied voltage, the dielectric properties and thickness of the film, and the distance between bar and substrate. At 30 kV, the SE-SGB-30 holds films against gravity and process air currents in most industrial applications. Contact FÖGE for a force estimate. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-sgb-30-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-sgb-30-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-sgb-30-dimensional-drawing-en.pdf ### 3D applications - Wrapping with SE-SGB-30 pinning: https://foge-antistatic.com/applications/wrapping-pinning-se-sgb-30/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-wrapping-pinning-se-sgb-30-application-sheet-en.pdf) - Wood foil pinning with SE-SGB-30: https://foge-antistatic.com/applications/wood-foil-pinning-se-sgb-30/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-wood-foil-pinning-se-sgb-30-application-sheet-en.pdf) ## SE-ACG Antistatic Airgun URL: https://foge-antistatic.com/products/static-electricity/dust-removal-cleaning/se-acg/ Category: Dust removal & cleaning · Family: Antistatic airguns High-efficiency static elimination and dust removal for surface cleaning before painting, coating and assembly. The FÖGE SE-ACG is a high-performance antistatic airgun designed for precision dust removal and static charge neutralisation on non-conductive surfaces such as plastics, glass, film and painted parts. Used immediately before critical finishing operations — painting, coating, glazing, inspection or assembly — it prevents the quality failures and production interruptions caused by electrostatically attracted dust and particles. Unlike standard compressed-air guns that simply blow dust around, the SE-ACG combines ionized air with strong, targeted airflow. The ionized air breaks the electrostatic bond between dust and surface, allowing the airflow to fully remove the contaminants rather than redistributing them. Its 7 asymmetric tungsten ionizing pins deliver ESD-compliant ionization up to 600 mm away, while the shockless design and ergonomic housing ensure safe, comfortable operation throughout the working day. Available in a standard nozzle version and an optional silent nozzle version (77 dB) for noise-sensitive environments. ### Key features - Integrated ionizer — combines static elimination and dust removal in one compact tool, no separate ionization bar required - 7 asymmetric tungsten ionizing pins — ESD compliant, high ionization power, extremely long service life - 5.5 kV AC shockless ionization — operator-safe at all times - Ionization range up to 600 mm — effective across a wide working distance - Ergonomic and robust design — lightweight, comfortable for extended manual operation - Optional silent nozzle — reduces noise to 77 dB at 30 cm for operator comfort - Targeted airflow — breaks the electrostatic bond to fully remove, not redistribute, dust - Compatible with SE-PAC-55 power units (2-output or 4-output) - Three cable length options: 3 m (C3), 5 m (C5), 12 m (C12) - Industrial-grade, impact-resistant housing ### How it works The SE-ACG is connected via its HV cable to an SE-PAC-55 AC power unit, which supplies 5.5 kV to the gun's 7 asymmetric tungsten ionizing pins. When compressed air flows through the gun, it passes over these energised pins and becomes ionized — generating a balanced stream of positive and negative ions. When this ionized airflow is directed at a charged surface, the ions neutralise the electrostatic charge that is holding dust and particles in place. Once the bond is broken, the continuing airflow carries the particles away from the surface. The result is a surface that is both static-free and physically clean. The shockless circuit design limits pin current to a safe level at all times, regardless of operating distance. ### Variants — standard nozzle vs silent nozzle Both variants deliver the same ionization performance — the difference is air consumption and noise level. | Parameter | SE-ACG-55-SN (standard nozzle) | SE-ACG-55-LN (silent nozzle) | |---|---|---| | Product code | SE-ACG-55-SN-C3 | SE-ACG-55-LN-C3 | | Noise level | Standard | 77 dB at 30 cm distance | | Air consumption @ 3 bar | 230 l/min | 130 l/min | | Air consumption @ 5 bar | 260 l/min | 170 l/min | | Cable (standard) | C3 — 3 m HFFR-protected flex with HV connector | C3 — 3 m HFFR-protected flex with HV connector | | Cable options | C5 (5 m) · C12 (12 m) | C5 (5 m) · C12 (12 m) | | Best for | Maximum cleaning power, standard noise environments | Noise-sensitive workstations, operator comfort priority | ### Technical specifications | Parameter | Specification | |---|---| | Variants | SE-ACG-55-SN-C3 (standard nozzle) · SE-ACG-55-LN-C3 (silent nozzle) | | Compatible power unit | SE-PAC-55-2-C (2 outputs) · SE-PAC-55-4-C (4 outputs) | | Ionization type | 5.5 kV AC — shockless — ESD compliant | | Ionizing pin type | 7 asymmetric tungsten pins — ESD compliant, high ionization power, extremely long lifetime | | Pin current (safety) | < 250 μA; transformer current max. 5 mA (fused) | | Polarity | Alternating AC | | Ionization range | Up to 600 mm * (depending on environment and air conditions) | | Air connection | ⌀ 8 mm hose — straight fitting | | Air pressure | Up to 5 bar — dry, filtered air required | | Operating temperature | Max. 60 °C | | Max. humidity | 70 % rH, non-condensing | | Protection class | IP66 — fully sealed | | Housing | Industrial-grade, impact-resistant | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | * Static charge on surface reduced to below ±35 V, tested at 300 mm distance with 5 bar air pressure. ### Applications - Pre-paint & pre-coat surface cleaning: Remove static and dust from plastic body panels, automotive trim and industrial components immediately before painting or powder coating — eliminating dust inclusions and fish-eye defects. - Injection moulding post-demould cleaning: Neutralise and clean moulded plastic parts as they leave the press — removing mould-release residue, particles and static charge before the next process step. - Glass and optical surface cleaning: Clean glass panels, lenses and optical components before glazing, coating or inspection — preventing scratches and contamination from statically attracted particles. - Electronics & PCB handling: Remove flux residue, solder particles and dust from PCBs and electronic components at assembly or rework stations — preventing ESD damage and short circuits. - Machined & cut parts cleaning: Clean metal or plastic parts after milling, drilling or cutting operations — removing chips, swarf and particles before surface treatment or assembly. - Pre-assembly inspection cleaning: Prepare parts for visual or automated inspection by ensuring surfaces are free of dust and static — reducing false rejects and improving inspection accuracy. - Whitegoods & appliance manufacturing: Clean plastic enclosures, panels and components before assembly — preventing cosmetic defects caused by dust trapped under surface finishes. Industries: Automotive (body panels, interior trim, pre-paint preparation); Plastics & injection moulding; Electronics & semiconductor manufacturing; Whitegoods & consumer appliances; Glass & optical industries; General manufacturing (machining, assembly, inspection); Printing & packaging (pre-print surface preparation). ### Complete system - SE-ACG-55-SN-C3: Antistatic airgun with standard nozzle — 3 m cable (C5/C12 options available) - SE-ACG-55-LN-C3: Antistatic airgun with silent nozzle — 3 m cable (C5/C12 options available) - SE-PAC-55-2-C power unit: 2-output AC high-voltage power unit — required to operate the SE-ACG - SE-PAC-55-4-C power unit: 4-output AC high-voltage power unit — powers up to 4 units simultaneously - Compressed air supply: Dry, filtered compressed air — ⌀ 8 mm hose, up to 5 bar - Maintenance kit: FÖGE Antistatic Maintenance Kit — cleaning tools and spare tungsten pins ### FAQ Q: What is the difference between the SE-ACG and a standard compressed-air gun? A: A standard compressed-air gun only blows air — it cannot neutralise static charges, so electrostatically attracted dust is simply moved to another area rather than removed. The SE-ACG ionizes the air before it leaves the nozzle, neutralising the static bond between dust and surface first, then physically removing the particles. This produces a genuinely clean, static-free surface. Q: What power unit does the SE-ACG require? A: The SE-ACG requires an SE-PAC-55 external AC high-voltage power unit. It is available in SE-PAC-55-2-C (2 outputs) and SE-PAC-55-4-C (4 outputs) configurations. The power unit must be ordered separately. Q: What is the difference between the SN and LN nozzle variants? A: The SN (standard nozzle) variant delivers higher air volume — up to 230 l/min at 3 bar — the highest cleaning air volume of the nozzle variants. The LN (silent nozzle) variant reduces air consumption to 130 l/min at 3 bar and brings noise levels down to 77 dB at 30 cm, making it the preferred choice for workstations where operator noise exposure is a concern. Q: What cable lengths are available? A: The standard configuration comes with a 3 m cable (C3). Options for 5 m (C5) and 12 m (C12) cables are also available for installations where the power unit is mounted away from the workstation. Q: What type of compressed air is required? A: The SE-ACG requires dry, filtered compressed air supplied via a ⌀ 8 mm hose at up to 5 bar. Oil or moisture in the air supply will reduce ionization efficiency and may damage the emitter pins. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-acg-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-acg-manual-en.pdf - Dimensional drawing SE-ACG-55-SN-C3: https://foge-antistatic.com/downloads/drawings/foge-se-acg-55-sn-c3-dimensional-drawing-en.pdf - Dimensional drawing SE-ACG-55-LN-C3: https://foge-antistatic.com/downloads/drawings/foge-se-acg-55-ln-c3-dimensional-drawing-en.pdf ### 3D applications - Headlight lens cleaning with SE-ACG: https://foge-antistatic.com/applications/headlight-cleaning-se-acg/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-headlight-cleaning-se-acg-application-sheet-en.pdf) - Headlight housing station with SE-ACG + SE-BLC: https://foge-antistatic.com/applications/headlight-housing-assembly-se-acg-blc/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-headlight-housing-assembly-se-acg-blc-application-sheet-en.pdf) - Manual cleaning station with SE-ACG: https://foge-antistatic.com/applications/manual-cleaning-station-se-acg/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-manual-cleaning-station-se-acg-application-sheet-en.pdf) - Flat panel cleaning with SE-ACG: https://foge-antistatic.com/applications/flat-panel-cleaning-se-acg/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-flat-panel-cleaning-se-acg-application-sheet-en.pdf) ## SE-ACS-55-50 Compact Antistatic Spot Nozzle URL: https://foge-antistatic.com/products/static-electricity/dust-removal-cleaning/se-acs-55-50/ Category: Dust removal & cleaning · Family: Spot nozzles High-precision ionization for targeted dust removal in corners, cavities and hard-to-reach spot areas. The FÖGE SE-ACS-55-50 is a compact, self-contained AC spot ionizing nozzle designed for precision dust removal and static charge neutralisation in targeted, small-area applications. Where wide-area ionization bars cover an entire surface and inline components require machine integration, the SE-ACS-55-50 delivers focused, high-intensity ionized airflow through its ⌀ 3 mm nozzle directly onto corners, edges, cavities, stacked layers and other hard-to-reach spots where conventional cleaning tools fail to dislodge electrostatically bound particles. Powered by an SE-PAC-55 AC high-voltage power unit, the SE-ACS-55-50 generates ionized air using 7 asymmetric tungsten ionizing pins — chosen for their ESD compliance, extremely long service life and high ionization efficiency. It can be used standalone in a fixed installation, paired with a separate airgun system for flexible spot cleaning, or mounted on automated equipment. With an ionization range of up to 300 mm, air pressure between 4 and 8 bar, and three cable length options, the SE-ACS-55-50 adapts to a wide range of cleaning setups. ### Key features - Compact self-contained spot ionizing nozzle — complete, ready-to-use unit with integrated ionizer - 7 asymmetric tungsten ionizing pins — ESD compliant, high ionization output, extremely long service life - 5.5 kV AC shockless ionization — operator-safe and ESD-safe for sensitive components - ⌀ 3 mm nozzle outlet — concentrates ionized airflow into a precise spot - Ionization range up to 300 mm - Air pressure range 4 – 8 bar — adaptable to different cleaning intensities - Exchangeable nozzle options — tailor airflow geometry to the cleaning application - Can be used standalone, combined with an airgun system, or mounted on automated equipment - Washable, industrial-grade housing — easy to maintain in dusty environments - Shockless design — safe for operators and sensitive electronics nearby - Three cable lengths: 3 m (C3), 5 m (C5), 12 m (C12) - Up to 4 units per SE-PAC-55 power unit ### How it works The SE-ACS-55-50 is connected via its HV cable to an SE-PAC-55 AC power unit, which energises the 7 asymmetric tungsten ionizing pins inside the unit at 5.5 kV. Compressed air at 4 – 8 bar flows through the body, passes over the energised pins, and exits as a concentrated stream of ionized air through the ⌀ 3 mm nozzle tip. When this ionized airflow reaches the target surface, the balanced positive and negative ions neutralise the electrostatic charge that bonds dust particles to the surface. Once the bond is broken, the continuing airflow physically carries the particles away from the spot. The shockless circuit design ensures that the pin current remains at a safe level at all times, regardless of operating distance. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-ACS-55-50-50 | | Compatible power unit | SE-PAC-55-2-C (2 outputs) · SE-PAC-55-4-C (4 outputs) | | Ionization type | 5.5 kV AC — shockless | | Pin current (safety) | < 250 μA; transformer current max. 5 mA (fused) | | Ionizing pin type | 7 asymmetric tungsten pins — ESD compliant, high ionization power, extremely long lifetime | | Nozzle outlet diameter | ⌀ 3 mm | | Air connection | ⌀ 8 mm hose — straight fitting | | Air pressure | 4 – 8 bar — dry, filtered air required | | Air consumption | 250 l/min at 4 bar · 280 l/min at 6 bar | | Air flow speed | 18 m/s at 4 bar · 20 m/s at 6 bar (measured at 30 cm) | | Ionization range | Up to 300 mm * | | Polarity | Alternating AC | | Noise level | 85 – 90 dB at 1000 mm | | Operating temperature | Max. 60 °C | | Max. humidity | 70 % rH, non-condensing | | Protection class | IP66 | | Housing | Washable, fully sealed | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | | Cable — C3 (standard) | 3 m HFFR-protected flex cable with HV connector | | Cable — C5 (option) | 5 m HFFR-protected flex cable with HV connector | | Cable — C12 (option) | 12 m HFFR-protected flex cable with HV connector | | Units per power unit | Up to 4 per SE-PAC-55 power unit | * Static charge reduced to below ±35 V, tested at 300 mm distance with 5 bar air pressure. ### Applications - Bottle caps & container openings: Remove static and dust from the inside of bottle caps, vial tops and container openings before filling or sealing — preventing contamination of contents. - Optical lenses & headlight covers: Clean lenses, glass panels and headlight cover lenses before assembly, glazing or coating — eliminating particle inclusions that cause optical defects. - Stacked plastic films or plates: Neutralise static between layers of stacked film or sheet — enabling clean separation and preventing layer-to-layer adhesion and misalignment. - Corners, holes & narrow part geometry: Deliver ionized airflow precisely into recessed corners, drilled holes and narrow slots where conventional nozzles and bars cannot direct the airflow effectively. - Printing lines & digital printers: Clean small substrate areas before printing — removing particles that would cause ink smearing, dot gain or print head contamination. - Packaging — box & tray interior: Remove dust and static from the inside surfaces of packaging boxes, trays and inserts before product placement or sealing. - Pre-inspection cleaning stations: Prepare parts for visual or automated inspection — ensuring surface cleanliness to reduce false rejects and improve inspection accuracy. - Automated cleaning on fixed equipment: Mount on automated cleaning stations, conveyors or in-line fixtures for hands-free spot ionization at a fixed point in the production flow. Industries: Food & beverage (bottle, cap and container filling lines); Automotive (optics, lighting, precision plastic components); Pharmaceuticals & medical devices; Printing & packaging; Electronics & semiconductor (ESD-safe component cleaning); Wood & furniture (surface preparation before painting); Plastics & injection moulding; General manufacturing (inspection and assembly preparation). ### Complete system - SE-ACS-55-50-50: Compact antistatic spot nozzle — 3 m cable (C5 / C12 also available) - SE-PAC-55-2-C power unit: 2-output AC high-voltage power unit — required to operate the SE-ACS-55-50 - SE-PAC-55-4-C power unit: 4-output AC high-voltage power unit — powers up to 4 SE-ACS-55-50 units - Compressed air supply: Dry, filtered compressed air — ⌀ 8 mm hose, 4 – 8 bar - Exchangeable nozzle tips: Optional alternative nozzle geometries — contact FÖGE for available options - Maintenance kit: FÖGE Antistatic Maintenance Kit — replacement tungsten pins and cleaning tools ### FAQ Q: What is the difference between the SE-ACS-55-50 and the SE-ACIN-55? A: The SE-ACIN-55 is an inline OEM component designed to be permanently built into machines, cleaning boxes and custom systems — it has no fixed nozzle geometry and is not a self-contained device. The SE-ACS-55-50 is a complete, self-contained spot nozzle unit — it can be used in a fixed installation, combined with a separate airgun or mounted on automated equipment without custom integration work. Q: What is the difference between the SE-ACS-55-50 and the SE-ACG airgun? A: The SE-ACG is a handheld tool operated manually at a workstation. The SE-ACS-55-50 is a fixed or semi-fixed spot nozzle mounted in a defined position — at a cleaning station, on a conveyor fixture or on automated equipment. It is not designed as a handheld operator tool. Q: What power unit does the SE-ACS-55-50 require? A: The SE-ACS-55-50 requires an SE-PAC-55 external AC high-voltage power unit, available as SE-PAC-55-2-C (2 outputs) and SE-PAC-55-4-C (4 outputs). Up to 4 units per power supply. Ordered separately. Q: Can the nozzle tip be changed? A: Yes. The SE-ACS-55-50 supports exchangeable nozzle tips to adapt the airflow geometry to different cleaning applications. Contact FÖGE for available nozzle options. Q: What air pressure is needed? A: The SE-ACS-55-50 operates with dry, filtered compressed air between 4 and 8 bar. Lower pressure (4 bar) is suitable for delicate surfaces; higher pressure (up to 8 bar) delivers greater cleaning force for more robust applications. Q: What cable lengths are available? A: Three options: C3 (3 m standard), C5 (5 m) and C12 (12 m). The C12 option is useful for installations where the SE-PAC-55 power unit is located at a distance from the nozzle. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-acs-55-50-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-acs-55-50-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-acs-55-50-dimensional-drawing-en.pdf ## SE-ACIN-55 AC Inline Air Ionizer URL: https://foge-antistatic.com/products/static-electricity/dust-removal-cleaning/se-acin-55/ Category: Dust removal & cleaning · Family: Inline ionizers Compact spot ionization for integration into dust cleaning machines, custom airguns and automated systems. The FÖGE SE-ACIN-55 is a compact, high-efficiency inline ionizing unit designed to deliver focused spot static elimination and dust removal in embedded or machine-integrated applications. Unlike standalone airguns or wide-area ionization bars, the SE-ACIN-55 is built to be integrated directly inside dust cleaning boxes, custom-built airguns, enclosed cleaning stations and OEM equipment — providing targeted ionized airflow precisely where contamination control is needed. Operating at 5.5 kV AC with a shockless circuit, it combines compressed air with ionization to break the electrostatic bond holding dust particles onto non-conductive surfaces, then removes them with the outgoing airflow. Available in two variants: the NN (no nozzle) version with an adjustable-length replaceable emitter needle for tight cavities and custom OEM integration, and the SN (spot nozzle) version with a fixed point nozzle for defined-area spot cleaning up to 300 mm. Compatible with SE-PAC-55 power units and available with 3 m, 5 m or 12 m cables. ### Key features - Compact inline design — integrates directly into enclosures, cleaning boxes and custom machine builds - 5.5 kV AC shockless ionization — operator-safe and suitable for sensitive equipment environments - Two variants: NN (no nozzle, adjustable needle) and SN (fixed spot nozzle) - Focused spot ionization — delivers ionized air precisely where it is needed - Replaceable, adjustable-length emitter pin (NN) — reaches deep cavities, part stacks or narrow tooling - Ionization range up to 300 mm (SN variant) - Compatible with multiple nozzle configurations — spot cleaning, air knives, custom channels - Nozzle-free option (NN) for OEM integrators designing custom airflow paths - Shockless operation — safe for use near sensitive electronics and precision components - Three cable length options: 3 m (C3), 5 m (C5), 12 m (C12) - Up to 4 units per SE-PAC-55 power unit ### How it works The SE-ACIN-55 is connected via its HV cable to an SE-PAC-55 AC power unit, which energises the internal emitter pin at 5.5 kV. When compressed air at 6 bar flows through the inline body, it passes over the energised pin and becomes ionized — producing a concentrated stream of balanced positive and negative ions. In the SN variant, this ionized airflow exits through the fixed spot nozzle onto the target surface up to 300 mm away. In the NN variant, the airflow exits through the adjustable needle tip, directed precisely into a cavity or custom channel. The ions neutralise the static charge holding dust particles in place; the continuing airflow carries them away. The shockless circuit keeps pin current at a safe level at all times. ### Variants — NN (no nozzle) vs SN (spot nozzle) Both variants share the same 5.5 kV AC ionization technology — the difference is the airflow delivery method and integration geometry. | Parameter | SE-ACIN-55-NN (no nozzle) | SE-ACIN-55-SN (spot nozzle) | |---|---|---| | Product code | SE-ACIN-55-NN-C3 | SE-ACIN-55-SN-C3 | | Nozzle | No nozzle — adjustable-length emitter needle | Fixed point / spot nozzle | | Ionization range | Depends on application & needle length | Up to 300 mm * | | Air consumption | Depends on application | 320 l/min at 6 bar | | Weight | 315 g | 364 g | | Emitter pin | Replaceable — adjustable for deep cavities | Fixed — optimised for spot cleaning | | Integration type | OEM / custom build — no fixed nozzle geometry | Defined spot area — fixed outlet geometry | | Best for | Machine builders, custom cavities, OEM equipment | Spot cleaning at a defined point, up to 300 mm | * Static charge reduced to below ±35 V, tested at 300 mm with 5 bar air pressure. ### Technical specifications | Parameter | Specification | |---|---| | Variants | SE-ACIN-55-NN-C3 (no nozzle) · SE-ACIN-55-SN-C3 (spot nozzle) | | Compatible power unit | SE-PAC-55-2-C (2 outputs) · SE-PAC-55-4-C (4 outputs) | | Ionization type | 5.5 kV AC — shockless | | Pin current (safety) | < 250 μA; transformer current max. 5 mA (fused) | | Polarity | Alternating AC | | Air connection | ⌀ 8 mm hose — straight fitting | | Air pressure | 6 bar inlet — clean, dry, oil-free filtered air | | Air flow speed | 14 m/s at 300 mm (SN variant) | | Noise level | 83 dB at 1000 mm | | Operating temperature | 0 – 50 °C | | Max. humidity | 70 % rH, non-condensing | | Housing | Industrial-grade, impact-resistant | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | | Cable — C3 (standard) | 3 m HFFR-protected flex cable with HV connector | | Cable — C5 (option) | 5 m HFFR-protected flex cable with HV connector | | Cable — C12 (option) | 12 m HFFR-protected flex cable with HV connector | | Units per power unit | Up to 4 units per SE-PAC-55 power unit | Variant-specific values (ionization range, air consumption, weight) are listed in the variant table above. ### Applications - Dust cleaning boxes: Integrated inside enclosed cleaning chambers — delivers ionized airflow to neutralise static and remove dust from parts before further processing. - Custom OEM airguns & nozzles: Built into airgun bodies and nozzle assemblies designed by machine builders and integrators — provides the ionization function without a separate ionizer unit. - Robotic end-of-arm tools: Mounted on robotic end-effectors — delivers targeted ionized air to a specific area of a part during pick-and-place, handling or pre-inspection routines. - Film & paper web processing: Mounted at static-critical points in web feed systems — neutralises charges at specific locations where material accumulates static most heavily. - Optics & headlight assembly: Used inside enclosed cleaning stations for lenses, reflectors and optical components — removes particles before assembly or glazing. - Bottle & cap cleaning lines: Integrated into inline cleaning stations on filling lines — removes static and loose particles from containers before filling or capping. - Printing & packaging equipment: Built into narrow machine frames or print head housings — neutralises static on substrates at precisely the right point before printing or sealing. - Electronics & PCB handling: Integrated into component handling or conveyor stations — safely removes static and dust from boards and assemblies without risk of ESD damage. Industries: OEM machine builders & system integrators; Automotive (precision component cleaning, optics, headlights); Electronics & semiconductor manufacturing; Plastics & injection moulding; Food & beverage (bottle and container lines); Printing & packaging; Optical & lighting industries; Wood & furniture (surface preparation before coating). ### Complete system - SE-ACIN-55-NN-C3: No-nozzle variant with adjustable emitter needle — 3 m cable (C5 / C12 also available) - SE-ACIN-55-SN-C3: Spot nozzle variant with fixed point nozzle — 3 m cable (C5 / C12 also available) - SE-PAC-55-2-C power unit: 2-output AC high-voltage power unit — required to operate the SE-ACIN-55 - SE-PAC-55-4-C power unit: 4-output AC high-voltage power unit — powers up to 4 SE-ACIN-55 units - Compressed air supply: Dry, filtered compressed air — ⌀ 8 mm hose, 6 bar - Maintenance kit: FÖGE Antistatic Maintenance Kit — replacement emitter pins and cleaning tools ### FAQ Q: What is the difference between the SE-ACIN-55 and the SE-ACG airgun? A: The SE-ACG is a handheld tool operated manually at a workstation. The SE-ACIN-55 is an inline component built permanently into machines, cleaning boxes and OEM equipment — it is not a handheld device. The SE-ACIN-55 provides focused spot ionization at a fixed point within a machine, while the SE-ACG is used for flexible hand-directed surface cleaning. Q: What is the difference between the NN and SN variants? A: The NN (no nozzle) variant has an adjustable-length replaceable emitter needle with no fixed nozzle geometry — ideal for OEM integration into custom cavities, tooling and machine channels where the airflow path is defined by the surrounding structure. The SN (spot nozzle) variant has a fixed point nozzle that concentrates ionized airflow onto a defined spot area up to 300 mm away — suited for defined-area spot cleaning in open or semi-enclosed spaces. Q: What power unit does the SE-ACIN-55 require? A: The SE-ACIN-55 requires an SE-PAC-55 external AC high-voltage power unit, available as SE-PAC-55-2-C (2 outputs) and SE-PAC-55-4-C (4 outputs). Up to 4 units can run from a single power unit. Ordered separately. Q: Can the emitter pin length be customised on the NN variant? A: Yes. The emitter needle on the NN variant is replaceable and the length can be specified to match the integration geometry — ideal for deep cavities, enclosed tooling and custom nozzle designs. Contact FÖGE to specify the required pin length. Q: What cable lengths are available? A: Three options: C3 (3 m standard), C5 (5 m) and C12 (12 m). The 12 m cable is useful when the SE-PAC-55 power unit is mounted at a distance from the inline integration point inside the machine. Q: Can multiple units be connected to one power unit? A: Yes. Up to 4 SE-ACIN-55 units can be connected to a single SE-PAC-55 power unit — cost-effective for machines with multiple ionization points. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-acin-55-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-acin-55-manual-en.pdf - Dimensional drawing SE-ACIN-55-SN-C3: https://foge-antistatic.com/downloads/drawings/foge-se-acin-55-sn-c3-dimensional-drawing-en.pdf - Dimensional drawing SE-ACIN-55-NN-C3: https://foge-antistatic.com/downloads/drawings/foge-se-acin-55-nn-c3-dimensional-drawing-en.pdf ## SE-HSIN-35-SN-C High Speed Air Ionizer — Standard Nozzle URL: https://foge-antistatic.com/products/static-electricity/dust-removal-cleaning/se-hsin/ Category: Dust removal & cleaning · Family: Inline ionizers Compact 24 V DC ionized-air nozzle for spot cleaning and static elimination in machines and automated systems. The SE-HSIN series antistatic air nozzle is designed for industrial environments where electrostatic charges and surface contamination must be controlled. It neutralises static electricity and removes dust, particles and other contaminants from target surfaces with ionized compressed air. The ionized airflow carries positive and negative ions to the target area, reducing the charges that attract contamination or disturb manufacturing processes. The concentrated airflow cleans and neutralises in localised and difficult-to-reach areas. The compact design suits space-constrained installations and integration into machinery and automated systems; the unit is powered with 24 V DC via an M12 connector. ### Key features - Compact design for space-constrained installations - Easy integration into machinery and automated systems - Long-life tungsten emitter - 24 V DC supply via M12 connector — 0.4 A, max. 9 W - Hose connection adapters from 100 to 300 mm - Adjustable slotted mounting bracket - Status LEDs: H.V, OK, status, power ### How it works Compressed air enters through the 6 mm air inlet with flow control valve and passes the tungsten emitter, where the ionizer generates positive and negative ions. The ionized air leaves through the nozzle and the hose connection adapter and is directed at the target surface, where it neutralises static charges and blows away the particles they were holding. ### Accessories | Ordering code | Accessory | |---|---| | FG-AC-0070 | Hose connection adapter 100 mm | | FG-AC-0071 | Hose connection adapter 150 mm | | FG-AC-0072 | Hose connection adapter 200 mm | | FG-AC-0073 | Hose connection adapter 250 mm | | FG-AC-0074 | Hose connection adapter 300 mm | | FG-AC-0075 | Mounting bracket | ### Electrical connection — M12 pin assignment | Pin | Function | |---|---| | 1 | +24 V DC (brown) | | 2 | Not used (white) | | 3 | 24 V − / GND (blue) | | 4 | Not used (black) | | 5 | Protective earth, PE (yellow/green) | Pin assignment as in the SE-HSIN-35-SN-C dimensional drawing. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-HSIN-35-SN-C (standard nozzle) | | Power supply | 24 V DC via M12 connector · 0.4 A · max. 9 W | | Air connection | 6 mm hose | | Air pressure — dry filtered air | 6 bar | | Inlet pressure | 6 bar | | Compressed air consumption | 320 L/min (changes with the nozzle attached) | | Air flow speed | 14 m/s (changes with the nozzle attached) | | Inline lance (nozzle tube) | Perforated tube on the hose connection adapter · 100 / 150 / 200 / 250 / 300 mm (FG-AC-0070 … FG-AC-0074) | | Noise level | 83 dB (changes with the nozzle attached) | | Cable | 4-pin M12 cable (sold separately) | | Power connector | M12, 5-pin male — use a 4-pin M12 cable | | Status LEDs | H.V · OK · Status · Power | | Emitter | Tungsten — long life | | Housing dimensions | 115.5 × 24 × 49.5 mm (without hose adapter) | | Environment | Clean, dry and oil-free · 0 – 50 °C · 70 % rH non-condensing max. | | Safety | Shockless, pin current < 250 μA · transformer current max. 5 mA (with fuse) | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | ### Applications - Electronics manufacturing: Clean and neutralise components and assemblies in localised areas. - Plastic processing: Remove dust from moulded parts before assembly or coating. - Packaging & printing: Neutralise and clean at specific points in packaging and printing machines. - Optical inspection systems: Keep inspection areas free of dust and static. Industries: Electronics manufacturing; Plastic processing; Packaging; Printing; Optical inspection. ### Complete system - SE-HSIN-35-SN-C ionizer: Standard nozzle version - 24 V DC power supply + 4-pin M12 cable: 24 V DC, 0.4 A, max. 9 W via the M12 connector - Compressed air supply: Dry, filtered air at 6 bar via 6 mm hose - Grounding cable: Connect to the grounding point on the front of the device ### FAQ Q: What does the SE-HSIN need to operate? A: A 24 V DC supply via the M12 connector (0.4 A, max. 9 W), dry filtered compressed air at 6 bar through a 6 mm hose, and a ground connection. Q: Which cable do I need? A: M12 cable (sold separately). Q: Why do air consumption, air speed and noise depend on the nozzle? A: The values change with the nozzle and hose connection adapter attached. The datasheet values are 320 L/min, 14 m/s and 83 dB. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-hsin-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-hsin-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-hsin-dimensional-drawing-en.pdf ### 3D applications - Transfer pipe with SE-HSIN: https://foge-antistatic.com/applications/transfer-pipe-se-hsin/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-transfer-pipe-se-hsin-application-sheet-en.pdf) - Granule hopper with SE-HSIN: https://foge-antistatic.com/applications/granule-hopper-se-hsin/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-granule-hopper-se-hsin-application-sheet-en.pdf) ## SE-ARN-80 Ionizing Ring – 8 kV URL: https://foge-antistatic.com/products/static-electricity/dust-removal-cleaning/se-arn-80/ Category: Dust removal & cleaning · Family: Ionizing rings 8 kV AC wide-area static elimination for complex 3D parts — ionizing ring only or complete rotating air nozzle system. The FÖGE SE-ARN-80 is a high-power 8 kV AC ionizing ring designed to neutralise static electricity across the full circumference of complex, three-dimensional parts such as plastic moulded components, automotive lenses, headlight covers and machined surfaces. Unlike flat ionization bars that treat one surface at a time, the ring design surrounds the part — delivering ionization from all sides simultaneously, including edges, curves and undercuts. It is designed primarily for robotic arm mounting, fixed automated cleaning stations and conveyor integration where parts pass through or rotate within the ionization field. The SE-ARN-80 is available in two variants. The AC01 is an ionizing ring only — it provides the ionization function without any air system, allowing machine builders and OEM integrators to combine it with their own nozzle, rotary air blower or cleaning mechanism. The PA is a complete, ready-to-use system that integrates the ionizing ring with a pulsed air rotating nozzle, providing both ionization and physical dust removal in a single self-contained unit. Both variants operate at 8 kV AC, use tungsten ionizing pins and are powered by the SE-PAC-80 power unit series. ### Key features - 8 kV AC shockless ionization — higher power than 5.5 kV systems for heavily charged parts and larger distances - Ring ionizer design — ionization wraps around the part, not just one face - Two variants: AC01 (ionizing ring only, customer's own air/nozzle system) and PA (integrated rotating nozzle + ionizing ring) - PA variant: integrated pulsed air rotating nozzle — adjustable blowing angle, stable rotation speed, coverage up to 300 mm - AC01 variant: no air — silent operation, for integration with existing air or rotary systems - Tungsten ionizing pins — extreme service life, minimal maintenance - Multiple heads synchronisable — cover large or complex parts with multiple cleaning heads - Designed for robotic arm mounting and fixed automated installations - Flexible mounting at various angles to suit different machine geometries - Three cable lengths: 3 m (C3), 5 m (C5), 12 m (C12) - Up to 4 units per SE-PAC-80 power unit ### How it works The SE-ARN-80 is connected via its HV cable to an SE-PAC-80 AC power unit, which supplies 8 kV to the tungsten ionizing pins arranged in a ring around the unit. The ring geometry creates an ionization field that extends inward across the full interior of the ring — so any part positioned within or passed through the ring is ionized from all sides simultaneously. In the AC01 variant, this ionization-only function is delivered without any airflow; the customer's own air or rotary system handles the physical particle removal. In the PA variant, pulsed compressed air at 4 – 8 bar drives a high-speed rotating nozzle that distributes ionized airflow across the part, detaching and carrying away dust and static-bound particles in a single automated cleaning cycle. The shockless circuit design keeps pin current within safe limits at all times. ### Variants — AC01 (ionizing ring only) vs PA (complete rotating nozzle) Choose the AC01 if you already have an air or rotary system and need only the ionization ring; choose the PA for a complete self-contained unit. | Parameter | SE-ARN-80-112-C3-AC01 | SE-ARN-80-112-C3-PA | |---|---|---| | Design | Ionizing ring only — customer integrates own nozzle or rotary air system | Ionizing ring + integrated pulsed air rotating nozzle | | Air connection | None — no air required | ⌀ 8 mm hose, straight fitting | | Air pressure | — | 4 – 8 bar — dry, filtered | | Air consumption | — | 180 l/min at 4 bar · 240 l/min at 6 bar | | Rotating nozzle | Not included | Integrated — adjustable blowing angle, stable rotation speed | | Ionization range | Up to 100 mm | Up to 300 mm * | | Noise level | Silent — no air | 73 – 83 dB at 30 cm distance | | Typical user | OEM / machine builders with their own air or rotary system | End-users and integrators who need a complete rotating nozzle ionizer | * Ionization range measured at standard conditions. Effective range may vary with ambient humidity, temperature and air pressure. ### Technical specifications | Parameter | Specification | |---|---| | Variants | SE-ARN-80-112-C3-AC01 (ionizing ring only) · SE-ARN-80-112-C3-PA (complete rotating nozzle) | | Compatible power unit | SE-PAC-80-2-C (2 outputs) · SE-PAC-80-4-C (4 outputs) — SE-PAC-55 is not compatible | | Ionization type | 8 kV AC — shockless | | Ionizing pin type | Tungsten — extremely long lifetime | | Rotary nozzle (PA) | Body ⌀ 70 mm, nozzle hole ⌀ 1.8 mm (FG-AC-0002) | | Pin current (safety) | < 250 μA; transformer current max. 5 mA (fused) | | Polarity | Alternating AC | | Operating temperature | Max. 60 °C | | Max. humidity | 70 % rH, non-condensing | | Protection class | IP66 — fully sealed | | Housing | Industrial-grade, impact-resistant | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | | Cable — C3 (standard) | 3 m HFFR-protected flex cable with HV connector | | Cable — C5 (option) | 5 m HFFR-protected flex cable with HV connector | | Cable — C12 (option) | 12 m HFFR-protected flex cable with HV connector | | Units per power unit | Up to 4 units per SE-PAC-80 power unit, within the 12 m total cable length per power unit | Variant-specific values (air connection, air consumption, ionization range, noise) are listed in the variant table above. ### Applications - Automotive headlights & lenses: Clean and ionize headlight reflectors, lens covers and optical assemblies before bonding or glazing — preventing dust inclusions and static-related adhesion failures on curved surfaces. - Plastic injection moulded parts: Neutralise intense post-demould static on complex 3D moulded components — seats, dashboards, covers and housings — before assembly or painting. - Machined plastic & composite parts: Remove cutting dust, swarf and machining residue from routed or milled parts before surface treatment or final inspection. - Automated cleaning stations on conveyors: Parts pass through the ring and are cleaned and ionized without stopping the production flow. - Robotic end-of-arm cleaning: The robot positions the ring around a part for a timed cleaning cycle before hand-off to the next process. - Pre-coating & pre-painting preparation: Ensure parts are free of static and dust immediately before entry into a paint booth or coating chamber — eliminating the major cause of coating defects. - Glass & film surface treatment: Remove static and particles from curved glass panels or film components before laminating, glazing or applying protective coatings. - Wood & furniture — CNC-machined parts: Eliminate cutting dust and static from routed wooden profiles and panels before lacquering or varnishing. Industries: Automotive (headlights, plastic body parts, optical components); Plastics & injection moulding (complex 3D moulded parts); Wood & furniture (CNC-machined profiles, pre-lacquering); Glass & optical industries; General manufacturing (pre-coating and pre-assembly); Electronics (robotic assembly lines). ### Complete system - SE-ARN-80-112-C3-AC01: Ionizing ring only — customer provides own air/nozzle system · 3 m cable (C5 / C12 also available) - SE-ARN-80-112-C3-PA: Complete unit with integrated rotating air nozzle · 3 m cable (C5 / C12 also available) - SE-PAC-80-2-C power unit: 2-output 8 kV AC power unit — required for both variants - SE-PAC-80-4-C power unit: 4-output 8 kV AC power unit — powers up to 4 units simultaneously - Compressed air (PA only): Dry, filtered compressed air — ⌀ 8 mm hose, 4 – 8 bar - Maintenance kit: FÖGE Antistatic Maintenance Kit — replacement tungsten pins and cleaning tools ### FAQ Q: What is the difference between the AC01 and PA variants? A: The AC01 is an ionizing ring with no air system — it neutralises static charges around the part but does not physically remove dust particles. It is designed for machine builders who already have their own rotary nozzle, air blow-off or cleaning mechanism. The PA is a complete, ready-to-use unit that integrates the ionizing ring with a pulsed air rotating nozzle — one unit provides both static neutralisation and dust removal. Q: Why does this product use 8 kV instead of 5.5 kV? A: The SE-ARN-80 is designed for parts with more demanding static charge levels — typically heavy plastic moulded parts, automotive components and machined materials where charges are high and the ionization distance to the part surface is greater. 8 kV delivers the ion density needed to neutralise these charges across the ring's working distance. Q: What power unit does the SE-ARN-80 require? A: The SE-ARN-80 requires an SE-PAC-80 power unit — available as SE-PAC-80-2-C (2 outputs) and SE-PAC-80-4-C (4 outputs). The SE-PAC-55 used with other FÖGE products is not compatible. Up to 4 units per power supply. Ordered separately. Q: Can multiple units be used together? A: Yes. Multiple SE-ARN-80 heads can be connected to a single SE-PAC-80-4-C power unit and synchronised for cleaning large or complex parts with multiple zones simultaneously. Q: Is the SE-ARN-80 suitable for mounting on a robotic arm? A: Yes. Both variants are designed for robotic arm mounting. Contact FÖGE for mounting bracket options for specific robot models. Q: What cable lengths are available? A: Three options: C3 (3 m standard), C5 (5 m) and C12 (12 m). The total cable length per SE-PAC-80 power unit must not exceed 12 m; the ring itself counts as 0 m. One ring can therefore be connected with the 12 m C12 cable, for example when the power unit is located at a distance from the installation point. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-arn-80-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-arn-80-manual-en.pdf - Dimensional drawing SE-ARN-80-112-C3-PA: https://foge-antistatic.com/downloads/drawings/foge-se-arn-80-112-c3-pa-dimensional-drawing-en.pdf - Dimensional drawing SE-ARN-80-112-AC01: https://foge-antistatic.com/downloads/drawings/foge-se-arn-80-112-ac01-dimensional-drawing-en.pdf ### 3D applications - Painting line with SE-ARN-80 air gate: https://foge-antistatic.com/applications/painting-gate-se-arn-80/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-painting-gate-se-arn-80-application-sheet-en.pdf) - Washer door robot cleaning with SE-ARN-80: https://foge-antistatic.com/applications/washer-door-robot-se-arn-80/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-washer-door-robot-se-arn-80-application-sheet-en.pdf) - Wood panel cleaning with SE-ARN-80: https://foge-antistatic.com/applications/wood-panel-cleaning-se-arn-80/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-wood-panel-cleaning-se-arn-80-application-sheet-en.pdf) ## SE-ACN Nozzle AC Antistatic Bar URL: https://foge-antistatic.com/products/static-electricity/dust-removal-cleaning/se-acn/ Category: Dust removal & cleaning · Family: Nozzle antistatic bars AC ionization plus high-velocity air jets — removes dust and separates static-stuck parts in one step. The FÖGE SE-ACN is a nozzle AC antistatic bar that combines high-voltage AC ionization with high-velocity compressed air jets from a row of nozzles along the bar body. It does two things at once: it neutralises the electrostatic charge on the target surface, and its focused air blast physically removes the dust and particles that the static was holding in place — or provides the force needed to separate parts that stick together. The SE-ACN is available in two voltage variants. The SE-ACN-55 operates at 5.5 kV with an SE-PAC-55 power unit; the SE-ACN-80 operates at 8 kV with an SE-PAC-80 power unit for heavily charged materials and larger working distances. Both variants use shockless AC technology, stainless steel emitter pins, a washable housing and a screened HFFR-protected cable with HV connector. Compressed air is required at the installation point. ### Key features - Dual action: AC ionization + high-velocity air jets from nozzles - Two voltage variants: SE-ACN-55 (5.5 kV) and SE-ACN-80 (8 kV) - Ionization + air range up to 600 mm - Effective at line speeds up to 500 m/min - Removes dust, particles and surface contamination - Air force separates static-stuck parts: sheet separation, mould release - Shockless design · stainless steel emitter pins - Washable design · screened HFFR-protected cable - Up to 4 bars per SE-PAC power unit ### How it works The SE-ACN connects to an SE-PAC AC high-voltage power unit (SE-PAC-55 for the SE-ACN-55, SE-PAC-80 for the SE-ACN-80) via its HV connector. The AC high voltage applied to the stainless steel emitter pins ionizes the surrounding air and generates a balanced cloud of positive and negative ions. Compressed air fed to the bar's air inlet flows through the manifold and out of a row of nozzles along the bar body, directing concentrated air jets at the target. At the target, the ions neutralise the surface charge and the air blast dislodges contaminants or provides the separation force. The alternating AC polarity neutralises positive and negative charges alike. ### Technical specifications | Parameter | Specification | |---|---| | Variants | SE-ACN-55-xxxx (5.5 kV) · SE-ACN-80-xxxx (8 kV) | | Compatible power unit | SE-ACN-55: SE-PAC-55-2-C / SE-PAC-55-4-C · SE-ACN-80: SE-PAC-80-2-C / SE-PAC-80-4-C | | Output | 5.5 kV (SE-ACN-55) · 8 kV (SE-ACN-80) | | Ionization type | High voltage AC — shockless | | Ionization + air range | Up to 600 mm | | Max. line speed | 500 m/min | | Ordering length | 100 – 2500 mm in 100 mm steps | | Air connection | 10 mm hose | | Air pressure — dry filtered air | 5 bar (8 bar max.) | | Emitter pin material | Stainless steel — long service life | | Cable | C2: 2 m HFFR-protected cable with HV connector | | Bars per power unit | Up to 4 per SE-PAC power unit, within 12 m total length of cables and bars | | Environment | 0 – 50 °C · max. 70 % rH | | Noise level | < 40 dBA | | Safety | Shockless, pin current < 250 μA · transformer current max. 5 mA (with fuse) | | Housing | Washable, industrial-grade | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | ### Applications - Printing press & sheet feeder — sheet separation: Neutralise the static that makes sheets cling together and blow the top sheet free for single-sheet feeding. - Injection moulding — mould release: Neutralise freshly moulded parts as they leave the mould while the air blast assists ejection and cleans the mould face. - Pre-print surface cleaning: Remove dust, fibres and particles from paper, film, board and plastic before printing. - Coating & laminating: Clean and neutralise substrates before coating or laminating. Industries: Printing & converting; Plastics & injection moulding; Packaging; Paper & board; Automotive (plastic parts); Electronics. ### Complete system - SE-ACN-55 or SE-ACN-80 bar (specify length): Choose the voltage variant and order the required length - SE-PAC-55-2-C / SE-PAC-55-4-C: Required for the SE-ACN-55 - SE-PAC-80-2-C / SE-PAC-80-4-C: Required for the SE-ACN-80 - Compressed air supply: Dry, filtered compressed air at 5 bar (8 bar max.) via 10 mm hose - SE-CAB-AC-1 extension cable (optional): Non-standard cable lengths in 1 m steps within the 12 m total length per power unit ### FAQ Q: What is the difference between the SE-ACN-55 and the SE-ACN-80? A: Both have the same air-blast cleaning and separation function. The SE-ACN-55 operates at 5.5 kV with an SE-PAC-55 power unit; the SE-ACN-80 operates at 8 kV with an SE-PAC-80 power unit for heavily charged materials and larger distances. Q: Is compressed air required? A: Yes. The air jets provide the cleaning and separation force. Use dry, filtered air at 5 bar (8 bar max.). Q: Can I use an SE-PAC-55 with the SE-ACN-80? A: No. The power unit voltage must match the bar: SE-PAC-55 for the SE-ACN-55, SE-PAC-80 for the SE-ACN-80. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-acn-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-acn-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-acn-dimensional-drawing-en.pdf ## SE-DCN-110 Pulsed DC Nozzle Antistatic Bar URL: https://foge-antistatic.com/products/static-electricity/dust-removal-cleaning/se-dcn/ Category: Dust removal & cleaning · Family: Nozzle antistatic bars Pulsed DC static elimination plus high-velocity air jets — dust removal, sheet separation and mould release from 24 V DC. The FÖGE SE-DCN is a pulsed DC nozzle antistatic bar that combines pulsed DC ionization with a row of high-velocity air nozzles along the bar body. Like the SE-ACN it is a dual-function device: it neutralises the electrostatic charge on the target surface and delivers a focused air blast — either to blow away the dust and particles the static was holding, or to provide the force needed to separate parts that stick together. The difference from the SE-ACN is the ionization technology. The SE-DCN generates its 11 kV pulsed DC ionization internally from a 24 V DC supply — no HV transformer, no HV cabling and no SE-PAC power unit. It connects to the SE-PSU-24-C-M12 power supply (sold separately) via an M12 connector, which makes it easy to integrate into machine controls, robotic installations and 24 V DC production lines. Compressed air is required at the installation point. ### Key features - Dual function: pulsed DC ionization + high-velocity air jets - 11 kV pulsed DC — no HV power unit required - 24 V DC supply via M12 connector (4-pin M12 cable) - Ionization range up to 600 mm - Removes dust and contamination or separates static-stuck parts - Tungsten emitter pins · shockless design - Signal LED for status display - Lengths from 300 to 2000 mm · IP66 ### How it works The SE-DCN connects to a 24 V DC supply via its M12 connector. The pulsed DC circuit inside the bar converts the 24 V input to high voltage and applies it to the tungsten emitter pins, alternating continuously between positive and negative pulses to produce a balanced stream of ions. Compressed air connected to the bar's air inlets flows through the manifold and out of focused nozzles along the bar body. At the target, the ions neutralise the charge and the air blast removes contamination or provides the separation force. ### SE-DCN or SE-ACN — which nozzle bar to choose | Parameter | SE-DCN (this product) | SE-ACN | |---|---|---| | Ionization | Pulsed DC, 11 kV | AC, 5.5 kV or 8 kV | | Power supply | 24 V DC (SE-PSU-24-C-M12) | SE-PAC-55 or SE-PAC-80 HV unit | | HV power unit | Not required | Required | | Connector | M12 (4-pin cable) | HV plug-and-play connector | | Air required | Yes | Yes | ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-DCN-110-xxxx-C | | Length for ordering | 300 – 2000 mm | | Operating voltage | 24 V DC (21 – 28 V) | | Power supply (sold separately) | SE-PSU-24-C-M12 (220 V AC to 24 V DC) | | Connector | M12, 5-pin — use a 4-pin M12 cable | | Ionization | Pulsed DC · 11 kV · shockless | | Ionization range | Up to 600 mm | | Air connection | 10 mm hose | | Air pressure — dry filtered air | 6 bar | | Emitter pin material | Tungsten — long life | | Status indication | Signal LED | | Mounting | M6 mounting bracket · ground terminal | | Polarity | Alternating pulsed DC — balanced ion output | | Environment | 0 – 55 °C · 70 % rH non-condensing max. · IP66, fully sealed (with suitable cable) | | Safety | Shockless, pin current < 250 μA | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | ### Applications - Printing press & sheet feeder — sheet separation: Neutralise static between sheets while the air blast separates the top sheet from the stack. - Injection moulding — mould release: Neutralise freshly moulded parts while the air blast assists ejection and cleans the mould face. - Pre-print & pre-coat surface cleaning: Remove dust, fibres and particles from paper, film, board and plastic before printing, coating or varnishing. - Pre-laminating & pre-bonding cleaning: Remove static and contamination before adhesive application, laminating or bonding. - Thermoformed part separation: Separate trays, blisters and packaging components that cling together. - Electronic component & PCB cleaning: Remove particles from PCBs and assemblies before assembly or inspection. Industries: Printing & converting; Plastics & injection moulding; Packaging & thermoforming; Electronics; Paper & board; Automotive (plastic parts). ### Complete system - SE-DCN bar (specify length): 300 – 2000 mm - SE-PSU-24-C-M12 power supply: 220 V AC to 24 V DC — required · sold separately - 4-pin M12 cable: Industrial M12 connection cable · sold separately - Compressed air supply: Dry, filtered air at 6 bar via 10 mm hose ### FAQ Q: What is the difference between the SE-DCN and the SE-ACN? A: Both bars ionize + clean and ionize + separate with the same nozzle principle. The SE-DCN uses 11 kV pulsed DC from a 24 V DC supply; the SE-ACN uses AC ionization from an SE-PAC HV power unit. Q: Does the SE-DCN require an SE-PAC power unit? A: No. The ionization is generated inside the bar from 24 V DC. The SE-PSU-24-C-M12 adapter is required and sold separately. Q: Which cable do I need? A: A 4-pin M12 cable. The device connector has 5 pins; the centre pin is reserved for factory programming and is not used by the 4-pin cable. Q: Is compressed air required? A: Yes. Use dry, filtered air at 6 bar through a 10 mm hose. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-dcn-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-dcn-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-dcn-dimensional-drawing-en.pdf ### 3D applications - Injection moulding with SE-DCN: https://foge-antistatic.com/applications/injection-moulding-se-dcn/ (application sheet: https://foge-antistatic.com/downloads/application-sheets/foge-app-injection-moulding-se-dcn-application-sheet-en.pdf) ## SE-PAC AC High Voltage Power Unit URL: https://foge-antistatic.com/products/static-electricity/power-units/se-pac/ Category: Power units · Family: AC high-voltage power units 5.5 kV or 8 kV AC power for up to 4 FÖGE antistatic bars and ionizers — compact, short-circuit protected, plug-and-play. The FÖGE SE-PAC is a compact, robust high voltage AC power unit that supplies FÖGE AC antistatic bars, nozzles and ionizing devices. Four models cover two voltage levels and two output configurations, so the SE-PAC is the central power source of every FÖGE AC static elimination system. It connects to a 220 V AC, 50 Hz mains supply and converts it to the high voltage required by the connected ionizing equipment. The compact housing fits into machine control panels and production line enclosures. The ON/OFF switch and power light allow operators to control and check the system at a glance. Short-circuit protection and a fuse protect the power unit and the connected bars against wiring faults. The HV output connectors match the HV connectors of all compatible FÖGE AC bars for fast connection and disconnection during installation and maintenance. ### Key features - Four models: SE-PAC-55-2-C · SE-PAC-55-4-C (5.5 kV) · SE-PAC-80-2-C · SE-PAC-80-4-C (8 kV) - 2 or 4 outputs — power up to 4 AC ionizing devices from one unit - 5.5 kV for SE-ACB-55, SE-ACA-55, SE-ACG, SE-ACIN-55 and SE-ACS-55-50 - 8 kV for SE-ACB-80, SE-ACA-80 and SE-ARN-80 - 220 V AC, 50 Hz mains supply - Short-circuit protection and F0.1AL250V fuse - ON/OFF switch and power light - Robust long-life transformer · compact design · IP54 ### How it works The SE-PAC connects to a 220 V AC, 50 Hz mains supply. Inside, a robust high-voltage transformer steps the mains voltage up to the AC high voltage output — 5.5 kV for the SE-PAC-55 models, 8 kV for the SE-PAC-80 models. The high voltage is delivered through the HV output connectors to the connected FÖGE AC antistatic bars, where it ionizes the air at the emitter pins and generates the positive and negative ions that neutralise static charges. The ON/OFF switch controls the unit and the power light shows when it is on. The short-circuit protection disconnects the output in the event of a short circuit; the fuse provides further protection. ### Which SE-PAC to choose | Parameter | SE-PAC-55-2-C | SE-PAC-55-4-C | SE-PAC-80-2-C | SE-PAC-80-4-C | |---|---|---|---|---| | Output voltage | 5.5 kV | 5.5 kV | 8 kV | 8 kV | | Number of outputs | 2 | 4 | 2 | 4 | | Compatible devices | SE-ACB-55 · SE-ACA-55 · SE-ACG · SE-ACIN-55 · SE-ACS-55-50 | SE-ACB-55 · SE-ACA-55 · SE-ACG · SE-ACIN-55 · SE-ACS-55-50 | SE-ACB-80 · SE-ACA-80 · SE-ARN-80 | SE-ACB-80 · SE-ACA-80 · SE-ARN-80 | ### Technical specifications | Parameter | Specification | |---|---| | Models | SE-PAC-55-2-C · SE-PAC-55-4-C (5.5 kV) · SE-PAC-80-2-C · SE-PAC-80-4-C (8 kV) | | Mains supply | 220 V AC · 50 Hz plug connection | | Panel | ON/OFF switch · power light · power connector | | Fuse | F0.1AL250V fast-blow glass fuse, 5 × 20 mm | | Safety | Short-circuit protection | | HV outputs | Metal screw-type HV connectors for FÖGE AC bars | | Additional earth connection | Recommended — connect separately | | Max. total length per power unit | 12 m of cables and devices connected (bar lengths count towards the total) | | Environment | 70 % rH non-condensing max. · location dry and oil-free | | Operating temperature | Max. 50 °C | | Protection class | IP54 | | Housing dimensions | 146 × 124 × 90 mm · base plate 170 mm, ⌀ 6 mm mounting holes | | EMC compliance | 2014/30/EU — EMC Directive | | Electrical safety | 2014/35/EU — Low Voltage Directive | ### Applications - Printing & converting: Central HV supply for AC bars on printing, laminating and slitting machines. - Plastics & film: Power AC bars on extrusion, winding and thermoforming lines. - Packaging: Supply AC bars and nozzles on form-fill-seal, labelling and laminating machines. - Automotive: Supply AC ionizers and ionizing rings for plastic panels and headlight components. Industries: Plastics & film; Printing & converting; Packaging; Textiles; Thermoforming & extrusion; Automotive (plastic panels, headlights); Paper & board. ### Complete system - SE-PAC power unit: Choose 5.5 kV (SE-PAC-55) or 8 kV (SE-PAC-80) and 2 or 4 outputs - Compatible FÖGE AC bars / devices: 5.5 kV: SE-ACB-55, SE-ACA-55, SE-ACG, SE-ACIN-55, SE-ACS-55-50 · 8 kV: SE-ACB-80, SE-ACA-80, SE-ARN-80 - SE-CAB-AC-1 extension cable (optional): Non-standard cable lengths in 1 m steps within the 12 m total length per power unit ### FAQ Q: Can I connect SE-ACB-55 and SE-ACB-80 bars to the same SE-PAC? A: No. The SE-PAC-55 models output 5.5 kV and supply only 5.5 kV devices. The SE-PAC-80 models output 8 kV and supply only 8 kV devices. Use separate power units for each voltage level. Q: Can I connect fewer devices than the number of outputs? A: Yes. Unused outputs simply stay unconnected. Q: Can I connect more than 4 bars to one SE-PAC? A: No. The 2-output models supply up to 2 devices, the 4-output models up to 4. Use additional SE-PAC units for more bars. Q: How long may the cables be? A: The total length of all devices and cables connected to one SE-PAC must not exceed 12 m. The length of the bars counts towards the total. Q: What happens if a bar short-circuits? A: The short-circuit protection disables the output. Switch the unit off, find and correct the fault in the bar or cable, then switch on again. If the switch is on but the light stays off, replace the F0.1AL250V fuse. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-pac-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-pac-manual-en.pdf - Dimensional drawing SE-PAC-55-2-C: https://foge-antistatic.com/downloads/drawings/foge-se-pac-55-2-c-dimensional-drawing-en.pdf - Dimensional drawing SE-PAC-55-4-C: https://foge-antistatic.com/downloads/drawings/foge-se-pac-55-4-c-dimensional-drawing-en.pdf - Dimensional drawing SE-PAC-80-2-C: https://foge-antistatic.com/downloads/drawings/foge-se-pac-80-2-c-dimensional-drawing-en.pdf - Dimensional drawing SE-PAC-80-4-C: https://foge-antistatic.com/downloads/drawings/foge-se-pac-80-4-c-dimensional-drawing-en.pdf ## SE-SFM-030 Static Electric Fieldmeter URL: https://foge-antistatic.com/products/static-electricity/measurement/se-sfm-030/ Category: Measurement · Family: Measuring instruments Handheld non-contact surface charge measurement up to 200 kV — two auto-selected ranges, polarity display, hold function. The FÖGE SE-SFM-030 is a precision handheld static electric fieldmeter for engineers, process technicians and quality managers who need to investigate, quantify and diagnose static electricity problems on industrial production lines. Static charge is invisible until it is strong enough to cause an operator shock — by which point it may already have caused dust contamination, coating failures, material misalignment or damage to electronic components. The SE-SFM-030 measures the electrostatic surface voltage on any non-conductive material at a fixed 100 mm distance, displaying the magnitude in volts and the polarity. The meter covers 0 to 200 kV across two automatically selected ranges: 0 – 20 kV with 10 V resolution, and 20 – 200 kV with 100 V resolution. Accuracy at calibration is ±5 %. A hold function freezes the reading when the measurement position is awkward. Battery-powered and fully portable, the SE-SFM-030 is supplied with a carrying case, battery and earth cord, and is the companion tool for installing, commissioning and troubleshooting any FÖGE static elimination system. ### Key features - Non-contact electrostatic surface voltage measurement at fixed 100 mm distance - Measurement range up to 200 kV — covers the full range of industrial static charges - Two auto-selected ranges: 0 – 20 kV (10 V resolution) and 20 – 200 kV (100 V resolution) - Polarity display — positive (+) or negative (−) - Hold function — freezes the reading for difficult measurement positions - Accuracy ±5 % at calibration - Battery-powered — fully portable, no mains supply needed - Supplied complete: carrying case, battery and earth cord - Compact handheld design ### How it works Static electricity is a coulombic charge — it forms a current when it moves, but is difficult to measure when stationary. The SE-SFM-030 measures surface voltage using Q = CV, where Q is the charge on the surface, C is the capacitance between the surface and the meter's sensor, and V is the voltage. Holding the meter at exactly 100 mm from the surface creates a constant, known capacitance. With C fixed, the voltage V varies in direct proportion to the charge Q. The sensor detects the electrostatic field at 100 mm without touching the surface, and the electronics display the corresponding surface voltage. The two measurement ranges switch automatically at the 20 kV threshold. ### How to use the SE-SFM-030 WARNING: Always connect the earth cord to a known ground point before taking measurements. An unearthed meter gives inaccurate readings. 1. Connect the earth cord to a known earth point (e.g. a grounded machine frame or earth terminal). 2. Switch the meter on and allow 30 seconds for the electronics to stabilise. 3. Hold the sensor end of the meter at exactly 100 mm from the surface to be measured. 4. Point the sensor directly at the surface — do not hold it at an angle. 5. Read the voltage and polarity from the display. Note both the sign (+ or −) and the magnitude. 6. If the reading position is awkward, press HOLD to freeze the display, then read the value from a comfortable position. 7. To map static distribution, take readings at multiple points across the surface, recording location and value for each. 8. To verify ionization effectiveness, measure before switching on the ionizing equipment, then again after — and compare. Tip: take at least three readings at each point and average the results. Surface charge can fluctuate slightly with humidity, temperature and material movement. ### Technical specifications | Parameter | Specification | |---|---| | Product code | SE-SFM-030 | | Measurement principle | Non-contact electrostatic field measurement at fixed 100 mm distance (Q = CV) | | Measurement distance | 100 mm — fixed, standardised distance | | Measurement range | 0 – 200,000 V (200 kV) — two auto-selected ranges | | Range 1 | 0 – 20 kV · resolution 10 V | | Range 2 | 20 – 200 kV · resolution 100 V | | Range selection | Automatic — no manual switching | | Accuracy | ± 5 % (at calibration) | | Calibration | On a 150 × 150 mm charge plate (other plate sizes on request, e.g. 450 × 450 mm) | | Drift | < 0.1 % in 10 s | | Polarity display | Positive (+) and negative (−) | | Hold function | Yes — freezes reading on display | | Display | 3½-digit LCD | | Power | 9 V PP3 battery — included; low-battery indicator; automatic switch-off after 60 s | | Supplied with | Carrying case · 9 V battery · earth lead · certificate of calibration | | Earth lead | 3 mm curly earth cord with crocodile clip / 4 mm bayonet connector | | Design | Handheld — portable | | Dimensions | 124 × 24 × 64 mm | | Weight | 175 g | | Construction | Anodised aluminium case, recessed stainless steel sensing plate | | Humidity | 70 % rH, non-condensing max. | | Certification | CE — EN-500081-1 (EMC), BS7506-2 (construction) | ### Applications - Diagnosing static problems: Investigate unexplained dust attraction, coating defects, material sticking or operator shocks by mapping static levels across the machine. - Commissioning ionization equipment: Verify that a newly installed ionizing bar, blower or nozzle is correctly positioned and neutralising to the required level before full production speed. - Setting acceptance standards: Establish measurable targets (e.g. surface charge below ±1 kV) that define acceptable performance for the ionization system. - Routine performance checks: Periodically measure static levels at key points to confirm that ionization equipment has not degraded. - Troubleshooting ESD events: Locate the source of electrostatic discharge events in electronics assembly or packaging lines. - Pre- and post-cleaning verification: Measure static before and after cleaning antistatic bars to confirm that cleaning has restored full ionization performance. - Material and process investigation: Characterise how much static a material, machine operation or process speed generates — to specify the correct ionization solution from the outset. Industries: Plastics & film (winding, converting, thermoforming, extrusion); Printing & converting; Packaging (sealing, labelling, form-fill-seal); Electronics & ESD-sensitive manufacturing; Automotive (plastic panels, paint booth investigation); Textiles; Pharmaceutical & medical (cleanroom charge control); Paper & board. ### Complete system - SE-SFM-030 fieldmeter: Handheld static electric fieldmeter - Carrying case: Protective case - Battery: Installed and ready - Earth cord: Grounds the meter for an accurate reference potential ### FAQ Q: Why must the meter be held at exactly 100 mm from the surface? A: The SE-SFM-030 measures surface voltage using Q = CV. At 100 mm, the capacitance C is a fixed, known value. Holding at a different distance changes C and makes the reading incorrect. Use the distance indicator on the meter or a 100 mm spacer gauge if precise positioning is difficult. Q: What does the polarity reading tell me? A: Whether the charge is positive or negative. This reveals how the charge is being generated — certain materials and processes consistently produce one polarity — and confirms that an AC ionizer is correctly neutralising the charge. Q: Why must I connect the earth cord? A: The earth cord grounds the meter, providing the reference potential needed for accurate measurement. Without it, the meter can float at an undefined potential and give unstable or incorrect readings. Q: Can the meter measure charge on conductive materials? A: The SE-SFM-030 is designed for non-conductive materials such as plastics, films, paper and textiles. Conductive materials normally drain charge to ground and show near-zero readings. Q: How often should the meter be calibrated? A: Annual calibration by a qualified service facility is recommended for instruments in regular use. Contact FÖGE for calibration service options. Q: Can I use the meter on a running production line? A: Yes. The SE-SFM-030 measures without contact at 100 mm. Maintain the correct distance and avoid contact with moving parts. For very high-speed webs, take readings from a fixed, stable position. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-sfm-030-datasheet-en.pdf - Instruction manual: https://foge-antistatic.com/downloads/manuals/foge-se-sfm-030-manual-en.pdf - Dimensional drawing: https://foge-antistatic.com/downloads/drawings/foge-se-sfm-030-dimensional-drawing-en.pdf ## SE-CLEAN Antistatic Products Maintenance Kit URL: https://foge-antistatic.com/products/static-electricity/accessories/se-clean/ Category: Accessories · Family: Maintenance Cleaning fluid and nylon brush for FÖGE antistatic bars, blowers, airguns and nozzles. Antistatic devices must be cleaned regularly to keep their efficiency. The strong electric field attracts airborne dust and contaminants, the ionization of the air causes carbon to build up on the electrodes, and in textile applications ink or fibres can contaminate the pins. Dirty emitter pins reduce efficiency and can cause circuit overload and short circuits. The FÖGE Antistatic Products Maintenance Kit contains a special cleaning fluid and a nylon brush. The fluid is non-conductive and water-free; it removes dust, carbon and dirt without damaging the product and evaporates without leaving any residue. The kit is designed for the maintenance of antistatic bars, air blowers, antistatic air guns and other antistatic devices. ### Key features - Non-conductive, water-free cleaning fluid — evaporates without residue - Removes dust, carbon deposits, ink and fabric residue from emitter pins - Nylon brush, 225 × 35 × 22 mm — cleans gently without damaging the pins - Spray head for direct application - For FÖGE AC and DC bars, blowers, airguns and nozzles ### How it works Switch the electrode off and do not switch it on again until it is dry. The cleaning fluid can be poured directly onto the electrode or applied with the spray head. The frequency of cleaning depends on the process and the environment. ### Usage instructions WARNING: Switch the electrode OFF and do not switch it ON again until it is dry. 1. Clean the static control device with the FÖGE cleaning brush. 2. Attach the spray head to the bottle containing the cleaning fluid. 3. Moisten a cloth with cleaning fluid and wipe the static control device, taking care around the emitters. 4. Repeat brushing and cleaning until the static control device is clean. 5. Polish the pins carefully with a dry cloth. ### Technical specifications | Parameter | Specification | |---|---| | Kit contents | Antistatic products maintenance liquid (bottle with spray head) + nylon cleaning brush | | Cleaning fluid | Non-conductive, water-free · solvent mixture, contains isoparaffins · free from halogenated and aromatic hydrocarbons · evaporates without residue · use undiluted | | Brush dimensions | 225 × 35 × 22 mm | | Brush filaments | Nylon, ⌀ 0.35 mm, 20 mm depth | | Compatible products | FÖGE AC and DC antistatic bars, air blowers, antistatic air guns and other antistatic devices | | Personal protection | Safety glasses · protective gloves | | Hazard statements | H304: May be fatal if swallowed and enters airways · H413: May cause long lasting harmful effects to aquatic life · EUH066: Repeated exposure may cause skin dryness or cracking | | Precautionary statements | P273 · P301 + P310 · P331 · P405 · P501 | ### Applications - Heavy dust — textile, woodworking, powder handling: Weekly or more often — inspect the pins every few days. - Printing and converting — ink, paper dust, adhesive: Weekly — after each production run if contamination is heavy. - Plastics and packaging — film, granules: Every 2 weeks — watch the pins for contamination build-up. - General manufacturing: Monthly — or whenever ionization performance visibly declines. - Electronics and cleanroom environments: Monthly to quarterly. - After any production incident: Immediately — especially after an ink spill, a dust cloud or unusual static behaviour. Industries: Printing & converting; Textiles; Plastics & packaging; Woodworking & powder handling; Electronics & ESD-sensitive manufacturing; Automotive; Food & beverage; Pharmaceutical & medical. ### Complete system - SE-CLEAN kit: One bottle of cleaning fluid with spray head and one nylon cleaning brush - Replacement fluid and brushes: Available separately — contact FÖGE ### FAQ Q: Do I need to rinse after cleaning? A: No. The fluid evaporates without leaving any residue. Wipe the surface with a clean cloth and let it dry before switching the device on again. Q: Can I clean a bar while it is switched on? A: No. Always switch the device off before cleaning and do not switch it on again until it is dry. Q: How do I know a bar needs cleaning? A: Reduced ionization range, uneven neutralisation across the bar, visible dust or discolouration on the pins, or increasing static problems on the line. ### Documents (PDF, English) - Datasheet: https://foge-antistatic.com/downloads/datasheets/foge-se-clean-datasheet-en.pdf